Resumo:
An improved method for the determination of phosphorus in natural waters, aquatic organisms and sediments by ignition method is proposed. The recoveries of phosphorus (P) from selected inorganic and organic P-containing compound standards after ignition with different auxiliaries, such as MgSO4, Mg(NO3)(2), MgO2, Mg(Ac-2) and CaCl2, were compared. We found that the phosphorus from most compound standards could not be completely recovered when these compounds were ignited (450-500degreesC) with the MgSO4 as auxiliary and the baked residue was extracted with 0.2 mol l(-1) HCl for 30min at 80degreesC or at room temperature. P recoveries, for example, were poor, less than 85%, if pyrophosphate and metaphosphate were ignited with the addition Of MgSO4 prior to the extraction of the baked residue with 0.2 mol l(-1) HCl at 80degreesC for 30 min. In contrast, MgO2, Mg(Ac)(2) and CaCl2, as well as Mg(NO3)(2), could all yield complete P recoveries at routine ashing temperatures (450-500degreesC). The results demonstrate that MgC12 is a more effective auxiliary agent for the determination of phosphorus in natural waters, aquatic organisms and sediments by ignition method than MgSO4 which is commonly used. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Phosphorus recoveries from selected inorganic and organic P-containing compounds after ignition with auxiliaries, such as MgSO4, Mg (NO3)(2), MgCl2, Mg (Ac)(2) and CaCl2 were studied. It was found that the phosphorus could not be completely recovered when most P-containing compounds were ignited with MgSO4 at temperature not higher than 500degreesC if the baked residue was extracted with 0.2 mol/L HCl for 30 min at 80degreesC or at room temperature. In contrast, MgCl2, Mg(Ac)(2) and CaCl2, as well as Mg(NO3)(2), could all yield complete P recoveries. We suggest that MgCl2 rather than MgSO4, which is usually used, should be utilized as ashing auxiliary agent in the P extraction by ignition method. Although Mg (NO3)(2) is a highly effective auxiliary agent, yet interference from MgSO4, danger of explosion, toxicity of nitrogen dioxide and more manipulation steps may limit its widespread utilization. It is suggested that if sediment is ignited with MgCl2, the extraction of residue with 0.2 mol/L HCl for 30 min at 80degreesC could give good result.
Resumo:
A pre-column derivatization method for the sensitive determination of aliphatic amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-ethyl chloroformate (BCEOC) followed by HPLC with fluorescence detection and APCI/NIS identification in positive-ion mode has been developed. The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent was replaced by the 1,2-benzo-3,4-dihydrocarbazole functional group, which resulted in a sensitive fluorescence derivatizing reagent, BCEOC, that could easily and quickly label amines. Derivatives were stable enough to be efficiently analyzed by HPLC and showed an intense protonated molecular ion corresponding m/z [M + H](+) with APCI/MS in positive-ion mode. The collision induced dissociation of the protonated molecular ion formed characteristic fragment ions at m/z 264.1, m/z 246.0 and m/z 218.1, corresponding to the cleavages of CH2CH2O-CO, CH2CH2-OCO, and N-CH2CH2O bonds. Studies on derivatization conditions demonstrated that excellent derivatization yields close to 100% were observed with a 3 to 4-fold molar reagent excess in acetonitrile solvent, in the presence of borate buffer (pH 9.0) at 40 degrees C for 10 min. In addition, the detection responses for BCEOC derivatives were compared with those obtained with CEOC and FMOC as labeling reagents. The ratios I-BCEOC/I-CEOC and I-BCEOC/I-FMOC were, respectively, 1.40-2.76 and 1.36-2.92 for fluorescence responses (here, I was the relative fluorescence intensity). Separation of the amine derivatives had been optimized on an Eclipse XDB-C-8 column. Detection limits calculated from an 0.10 pmol injection, at a signal-to-noise ratio of 3, were 18.65-38.82 fmol (injection volume 10 mu L for fluorescence detection. The relative standard deviations for intraday determination (n = 6) of standard amine derivatives (50 pmol) were 0.0063-0.037% for retention times and 3.36-6.93% for peak areas. The mean intra-and inter-assay precision for all amines were <5.4% and 5.8%, respectively. The recoveries of amines ranged from 96 to 113%. Excellent linear responses were observed with correlation coefficients of >0.9994. The established method provided a simple and highly sensitive technique for the quantitative analysis of trace amounts of aliphatic amines from biological and natural environmental samples.
Resumo:
A pre-column derivatization method for the sensitive determination of amines using a labeling reagent 2-(11H-benzo[a]-carbazol-11-yl) ethyl chloroformate (BCEC-Cl) followed by high-performance, liquid chromatography with fluorescence detection has been developed. Identification of derivatives was carried out by LC/APCI/MS in positive-ion mode. The chromophore of 1,2-benzo-3,4-dihydrocarbazole-9-ethyl chloroformate (BCEOC-Cl) reagent was replaced by 2-(11H-benzo[a]-carbazol-11-yl) ethyl functional group, which resulted in a sensitive fluorescence derivatizing reagent BCEC-Cl. BCEC-Cl could easily and quickly label amines. Derivatives were stable enough to be efficiently analyzed by HPLC and showed an intense protonated molecular ion corresponding m/z [M+ H](+) under APCI/MS in positive-ion mode. The collision-induced dissociation of the protonated molecular ion formed characteristic fragment ions at m/z 261.8 and m/z 243.8 corresponding to the cleavages of CH2O-CO and CH2-OCO bonds. Studies on derivatization demonstrated excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% were observed with three- to four-fold molar reagent excess. In addition, the detection responses for BCEC-derivatives were compared to those obtained using 1,2-benzo-3,4-dihydrocarbazole-9-ethyl chloroformate (BCEOC-Cl) and 9-fluorenyl methylchloroformate, (FMOC-Cl) as labeling reagents. The ratios I-BCEC/I-BCEOC = 1.94-2.17 and I-BCEC/I-FMOC = 1.04-2.19 for fluorescent (FL) responses (here, I was relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C-8 column. Detection limits calculated from 0.50 pmol injection, at a signal-to-noise ratio of 3, were 1.77-14.4 fmol. The relative standard deviations for within-day determination (n = 11) were 1.84-2.89% for the tested amines. The mean intra- and inter-assay precision for all amines levels were < 3.64% and 2.52%, respectively. The mean recoveries ranged from 96.6% to 107.1% with their standard deviations in the range of 0.8-2.7. Excellent linear responses were observed with coefficients of > 0.9996. (C) 2006 Elsevier B.V. All rights reserved.