281 resultados para Double Sampling
Resumo:
We propose an atom localization scheme for a tripod-type atom making use of the sharp absorption peak resulting from interacting double-dark resonances. It is demonstrated that the probability of finding the atom at a particular position, as well as the localization precision, can be dramatically enhanced. The probability can be doubled by adjusting the Rabi frequency of the control field to the maximum Rabi frequency of the standing-wave field. Moreover, much better spatial resolution can be achieved for smaller detunings of the control and the standing-wave fields. (c) 2006 Optical Society of America.
Resumo:
We investigate the optical transmission properties of a combined system which consists of two quantum-dot-nanocavity subsystems indirectly coupled to a waveguide in a planar photonic crystal. A Mollow-like triplet and the growth of sidebands are found, reflecting intrinsic optical responses in the complex microstructure.
Resumo:
We address the influence of the orbital symmetry and the molecular alignment with respect to the laser-field polarization on laser-induced nonsequential double ionization of diatomic molecules, in the length and velocity gauges. We work within the strong-field approximation and assume that the second electron is dislodged by electron-impact ionization, and also consider the classical limit of this model. We show that the electron-momentum distributions exhibit interference maxima and minima due to electron emission at spatially separated centers. The interference patterns survive integration over the transverse momenta for a small range of alignment angles, and are sharpest for parallel-aligned molecules. Due to the contributions of the transverse-momentum components, these patterns become less defined as the alignment angle increases, until they disappear for perpendicular alignment. This behavior influences the shapes and the peaks of the electron-momentum distributions.
Resumo:
The single ionization of an He atom by intense linearly polarized laser field in the tunneling regime is studied by S- matrix theory. When only the first term of the expansion of the S matrix is considered and time, spatial distribution, and fluctuation of the laser pulse are taken into account, the obtained momentum distribution in the polarization direction of laser field is consistent with the semiclassical calculation, which only considers tunneling and the interaction between the free electron and external field. When the second term, which includes the interaction between the core and the free electron, is considered, the momentum distribution shows a complex multipeak structure with the central minimum and the positions of some peaks are independent of the intensity in some intensity regime, which is consistent with the recent experimental result. Based on our analysis, we found that the structures observed in the momentum distribution of an He atom are attributed to the " soft" collision of the tunneled electron with the core.
Resumo:
We describe the rigorous results of a wide-angle laser beam scanner, obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape is discussed. The distortion to the beam varies with the different relative angles of double prisms. The scanner expands the beam in some directions while it contracts the beam in other directions. According to the conservation of energy, the distribution of the laser intensity is changed as well. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
Resumo:
In this paper, we describe a wide-angle laser beam scanner and the rigorous result of the wide-angle laser beam scanner was obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape was discussed. The distortion of the beam shape is varying with the different relative angles of the double prisms. According to the conservation of the energy, the distribution of the laser intensity is changed too. (c) 2005 Elsevier GmbH. All rights reserved.
Resumo:
A new type of wave-front analysis method for the collimation testing of laser beams is proposed. A concept of wave-front height is defined, and, on this basis, the wave-front analysis method of circular aperture sampling is introduced. The wave-front height of the tested noncollimated wave can be estimated from the distance between two identical fiducial diffraction planes of the sampled wave, and then the divergence is determined. The design is detailed, and the experiment is demonstrated. The principle and experiment results of the method are presented. Owing to the simplicity of the method and its low cost, it is a promising method for checking the collimation of a laser beam with a large divergence. © 2005 Optical Society of America.
Resumo:
The general formulation of double refraction or internal double reflection for any directions of incidence and arbitrary orientation of the optic axis in a uniaxial crystal is analysed in terms of Huygens' principle. Then double refraction and double reflection along the sequential interfaces in a crystal are discussed. On this basis, if the parameters of the interface are chosen appropriately, the range of angular separation between the ordinary ray and extraordinary ray can be much greater, It is useful for crystal element design. Finally, as an example, an optimum design of the Output end interface for a 2 x 2 electro-optic switch is given.
Resumo:
A planar lightwave circuit (PLC) add-drop filter is proposed and analyzed, which consists of a symmetric Mach-Zehnder interferometer (MZI) combined with double microring resonators. A critical coupling condition is derived for a better box-like drop spectrum. Comparisons of its characteristics with other schemes, such as a MZI with a single ring resonator, arepresented, and some of the issues about device design and fabrication are also discussed.
Resumo:
In order to measure the diffraction-limit wavefront, we present three types of common-path double-shearing interferometers based on the theory of double shearing. Two pairs of half-aperture or whole-aperture wedge plates are used to introduce opposite tilt to realize the double-shearing function. By comparing the fringe widths in two fields, the marginal wavefront aberration can be obtained. In the paper, we give three different configurations: half-aperture configuration, whole-field configuration and double-interferometer configuration. The half-aperture configuration has the features of high sensitivity, stabilization and easy alignment. For the whole-field configuration, the interference fringes are displayed in two whole fields. Consequently, the divergent or convergent characteristic and aberration types of a wavefront can be identified visually. The whole-field configuration can be changed to the double-interferometer configuration for continuous test. Both small and large wavefront aberrations can be measured by the double-interferometer configuration. The minimum detectable wavefront aberration (W-0)(min) comes to 0.03 lambda. Lastly, we present the experimental results for the three types of double-shearing interferometers.
Resumo:
The original scanner for tilting orthogonal double prisms is studied to test the tracking performance in intersatellite laser communications. With a reduction ratio of more than 100 times from the change rate of the angle of beam deviation to that of the tilting angle of each prism, the theoretical analysis performed, as well as the verification experiment, indicates that the scanner can meet the requirements of the scanning accuracy superior to 0.5 mu rad with the scanning range greater than 500 mu rad and can facilitate the mechanical structure design. (c) 2006 Optical Society of America.
Resumo:
We describe the rigorous results of a wide-angle laser beam scanner, obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape is discussed. The distortion to the beam varies with the different relative angles of double prisms. The scanner expands the beam in some directions while it contracts the beam in other directions. According to the conservation of energy, the distribution of the laser intensity is changed as well. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
Resumo:
Because of high efficiencies, compact structure, and excellent heat dissipation, high-power fiber lasers are extremely useful for applications such as cutting, welding, precision drilling, trimming, sensing, optical transmitter, material processing, micromachining, and so on. However, the wavefront of the double clad fiber laser doped with ytterbium is still unknown. In this paper, wavefront of a fiber laser is measured and the traditional Hartmann-shack wavefront sensing method is adopted. We measured a double clad fiber laser doped with ytterbium which produces pulse wave output at infrared wavelength. The wavefront shape and contour are reconstructed and the result shows that wavefront is slightly focused and not an ideal plane wavefront. Wavefront measurement of fiber laser will be useful to improving the lasers' performance and developing the coherent technique for its applications.