207 resultados para Dual-Fuel PCCI


Relevância:

20.00% 20.00%

Publicador:

Resumo:

GaInP/GaAs dual-junction solar cell with a conversion efficiency of 25.2% has been fabricated using metalorganic chemical vapor deposition (MOCVD) technique. Quantum efficiencies of the solar cell were measured within a temperature range from 25 to 160A degrees C. The results indicate that the quantum efficiencies of the subcells increase slightly with the increasing temperature. And red-shift phenomena of absorption limit for all subcells are observed by increasing the cell's work temperature, which are consistent with the viewpoint of energy gap narrowing effect. The short-circuit current density temperature coefficients dJ (sc)/dT of GaInP subcell and GaAs subcell are determined to be 8.9 and 7.4 mu A/cm(2)/A degrees C from the quantum efficiency data, respectively. And the open-circuit cell voltage temperature coefficients dV (oc)/dT calculated based on a theoretical equation are -2.4 mV/A degrees C and -2.1 mV/A degrees C for GaInP subcell and GaAs subcell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was < 5 nM, and that of the MCCD was 0.1 mu M. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was <5 nM, and that of the MCCD was 0.1 μM. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative fast-ignition method is proposed involving the formation of a hot spot outside the precompressed fusion-fuel core by a series of shocks driven directly by the light pressure of laser pulses of increasing intensities. It is shown that a hot spot, which can be of different material from that of the fuel core, with temperature similar to 10 keV and density similar to 200 g/cm(2), can be formed. Being an electrically neutral plasma, the hot spot can easily be sent into the fuel core. (c) 2005 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key issues of engineering application of the dual gratings parallel matched interrogation method are expanding the measurable range, improving the usability, and lowering the cost by adopting a compact and simple setup based on existing conditions and improving the precision of the data-processing scheme. A credible and effective data-processing scheme based on a novel divisional look-up table is proposed based on the advantages of other schemes. Any undetermined data is belonged to a certain section, which can be confirmed at first, then it can be looked up in the table to correspond to microstrain by the scheme. It not only solves inherent problems of the traditional one (double value and small measurable range) but also enhances the precision, which improves the performance of the system. From the experimental results, the measurable range of the system is 525 mu epsilon, and the precision is +/- 1 mu epsilon based on normal matched gratings. The system works in real time, which is competent for most engineering measurement requirements. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel dual-slab laser with off-axis one-sided hybrid resonator is presented. The mode properties of the hybrid resonator are calculated using a fast Fourier transform method (FFT). The influence of wavefront distoration on the output beam quality is considered. Results indicate that the novel dual-slab laser is better than the normal dual-slab laser with off-axis one-sided hybrid resonator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we demonstrated a dual-wavelength competitive output in Nd:Y3SC1.5Al3.5O12 ceramic disk laser. Different dual-wavelength output behaviors for Nd:YSAG and Nd:YAG ceramic disk laser were investigated and discussed. By applying the energy transfer model, we suggested the reasonable explanation for this new phenomenon as the disordered replacing of Al3+ ions by Sc3+ ions. The main advantage of the dual-wavelength ceramic laser is the possibility to serve as the seed source to generate Terahertz radiation. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new dual-frequency laser displacement measurement interferometer with nanometer precision has been developed. An eight-pass optical subdivision technology is proposed to improve resolution based on commercial interferometers. A static positioning error measuring method has been used to examine the precision and repeatability of the laser interferometer. An optical resolution of 1.24 nm and an accuracy of nanometer scale have been achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The theory of optical subdivision techniques of dual-frequency laser interferometers is stated. And a novel optical subdivision technique is proposed originally to enhance resolution of a commercial interferometer by adding some corner-cubes. Then the performance of the interferometer is tested. The interferometer resolution of 1.24 nm and the average error of below 2 nm are achieved by using the technique. The most novel of the optical subdivision technique is without lambda/4 plates. It is less sensitive to environmental changes, it has prodigious potential to improve resolution farther and it can reduce polarization mixing error. (C) 2007 Elsevier GmbH. All rights reserved.