23 resultados para Collection based art works
Resumo:
Novel compact design for 4-channel SOI-based reconfigurable optical add/drop multiplexer using microring resonators is presented and analyzed. Microring resonators have two important attributes as a key new technology for future optical communications, namely functionality and compactness. Functionality refers to the fact that a wide range of desirable filter characteristics can be synthesized by coupling multiple rings. Compactness refers the fact that ring resonators with radii about 30 mu m can lead to large scale integration of devices with densities on the order of 10(4) similar to 10(5) devices per square centimeter. A 4-channel reconfigurable optical add/drop multiplexer comprises a grid-like array of ridge waveguides which perpendicularly cross through each other. SOI-based resonators consisted of multiple rings at each of the cross-grid nodes serve as the wavelength selective switch, and they can switch an optical signal between two ports by means of tuning refractive index of one of the rings. The thermo-optic coefficient of silicon is 1.86x 10(-4) /K. Thus a temperature rise of 27K will increase the refractive index by 5 x 10(-3), which is enough to cause the switching of our designed microring resonators. The thermo-optic effect is used to suppress the resonator power transfer, rather than to promote loss. Thus, the input signal only suffers small attenuation and simultaneously low crosstalk can be achieved by using multiple rings.
Resumo:
The environment temperature has inevitable effects on property of the convect ion-based tilt sensors. It not only redefines the application, but also prevents the improvement of the sensor performance. Numerical simulation of the fluid flow in the chamber of a sensor was performed and the influence of the environment temperature was studied in this paper. At zero tilt angle, the temperature distribution along the perpendicular line cross the heat source at various environment temperatures was presented. It was found that the flow varied dramatically at different environment temperatures, which would cause the output signal vary accordingly, even when the tilt angle was kept at a constant, because this device works by sensing the change of flow. At the same condition, we present the numerical results when the temperature difference across the heat source and the environment was kept at the same, in those results, it was found that the temperature difference at every point along the perpendicular line cross the heat source keep the same, this result confirms the similarity principle of nature convection. Second, A method of eliminating environment temperature infect on property of convect ion-based tilt sensor, which is based on the theory of flow similarity, is proposed. It was found that a thermal transistance can be piped on the circuit of heat source to compensate the temperature of the heat source. A compensative circuit was specially designed which can keep flow similarity by changing heat source temperature in order to eliminate the influence of environment temperature. The experiment results show that above 70% temperature drift can be eliminated by this compensative circuit.
Resumo:
We present a universal analyzer for the three-particle Greenberger-Horne-Zeilinger (GHZ) states with quantum nondemolition parity detectors and linear-optics elements. In our scheme, all of the three-photon GHZ states can be discriminated with nearly unity probability in the regime of weak nonlinearity feasible at the present state of the art experimentally. We also show that our scheme can be easily extended to the analysis of the multi-particle GHZ states.
Resumo:
A new 2-D quality-guided phase-unwrapping algorithm, based on the placement of the branch cuts, is presented. Its framework consists of branch cut placing guided by an original quality map and reliability ordering performed on a final quality map. To improve the noise immunity of the new algorithm, a new quality map, which is used as the original quality map to guide the placement of the branch cuts, is proposed. After a complete description of the algorithm and the quality map, several wrapped images are used to examine the effectiveness of the algorithm. Computer simulation and experimental results make it clear that the proposed algorithm works effectively even when a wrapped phase map contains error sources, such as phase discontinuities, noise, and undersampling. (c) 2005 Society of Photo-Optical Instrumentation Engineers.
Resumo:
A new 2-D quality-guided phase-unwrapping algorithm, based on the placement of the branch cuts, is presented. Its framework consists of branch cut placing guided by an original quality map and reliability ordering performed on a final quality map. To improve the noise immunity of the new algorithm, a new quality map, which is used as the original quality map to guide the placement of the branch cuts, is proposed. After a complete description of the algorithm and the quality map, several wrapped images are used to examine the effectiveness of the algorithm. Computer simulation and experimental results make it clear that the proposed algorithm works effectively even when a wrapped phase map contains error sources, such as phase discontinuities, noise, and undersampling. (c) 2005 Society of Photo-Optical Instrumentation Engineers.
Resumo:
An FFT-based two-step phase-shifting (TPS) algorithm is described in detail and implemented by use of experimental interferograms. This algorithm has been proposed to solve the TPS problem with random phase shift except pi. By comparison with the visibility-function-based TPS algorithm, it proves that the FFT-based algorithm has obvious advantages in phase extracting. Meanwhile, we present a pi-phase-shift supplement to the TPS algorithm, which combines the two interferograms and demodulates the phase map by locating the extrema of the combined fringes after removing the respective backgrounds. So combining this method and FFT-based one, one could really implement the TPS with random phase shift. Whereafter, we systematically compare the TPS with single-interferogram analysis algorithm and conventional three-step phase-shifting one. The results demonstrate that the FFT-based TPS algorithm has a satisfactory accuracy. At last, based on the polarizing interferometry, a schematic setup of two-channel TPS interferometer with random phase shift is suggested to implement the simultaneous collection of interferograms. (c) 2007 Elsevier GrnbH. All rights reserved.
Resumo:
Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.