18 resultados para D stability
Resumo:
Cp3Yb (Cp = C5H5) reacts with a-naphthol (HNP) in THF to form Cp2Yb(NP)(THF) (1), which crystallizes in the space group P2(1)/n with unit cell dimensions a = 8.084(2), b = 15.996(6), c = 15.973(7) angstrom, beta = 98.95(3), V = 2040.3 angstrom and D(calc.) = 1.69 g cm-3 for Z = 4. Least-squares refinement based on 2242 observed reflections converged to a final R value of 0.081. The average Yb-C(Cp) distance is 2.60(2) angstrom and Yb-O(THF) and Yb-O(NP) distances are 2.30(1) and 2.06(1) angstrom, respectively. The title compound loses the coordinated THF molecule readily by heating under vacuum to give dimeric [Cp2Yb(NP)]2 (2), which undergoes disproportionation to give Cp3Yb and Yb(NP)3 on heating above 230-degrees-C.
Resumo:
A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.