99 resultados para Antenna measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a measurement of flow patterns and flow velocities of gas-water two-phase flows based on the technique of electrical resistance tomography (ERT) in a 40m horizontal flow loop. A single-plane and dual-plane ERT sensor on conductive ring technique were used to gather sufficient information for the implementation of flow characteristics particularly flow pattern recognition and air cavity velocity measurement. A fast data collection strategy was applied to the dual-plane ERT sensor and an iterative algorithm was used for image reconstruction. Results, in respect to flow patterns and velocity maps, are reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluid transportation in microfluidic system could be benefit from the slip on solid-liquid interface. Slip length on many kinds of hydrophilic/hydrophobic surfaces have been measured recently. The two common-used experimental methods for boundary slip measurement include: (1) surface force measurement, such as surface force apparatus (SFA), atom force microscope (AFM), and (2) velocity measurement, like microPIV/PTV (Particle image velocimetry / Particle tracking velocimetry), total internal reflection velocimetry (TIRV). However, the measured results are rather scattered, larger measured slip lengths were reported by microPIV/PTV experiments. In this paper, we will investigate the deviations of the measured slip length on smooth hydrophilic surface. After measuring detailed velocity profiles very close to hydrophilic glass wall, we give a discussion on the effects influencing the slip measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In near wall measurements with microPIV/PTV, whether seeding particles can be effectively used to detect local fluid velocity is a crucial problem. This talk presents our recent measurements in microchannels [1][2]. Based on measured velocity profiles with 200nm and 50nm in pure water, we found that the measured velocity profiles are agreed with the theoretical values in the middle of channel, but large deviations between measured data and theoretical prediction appear close to wall (0.25mm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain the distribution rules of in situ stress and mining-induced stress of Beiminghe Iron Mine, the stress relief method by overcoring was used to measure the in situ stress, and the MC type bore-hole stress gauge was adopted to measure the mining-induced stress. In the in situ stress measuring, the technique of improved hollow inclusion cells was adopted, which can realize complete temperature compensation. Based on the measuring results, the distribution model of in situ stress was established and analyzed. The in situ stress measuring result shows that the maximum horizontal stress is 1.75-2.45 times of vertical stress and almost 1.83 times of the minimum horizontal stress in this mineral field. And the mining-induced stress measuring result shows that, according to the magnitude of front abutment pressure the stress region can be separated into stress-relaxed area, stress-concentrated area and initial stress area. At the -50 m mining level of this mine, the range of stress-relaxed area is 0-3 m before mining face; the range of stress-concentrated area is 3-55 m before mining face, and the maximum mining-induced stress is 16.5-17.5 MPa, which is 15-20 m from the mining face. The coefficient of stress concentration is 1.85.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an entanglement purification protocol for photonic mixed entangled states based on the two-mode polarization nondemolition parity detectors. Without the use of the controlled-NOT (CNOT) operations, the efficiency of our protocol can nearly approach that of the CNOT protocol. The total successful probability of our protocol can be nearly enhanced to the quantity twice as large as that of the linear-optics-based protocol. Besides, our protocol adopts common photon detectors rather than the sophisticated single-photon detectors required in the linear-optics-based protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyse further the entanglement purification protocol proposed by Feng et al. (Phys. Lett. A 271 (2000) 44) in the case of imperfect local operations and measurements. It is found that this protocol allows of higher error threshold. Compared with the standard entanglement purification proposed by Bennett et al. [Phys. Rev. Lett. 76 (1996) 722], it turns out that this protocol is remarkably robust against the influences of imperfect local operations and measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a mixed entanglement distillation protocol by means of the parity measurement of qubits. Without the use of controlled-NOT (CNOT) operations, the efficiency of our protocol can approach that of the CNOT protocol. In comparison, the total successful probability of our protocol can reach a quantity twice as large as that of the linear optics-based protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Illumination of an optically levitated particle with an intensity-modulated transverse beam induces a transverse vibration of a particle in an optical trap. Based on this, the trapping force of a trap can be measured. Using an intensity-modulated longitudinal levitating beam causes a particle to move vertically, allowing for the determination of some aerodynamic parameters of a particle in air. The principles and the experimental phenomena are described and the initial results are given. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gain of a transmitter for intersatellite communications is closely related to the performance of all the links. We calculate the transmitter telescope's gain with the help of the rigorous scalar diffraction theory and equivalent optical layout method. Furthermore, a comparison is performed with the conventional imaging method. The results show that the stop inside the telescope can affect the gain of the telescope. Finally, the gain is calculated under the condition of the aberrations. We find that different aberrations cause different effects. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gain of a transmitter for intersatellite communications is closely related to the performance of all the links. We calculate the transmitter telescope's gain with the help of the rigorous scalar diffraction theory and equivalent optical layout method. Furthermore, a comparison is performed with the conventional imaging method. The results show that the stop inside the telescope can affect the gain of the telescope. Finally, the gain is calculated under the condition of the aberrations. We find that different aberrations cause different effects. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method for measuring the radius of curvature of laser beams is introduced. It has been developed to estimate the astigmatic aberration of a diode laser. Compared with the interferornetry, this method is convenient and straightforward. (c) 2005 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total integrated scattering (TIS) measurement was performed to investigate the surface and volume scattering of K9 glass substrates with low reflectance. Ag layers with thicknesses of 60 nm were deposited on the front and back surfaces of the K9 glass substrates by the magnetron sputtering technique. Surface scattering of the K9 glass substrate was obtained by the TIS measurement of the Ag layers on the assumption that the Ag layers and the K9 substrate had the same surface profile. Volume scattering of the substrates was deduced by subtracting the front and back surface scattering from the total scattering of the substrates. (c) 2005 Optical Society of America.