32 resultados para DINUCLEOTIDE
Resumo:
The electrooxidation polymerization of phenothiazine derivatives, including azure A and toluidine blue 0, has been studied at screen-printed carbon electrodes in neutral phosphate buffer. Both compounds yield strongly adsorbed electroactive polymer with reversible behavior and formal potentials closed to 0.04 V at pH 6.9. The modified electrodes exhibited good stability and electrocatalysis for NADH oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 500 mV lower than that of the bare electrodes. Further, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5-100 muM.
Resumo:
Electrooxidation of thionine on screen-printed carbon electrode gives rise to the modification of the surface with amino groups for the covalent immobilization of enzymes such as horseradish peroxidase (HRP). The biosensor was constructed using multilayer enzymes which covalently immobilized onto the surface of amino groups modified screen-printed carbon electrode using glutaraldehyde as a bifunctional reagent. The multilayer assemble of HRP has been characterized with the cyclic voltammetry and the faradaic impedance spectroscopy. The H2O2 biosensor exhibited a fast response (2 s) and low detection limit (0.5 muM).
Resumo:
The electrooxidation polymerization of azure B on screen-printed carbon electrodes in neutral phosphate buffer was studied. The poly(azure B) modified electrodes exhibited excellent electrocatalysis and stability for dihydronicotinamide adenine dinucleotide (NADH) oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 400 mV lower than that at the bare electrodes. Different techniques, including cyclic voltammetry, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy have been employed to characterize the poly (azure B) film. Furthermore, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5 muM to 100 muM.
Resumo:
The carbon nanotubes (CNTs) based microelectrode (ME) by modifying CNTs-room temperature ionic liquid (IL) gel at carbon fiber microelectrode (CFME) is easily prepared, which exhibits the typical cyclic voltammogram of ME with sigmoid shape and possesses good stability, high conductivity and enlarged current response and tunable dimension. The direct electron transfer of glucose oxidase has been greatly promoted showing reversible electrochemical behavior even at high scan rate. In addition, the CNTs based ME also exhibits effectively electrocatalytic oxidized ability to biomolecules, e.g. dopamine (DA), ascorbic acid (AA) and dihydronicotinamide adenine dinucleotide. The obvious separation of oxidized peak potential for DA and AA makes it possible to selectively determine DA in presence of AA. These phenomena show that the CNTs based ME has promising potential to detect various species in vivo and in vitro.
Resumo:
A poly(thionine) modified screen-printed carbon electrode has been prepared by an electrooxidative polymerization of thionine in neutral phosphate buffer. The modified electrodes are found to give stable and reproducible electrocatlytic responses to NADH and exhibit good stability. Several techniques, including cyclic voltammetry, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM), have been employed to characterize the poly(thionine) film. Further, the modified screen-printed carbon electrode was found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 5-100 muM.
Resumo:
Stable lipid film was made by casting dipalmitoylphosphatidylcholine (DPPC) and rutin onto the surface of a glassy carbon (GC) electrode. The electrochemical behavior of rutin in the DPPC film was studied. The modified electrode coated with rutin gave quasi-reversible reduction-oxidation peak on cyclic voltammogram in the phosphate buffer (pH 7.4). The peak current did not decrease apparently after stored at 4 degreesC for 8 hours in refrigerator. This model of biological membrane was used to investigate the oxidation of dihydronicotinamide adenine dinucleotide (NADH) by rutin. Rutin in the film acts as a mediator. The modified electrode shows a great enhancement and the anodic peak potential was reduced by about 220 mV in the oxidation of 5 X 10(-3) mol L-1 NADN compared with that obtained at a bare glassy carbon electrode. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
Stable lipid film was made by casting lipid in chloroform onto a glassy carbon electrode. This model of a biological membrane was used to investigate the oxidation of dihydronicotinamide adenine dinucleotide (NADH) by dopamine. After this electrode had been immersed in dopamine solution for 10 h, it was found that some dopamine had been incorporated in the film. The cyclic voltammogram was obtained for the oxidation of 2.0 X 10(-3) mol 1(-1) NADH with dopamine incorporated in the films. All electrochemical experiments were performed in 0.005 mol 1(-1) phosphate buffer (pH 7.0) containing 0.1 mol 1(-1) NaCl without oxygen. The oxidation current increased gradually with successive sweeps and reached steady state. It was a different phenomenon from previous results. The anodic overpotential was reduced by about 130 mV compared with that obtained at a bare glassy carbon electrode. The diffusion coefficient for 2.0 X 10(-3) mol 1(-1) NADH was 6.7 X 10(-6) cm(2) s(-1). (C) 1999 Elsevier Science S.A. All rights reserved.
Resumo:
The electrochemical behavior of flavine adenine dinucleotide (FAD) at a gold electrode involving adsorption of the reduced form FADH(2) and desorption of the oxidized form FAD has been studied by using electrochemical quartz crystal microbalance (EQCM). EQCM can present information not only about the electrochemical behavior but also about the mass changes on the electrode surface. The electrochemical properties and frequency shifts were investigated in FAD solutions at different pH values, concentrations and scan rates. Reversible voltammograms were observed when pH<4.5 and irreversible voltammograms were found when pH greater than or equal to 4.5. It is found to be a diffusion controlled process when the concentration of FAD is lower than 2x10(-4) moll(-1) (pH 1.5). On the contrary, at concentrations higher than 2x10(-4) moll(-1) (pH 1.5), it is found to be an adsorption controlled process.
Resumo:
In situ electrochemical scanning tunneling microscopy (ECSTM) has been employed to follow the renewal process of a graphite electrode accompanied by flavin adenine dinucleotide (FAD) electrochemical reaction which involves adsorption of the reduced form (FADH(2)) and desorption of the oxidized form (FAD). The renewal process initiates from steps or kinks on the electrode surface, which provide high active sites for adsorption. This renewal depends on the working electrode potential, especially in the range near the FAD redox potential. Our experiment suggests that delamination of the graphite surface is caused by interaction between the substrate and adsorbed molecules. A simple model is proposed to explain this phenomenon.
Resumo:
Twelve mediators have been modified by adsorption onto the paraffin impregnated graphite electrodes (IGE). The resulting electrodes exhibit electrocatalytic activity of different degrees towards oxidation of 1,4-dihydronicotinamide adenine dinucleotide (NADH). The electrocatalytic ability of the chemically modified electrode (CME) depends mainly on the formal potential and molecular structure of mediator. The formation of the charge transfer complex between NADH and adsorbed mediator has been demonstrated by the experiments using a rotating disk electrode. An electrocatalytic scheme obeying Michaelis-Menten kinetics has been confirmed, and some kinetic parameters were estimated. The solution pH influences markedly the electrocatalytic activity of the modified electrode. Various possible reasons are discussed.
Resumo:
The electrocatalytic oxidation of NADH by ferrocene derivatives and the influence of complexation with beta-cyclodextrin (beta-CD) were investigated at a microdisk electrode in a buffer solution. The cyclic voltammetric behavior of the ferrocene derivatives on the microdisk electrode was used to determine the electron-transfer rate constant from NADH to the ferricinium species. The heterogeneous rate constants and the diffusion coefficient of ferrocene derivatives were determined with the microdisk electrode. The effect of temperature and pH on the electrocatalytic oxidation of NADH were assessed.
Resumo:
Chemically modified electrodes (CMEs) were prepared by adsorbing different dyes, including methylene blue (MB), toluidine blue (TB) and brilliant cresyl blue (BCB), onto glassy carbon electrodes (GCE) with anodic pretreatment. The electrochemical reactions of adsorbed dyes are fairly reversible at low coverages. The CMEs are more stable in acid solutions than in alkaline ones, which is mainly due to decomposition of the dyes in the latter media. They exhibit an excellent catalytic ability for the oxidation of nicotinamide coenzymes (NADH and NADPH). The formation of a charge transfer complex between the coenzyme and the adsorbed mediator has been demonstrated using a rotating disk electrode. The charge transfer complex decomposition is a slow step in the overall electrode reaction process. Some kinetic parameters are estimated. Dependence of the electrocatalytic activity of the CMEs on the solution pH is discussed.
Resumo:
G chemically modified electrode (CME) was prepared by electrochemical copolymerization of pyrrole and Methylene Blue. The resulting CME exhibits effective electrocatalytic activity towards the oxidation of reduced nicotinamide coenzymes (NADH and NADPH),
Resumo:
Chemically modified electrodes with Methylene Green adsorbed on the graphite surface and incorporated into carbon paste exhibit excellent electrocatalytic ability for oxidation of NADH. Alcohol dehydrogenase, nicotinamide adenine dinucleotide (NAD+) and m
Resumo:
Through random sequencing, we found a total of 884000 base-pairs (bp) of random genomic sequences in the genome of Chinese shrimp (Fenneropenaeus chinensis). Using bio-soft Tandem Repeat Finder (TRF) software, 2159 tandem repeats were found, in which there were 1714 microsatellites and 445 minisatellites, accounting for 79.4% and 20.6% of repeat sequences, respectively. The cumulative length of repeat sequences was found to be 116685 bp, accounting for 13.2% of the total DNA sequence; the cumulative length of microsatellites occupied 9.78% of the total DNA sequence, and that of minisatellites occupied 3.42%. In decreasing order, the 20 most abundant repeat sequence classes were as follows: AT (557), AC (471), AG (274), AAT (92), A (56), AAG (28), ATC (27), ATAG (27), AGG (18), ACT (15), C (11), AAC (11), ACAT (11), CAGA (10), AGAA (9), AGGG (7), CAAA (7), CGCA (6), ATAA (6), AGAGAA (6). Dinucleotide repeats, not only in the aspect of the number, but also in cumulative length, were the preponderant repeat type. There were few classes and low copy numbers of repeat units of the pentanucleotide repeat type, which included only three classes: AGAGA, GAGGC and AAAGA. The classes and copy numbers of heptanucleotide, eleven-nucleotide and thirteen-nucleotide primer-number-composed repeats were distinctly less than that of repeat types beside them.