44 resultados para Delay-Time


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigate the spectra of a femtosecond pulse train propagating in a resonant two-level atom (TLA) medium. it is found that higher spectral components can be produced even for a 2 pi femtosecond pulse train. Furthermore, the spectral effects depend crucially on both the relative shift phi and the delay time tau between the successive pulses of the femtosecond pulse train.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

研究了超短脉冲激光照射下LiF晶体的破坏机理及其超快动力学过程,利用扫描电镜和原子力显微镜等测试手段,观测了飞秒激光照射下LiF晶体的烧蚀形貌。利用烧蚀面积与激光脉冲能量的对数关系确定了LiF晶体的破坏阈值,并利用非线性玻璃棒展宽脉宽,得到了800nm激光作用下LiF破坏阈值对激光脉宽(50~1000fs)的依赖关系;利用抽运一探针超快探测平台,探测了LiF烧蚀过程中反射率的变化。采用雪崩击穿模型,并根据晶体材料反射率与材料的介电常量的依赖关系,通过数值计算,模拟了材料烧蚀阈值与脉宽的依赖关系及材料激发过

Relevância:

60.00% 60.00%

Publicador:

Resumo:

远场光学显微镜受衍射极限分辩率的限制,而近场光学显微镜由于缺乏层析能力,则无法实现超分辨的三维成像,研究了既可突破远场光学显微术的衍射极限分辨率又可实现三维成像的成像技术——受激发射损耗(STED),综述了STED的分辨率与STED光的光强,延迟时间、光斑空间分布等主要参数的关系,以及该技术的最新进展和应用前景。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The imaging technology of stimulated emission depletion (STED) utilizes the nonlinearity relationship between the fluorescence saturation and the excited state stimulated depletion. It implements three-dimensional (3D) imaging and breaks the diffraction barrier of far-field light microscopy by restricting fluorescent molecules at a sub-diffraction spot. In order to improve the resolution which attained by this technology, the computer simulation on temporal behavior of population probabilities of the sample was made in this paper, and the optimized parameters such as intensity, duration and delay time of the STED pulse were given.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

采用反射式达曼光栅建立了一种产生飞秒激光双脉冲的新装置.由于采用反射式结构,避免了材料色散和吸收导致的脉冲畸变,并构建了一台二次谐波一频率分辨光学开关装置对产生的双脉冲进行了测量.实验结果表明可以实现脉冲强度相等、时间宽度相同、不同间隔的双脉冲输出.产生双脉冲的装置在飞秒激光领域有着应用的价值.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

基于能量守恒和三波耦合波方程, 建立了超短脉冲在参变过程中二次谐波产生时的I类和II类相位匹配条件、基波与谐波之间的群速延迟时间、以及群速失配对晶体长度限制的理论基础。以负单轴非线性光学晶体CsLiB6O10为例, 分析和数值计算了超短脉冲宽度为100 fs时, 谐波的群速匹配长度随基波波长变化的规律。研究结果表明在I类相位匹配条件下, 基波波长为642 nm时, 群速延迟最小, 相应的群速匹配晶体长度最长为19.1 mm;在II类相位匹配条件下, 基波波长为767 nm, 群速延迟最小, 群速匹配长度最

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The femtosecond pump-probe technique was used to study the carrier dynamics of amorphous Ge2Sb2Te5 films. With carrier density at around 10(20)-10(21) cm(-3), carriers were excited within 1 ps and recovered to the initial state for less than 3 ns. On the picosecond time scale, the carrier relaxation consists of two components: a fast process within 5 ps and a slow process after 5 ps. The relaxation time of the fast component is a function of carrier density, which increases from 1.9 to 4.3 ps for the carrier density changing from 9.7x10(20) cm(-3) to 3.1x10(21) cm(-3). A possible interpretation of the relaxation processes is elucidated. In the first 5 ps the relaxation process is dominated by an intraband carrier relaxation and the carrier trapping. It is followed by a recombination process of trapped carriers at later delay time. (c) 2007 American Institute of Physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The pulse-shaping technique has found widespread applications in nonlinear optics and material processing. Experimental research on laser-induced plasma shutter to control the 532 nm pulse width is conducted. The impacts of the total pulse output energy on pulse compression are investigated, and a useful conclusion can be drawn that there exists an optimal value of pulse energy at which the shortest output pulse of 3.23 ns can be obtained without a device for delay-time. Once the device for delay-time is employed to change the optical differences between two laser paths, the pulse width can be further shortened to 1.51 ns. In short, the 1.5-12 ns width-tunable 532 nm laser pulses have been obtained by adopting the laser-induced plasma shutter technique. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Echolocation click events of a free-ranging juvenile and an adult finless porpoise (Neophocaena phocaenoides) were recorded with an acoustic data logger. Additionally, dive depth and swim speed of the juvenile were recorded with a behavior data logger. Echoes of echolocation signals from the water surface were clearly detected in shallow dives approximately less than 2 m. The delay time between a surface echo and a direct signal corresponded with the two-way transmission time for the animal's depth, indicating that the signals originated from the animal wearing the data loggers. The finless porpoises produced echolocation signals frequently and were thought to be able to detect their depth by listening to echoes from the water surface. (C) 2000 Acoustical Society of America. [S0001-4966(00)01609-X].

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Analytical expression of signal bandwidth of general straight and tapered N x N multimode interference (MMI) couplers is presented. The signal bandwidth is characterized as a function of mode relative energy, mode propagation delay time, and mode pulse broadening in the multimode section of MMI coupler. The model is used to evaluate the signal bandwidth of specific couplers. Results indicate that the signal bandwidth decreases seriously with the increase of channel number and channel guide space. Compared with the straight MMI coupler, the tapered MMI coupler has an improved signal bandwidth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Within the one-dimensional tight-binding model;rnd chi-3 approximation, we have calculated four-wave-mixing (FWM) signals for a semiconductor superlattice in the presence of both static and high-frequency electric fields. When the exciton effect is negligible, the time-periodic field dynamically delocalizes the otherwise localized Wannier-Stark states, and accordingly quasienergy band structures are formed, and manifest in the FWM spectra as a series of equally separated continua. The width of each continuum is proportional to the joint width of the valence and conduction minibands and is independent of the Wannier-Stark index. The realistic homogeneous broadening blurs the continua into broad peaks, whose line shapes, far from the Lorentzian, vary with the delay time in the FWM spectra. The swinging range of the peaks is just the quasienergy bandwidth. The dynamical delocalization (DDL) also induces significant FWM signals well beyond the excitation energy window. When the Coulomb interaction is taken into account, the unequal spacing between the excitonic Wannier-Stark levels weakens the DDL effect, and the FWM spectrum is transformed into groups of discrete lines. Strikingly, the groups are evenly spaced by the ac field frequency, reflecting the characteristic of the quasienergy states. The homogeneous broadening again smears out the line structures, leading to the excitonic FWM spectra quite similar to those without the exciton effect. However, all these features predicted by the dynamical theory do not appear in a recent experiment [Phys. Rev. Lett. 79, 301 (1997)], in which, by using the static approximation the observed Wannier-Stark ladder with delay-time-dependent spacing in the FWM spectra is attributed to a temporally periodic dipole field, produced by the Bloch oscillation of electrons in real space. The contradiction between the dynamical theory and the experiments is discussed. In addition, our calculation indicates that the dynamical localization coherently enhances the time-integrated FWM signals. The feasibility of using such a technique to study the dynamical localization phenomena is shown. [S0163-1829(99)10607-6].

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Scan test can be inserted around hard IP cores that have not been designed with DFT approaches. An 18x18 bits Booth Coding-Wallace Tree multiplier has been designed with full custom approach with 0.61 m CMOS technology. When we reuse the multiplier in another chip, scan chain has been inserted around it to increase the fault coverage. After scan insertion, the multiplier needs 4.7% more areas and 24.4% more delay time, while the fault coverage reaches to 95%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The hydraulic conductivity function of fractures is a key scientific question to describe and reveal the process and the role of water seepage reasonably. In this paper, the generation technology of random fracture network and the latest numerical computation method for equivalent permeability tensor of fracture network are applied to analyze the landslide located at Wangjiayuanzi in Wanzhou District of Chongqing by simulating the changes of the seepage field caused by the running of the Three Gorges Reservoir. The influences of the fracture seepage on the seepage field and stability of the landslide were discussed with emphasis. The results show that the fractures existing in the soil increase the permeability coefficient of the landslide body and reduce the delay time of the underground water level in the landslide which fluctuates relative to the water level of reservoir,that causes the safe coefficient of the slope changes more gently than that of the same slope without fractures. It means, if only water level fluctuating condition is concerned, the fractures existing in the soil plays a positive role to the stability of slopes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A LIBS setup was built in the Institute of Modern Physics. In our experiments, LIBS spectra produced by infrared radiation of Nd : YAG nanosecond laser with 100 and 150 mJ pulse energy, respectively, were measured by fiber optic spectrometer in the ranges of 230-430 run and 430-1080 nm with a delay time of 1.7 and gate width of 2 ms for potato and lily samples prepared by vacuum freeze-dried technique. The lines from different metal elements such as K, Ca, Na, Mg, Fe, Al, Mn and Ti, and nonmetal elements such as C, N, O and H, and some molecular spectra from C-2, CaO, and CN were identified according to their wavelengths. The relative content of the six microelements, Ca, Na, K, Fe, Al, and Mg in the samples were analyzed according to their representative line intensities. By comparison we found that there are higher relative content of Ca and Na in lily samples and higher relative content of Mg in potato samples. The experimental results showed that LIBS technique is a fast and effective means for measuring and comparing the contents of microelements in plant samples.