150 resultados para Al 2O 3


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The acid-base stabilities of Al-13 and Al-30 in polyaluminum coagulants during aging and after dosing into water were studied systematically using batch and flow-through acid-base titration experiments. The acid decomposition rates of both Al-13 and Al-30 increase rapidly with the decrease in solution pH. The acid decompositions of Al-13 and Al-30 with respect to H+ concentration are composed of two parallel first-order and second-order reactions, and the reaction orders are 1.169 and 1.005, respectively. The acid decomposition rates of Al-13 and Al-30 increase slightly when the temperature increases from 20 to ca. 35 A degrees C, but decrease when the temperature increases further. Al-30 is more stable than Al-13 in acidic solution, and the stability difference increases as the pH decreases. Al-30 is more possible to become the dominant species in polyaluminum coagulants than Al-13. The acid catalyzed decomposition and followed by recrystallization to form bayerite is one of the main processes that are responsible for the decrease of Al-13 and Al-30 in polyaluminum coagulants during storage. The deprotonation and polymerization of Al-13 and Al-30 depend on solution pH. The hydrolysis products are positively charged, and consist mainly of repeated Al-13 and Al-30 units rather than amorphous Al(OH)(3) precipitates. Al-30 is less stable than Al-13 upon alkaline hydrolysis. Al-13 is stable at pH < 5.9, while Al-30 lose one proton at the pH 4.6-5.75. Al-13 and Al-30 lose respective 5 and 10 protons and form [Al-13] (n) and [Al-30] (n) clusters within the pH region of 5.9-6.25 and 5.75-6.65, respectively. This indicates that Al-30 is easier to aggregate than Al-13 at the acidic side, but [Al-13] (n) is much easier to convert to Alsol-gel than [Al-30] (n) . Al-30 possesses better characteristics than Al-13 when used as coagulant because the hydrolysis products of Al-30 possess higher charges than that of Al-13, and [Al-30] (n) clusters exist within a wider pH range.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Al-Li合金是近年发展起来的新型航空材料,具有低密度、高强度的特点。目前世界上正就如何进一步提高其断裂韧性,使Al-Li合金尽早走出实验室,获得实际用进行广泛,深入的研究。熔盐电解法就是在这种情况下发展起来的。虽然此法现在尚处于研究的初级阶段,但已以其能够在较简单的设备上制备低Na高纯Al-Li合金的特点受到广泛的重视,是一种很有前途的发展方向。针对我国的技术、设备现状,在参考国外研究结果的基础上,采用熔盐电解法制备Al-Li母合金 → 应用合金的制备方法是可以尽快赶上世界发步伐的有效途径。因此,本文作为整个熔盐电解制备Al-Li合金系统研究的一部分,针对目前在此领域中很多应用基础问题,诸如:作为新的电解体系正在探索中的LiCl-KCl-LiF三元相图,Li在液体Al阴极中的扩散系数,利用熔盐电解法制备低Na高纯Al-Li合金的热力学基础及如何克服LiCl强烈的吸水性给电解工艺带来的种种不便等均未得到系统研究的现状,设计完成了一系列有关熔盐电化学和热力学实验,填补了本领域的一些研究空白,并为进一步系统研究工艺条件提供了重要的参考数据。1.用NH_4Cl氯化Li_2CO_3的研究 根据热力学从理论上论证了在200 ℃左右下述氯化反应:Li_2CO_3 + 2NN_4Cl = 2LiCl + 2NH_3~↑ + H_2O~↑ + CO_2~↑可以进行完全。利用DSC方法测定反应产物LiCl的纯度,并用离子色谱法分析反应产物中CO_3~=的含量,结果均证明:在Li_2CO_3:NH_4Cl = 1:4 (mol)时,Li_2CO_3可以定量转化为LiCl,剩余的NH_4Cl完全分解。根据热重分析结果推测NH_4Cl氯化Li_2CO_3的反应历程为:Li_2CO_3 + 2NH_4Cl = 2LiCl + 2NH_3~↑ + H_2O~↑ + CO_2~↑ NH_4Cl = HCl~↑ + NH_3~↑ 而并非是想像中的:NH_4Cl = HCl~↑ + NH_3~↑ 2HCl + Li_2CO_3 = 2LiCl + H2O~↑ + CO_2~↑利用X-射线衍射方法分析产物,结果亦说明氯化可以成功。将1:4(mol)= Li_2CO_3:NH_4Cl混合样品在差热分析反应炉中直接加热测定反应产物LiCl的溶点,并与纯LiCl样品熔点的测定结果相比较,二者完全一致。以上结果说明:不仅可用此氯化反应产物代替LiCl应用于熔盐电解制备Al-Li合金中,而且还可将其应用于LiCl体系的相图测定中。因Li_2CO_3,NH_4Cl均不吸水,极易处理,因此以上研究结果无论对于Al-Li合金的工艺研究还是其他有关LiCl体系的基础研究都是很有价值的。2.直接氯化法制备LiCl-KCl-LiF三元相图的研究。LiCl-KCl-LiF三元相图是研究此体系电解机制的重要基础。为将以上直接氯化法应用于差热分析中制作此三元体系相图,首先用直接氯化法测定了三个已知二元LiCl体系相图:LiCl-KCl;LiCl-LiF;LiCl-NaCl。与文献结果吻合很好。说明将此法应用于差热分析中制作LiCl体系相图结果是可靠的。在LiCl-KCl-LiF三元相图的测定中共做出七个垂直截面,在各截面上读出等温条件下的相界点投影到浓度三角形中,得到等温投影图。结果说明LiCl-KCl-LiF是固态完全不互溶的三元共晶体系,共有三个液-固两相区;三个液-固-固三相区;一个液-固-固-固四相区,(三元共晶平面)和一个固-固-固三相区。四相点温度为348 ℃,其组成在三相平衡线的交点处,在实验上测出近似等于:41.4KCl + 57.3LiCl + 1.3LiF (mol)。3.氯化物体系中Li~+, Na~+析出电位的比较及其去极化作用的研究。在正常电化序中,Li~+应先于Na~+析出。但在以Al作阴极电解LiCl体系时,则由于Li~+在Al上有较强的去极化作用而提前析出。这是熔盐电解法可以制备低Na,高纯Al-Li合金的基础。本文在理论上对此问题进行了较深入的研究。具体内容包括(1)。测定Li~+, Na~+在二元氯化物体系中的析出电位。通过在Al阴极,Mo阴极上二离子析出电位的比较,确认了Li~+在Al阴极上产生很强的去极化作用是能利用电解法制备低Na高纯Al-Li合金的根本原因。并为在工艺研究中选择合适的电流密度提供了参考依据。(2).根据热力学理论推导出合金化反应产生的自由焓变化与去极化作用的关系:ΔG_x + ΔG_m = -nFΔE。揭示了产生去极化作用的原因。并根据ΔG_x(偏摩尔过剩自由焓)与合金结构的关系提出可以利用二元合金相图推测极化类型及极化大小。并根据动力学原理对温度对极化的影响提出了自己的看法。(3).求出合金化反应的热效应,认为在一定条件下亦可利用此值作为判断去极化作用大小的标准。(4).测定Li~+, Na~+在Al-Cu, -Al-RE合金上的析出电位。结果表明Cu,RE的存在均可加强Li~+在阴极上的去极化作用,进一步加大了Li~+, Na~+析出电位之间的差别,有利于制备更纯的Al-Li 使金。为直接生产Al-Cu-Li, Al-RE-Li三元母合金奠定了基础。(5)测定Li~+在不同组成配比的LiCl-KCl熔体中,在Al阴极上的析出电位,并求出LiCl的离子平均活度系数γ=0.71 (T = 740 ℃), 熔体对理想状态产生负偏离。4.利用阳极计时电位法测定T=720 ℃时Li在液体Al中的扩散系数D_(Li/Al) = 4.94 * 10~(-5)cm~2·s~(-1),与利用Stocks-Einstan公式计算出的理论值D_(Li/Al) = 4.85 * 10~(-5)cm~2·s~(-1)吻合较好。5.在上述理论研究的基础之上进行了工艺初探,所得初步结论有:(1).加入LiF可以提高电效。(2).采用电流密度为1 A/cm~2时,不加搅拌亦可制备出成份均匀,含Li量为10%(w.f)的Al-Li合金。(3).根据实验结果提出 Li在熔体中的熔解可能是影响电流效果的主要原因。

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In order to realize the common-emitter characteristics of the tris(8-hydroxyquinoline) aluminium (Alq(3))-based organic transistors, we used Au/Al double metal layer as the base, thus the vertical metal-base transistors with structure of Al/n-Si/Au/Al/Alq(3)/LiF/Al were constructed. It was found that the contact properties between the base and the organic semiconductors play an important role in the device performance. The utilization of Au/Al double layer metal base allows the devices to operate at high gain in the common-emitter and common-base mode at low operational voltage.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report the fabrication of permeable metal-base transistors based on bis(2-methyl-8-quinolinolato-N1,O8)-(1,1'-biphenyl-4-olato) aluminum (BAlq(3))/tri(8-hydroxyquinoline) aluminum (Alq(3)) isotype heterostructure as emitter layer. In this transistor, n-Si was used as the collector, LiF/Al as the emitter electrode, and Au/Al bilayer metal as the base. We show that the leakage current is greatly reduced in Al/n-Si/Au/Al/BAlq(3)/Alq(3)/LiF/Al devices with respect to Al/n-Si/Au/Al/Alq(3)/LiF/Al devices due to the utilization of BAlq(3)/Alq(3) isotype heterostructure emitter, leading to high common-base and common-emitter current gains at low driving voltages.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The oxovanadium phosphonates (VO(P-204)(2) and VO(P-507)(2)) activated by various alkylaluminums (AlR3, R = Et, i-Bu, n-Oct; HAIR(2), R = Et, i-Bu) were examined in butadiene (Bd) polymerization. Both VO(P-204)(2) and VO(P-507)(2) showed higher activity than those of classical vanadium-based catalysts (e.g. VOCl3, V(acac)(3)). Among the examined catalysts, the VO(P-204)(2)/Al(Oct)(3) system (I) revealed the highest catalytic activity, giving the poly(Bd) bearing M-n of 3.76 x 10(4) g/mol, and M-w/M-n ratio of 2.9, when the [Al]/[V] molar ratio was 4.0 at 40 degrees C. The polymerization rate for I is of the first order with respect to the concentration of monomer. High thermal stability of I was found, since a fairly good catalytic activity was achieved even at 70 degrees C (polymer yield > 33%); the M-n value and M-w/M-n, ratio were independent of polymerization temperature in the range of 40-70 degrees C. By IR and DSC, the poly(Bd)s obtained had high 1,2-unit content (> 65%) with atactic configuration. The 1,2-unit content of the polymers obtained by I was nearly unchanged, regardless of variation of reaction conditions, i.e. [Al]/[V], ageing time, and reaction temperature, indicating the high stability of stereospecificity of the active sites.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, a method was established for the determination of impurities in high purity tellurium by inductively coupled plasma mass spectrometry (ICP-MS) after Fe(OH)(3) coprecipitation. After comparison of coprecipitation ability and separation efficiency between Fe(OH), and Al(OH)(3), Fe(OH)(3) was chosen as the precipitate. A separation factor of 160 for 200 mg tellurium was obtained under conditions of pH 9 and 2 mg of Fe3(+). The 13 elements, such as Bi, Sn, Pb, In, Tl, Cd, Cu, Co, Ni, Zn, Ti, Be and Zr, could be almost completely coprecipitated under these conditions. In addition, Te memory effect imposed on the ICP-MS instrument was assessed, as well as Te matrix effect that caused the low recovery of Ga, As, Sb and V in real sample was discussed. Finally, the method was evaluated through recovery test and was applied to practical sample analysis, with detection limits of most of the elements being below 0.15 mug g(-1) and R.S.D. below or at approximately 10%, which indicated that this method could fully satisfy the requirements for analysis of 99.999% similar to 99.9999% high purity Te.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

[Al(C15H9O3)(3)](2) . 2CHCl(3) . 8H(2)O was synthesized, and its crystal structure was determined. It belongs to trigonal system, R3, a=b=1. 655 8(3) nm, c=3. 646 5(20) nm, alpha = beta = 90 degrees, gamma = 120 degrees, V = 8. 656 08(0. 005 86) nm(3). D-c = 1.45 g/cm(3), mu(Mo K alpha) = 3. 20 cm(-1), F (000) = 3 924. The crystal structure was solved by Patterson and Fourier techniques, and refined by a block-diagonal least-squares method. A total of 3 737 independent intensity data were collected, of which 1 033 with I greater than or equal to 3 sigma(I-0) were observed, R = 0. 091 8, Rw=0. 091 8. Al3+ ion was 6-coordinated, bound to six oxygen atoms from three 3-hydroxyflavones to form a distortional coordination octahedron.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

本研究利用线性扫描伏安法和恒电位电解法,对Al-Nd合金在氯化物溶体中的阳极溶解行为进行了研究。结果表明,Al-Nd的阳极溶解以钕原子由合金内部向合金表面的扩散为控制步骤。合金阳极溶解的价态为3。计算溶解的电流效率超过100%。

Relevância:

90.00% 90.00%

Publicador:

Resumo:

利用全谱直读等离子体发射光谱法(ICP—AES)测定了3种秦艽组植物10种微量元素(Cu,Zn,Fe,Mn,Ni,Co,Sn,V,Al,Ti)的含量,并进行了比较分析。结果表明,所测定元素在3个不同物种内的含量排列顺序基本一致,显示了三者在元素富集方面的相似性。就同一种元素在3个物种内的富集水平而言,以麻花艽根部具有较高含量的元素Cu,Zn,Co,Al和Ti,管花秦艽根部则大量富集了其余5种微量元素,达乌里秦艽对元素的吸收积累能力居中,揭示了不同物种对同一元素富集能力的差异。该研究可为秦艽类植物资源的深入开发利用提供参考。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

该文以提高在高温、高压、高速、重载和腐蚀介质等恶劣工况下使用的枪管、炮管、发动机叶片、热轧辊等零部件使用性能和寿命为应用背景,在综述前人工作的起点上,以制备科学的研究为基础,从熔覆层的使用性能和工艺性能(降低残余应力,防止开裂)出发,利用激光熔覆和复合材料原位合成技术,围绕成分、相组成、组织结构控制和工艺优化,设计并研制了FeMoSi、MoSi<,2>-SiC、α-Fe(Al)/Fe<,3>Al和FeAl四种在不同温度和服径工况下使用,能耐高温氧化、烧蚀和磨损的优异的新型高温结构用金属间化合物涂层.用OM、XRD、SEM、EDAX和显微硬度仪对熔覆层的组织结构/性能进行了研究.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

制备了不同Al(PO33含量的掺铥系列氟磷玻璃,研究了其结构、热稳定性和光谱性质。随着Al(PO33含量的增加,该系列玻璃的密度降低,折射率增加,差热分析表明,转变温度、析晶起始温度、析晶峰温度和熔化温度增加。Al(PO33摩尔浓度在7%~9%时析晶稳定性最佳。采用归一化的拉曼光谱分析了材料的结构和声子状况,对于该系列氟磷玻璃,Al(PO33含量的增加不会影响声子能量,但使声子密度增大。测试了样品的吸收光谱,Tm^3+的^3H6→^3F4在第三通信窗口的L波段有明显吸收。与在其它玻璃基质中相比,T

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fluorophosphate glasses with various content of Al(PO3)(3) were prepared. With the increment of Al(PO3)(3) content, density decreases while refractive index increases, and transition temperature, crystallization peak temperature and melt temperature increase which were suggested by differential scanning calorimetry. These glasses exhibit the best stability against crystallization with 7-9 mol'Yo Al(PO3)(3) content. Normalized Raman spectra were used to analyze structure and phonon state. The increment of Al(PO3)(3) content does not affect phonon energy but results in the augment of phonon density. Absorption spectra were measured. H-3(6) -> F-3(4) transition exhibits absorption at L band of the third communication window. Compared with the energy of Tm3+ excited states in other glass system, F-3(4) energy of Tm3+ in these glasses is considerable higher and H-3(4) energy is considerable lower, and it can be predicted that emission band of H-3(4) -> F-3(4) transition is close to the amplified band of gain-shift Tm3+ doped fiber amplifier. Analyses of Judd-Ofelt theory suggest when Al(PO3)(3) content is no more than 7 mol%, Judd-Ofelt parameters Omega(t) and the lifetime of H-3(4) energy level of TM3+ vary little with the increment of Al(PO3)(3) content, and when Al(PO3)(3) content is more than 7 mol%, Omega(2) and Omega(6) increase and radiative lifetime of H-3(4) energy level of Tm3+ drops sharply with the increment of Al(PO3)(3) content. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Al(NO33和Y(NO33为原料,采用共沉淀法制备出粒度大小为60-100nm,颗粒呈球形的纯相YAG纳米粉。研究了前驱物在不同条件下热处理对YAG纳米粉体性能的影响,并对前驱物在焙烧过程中的物相变化进行了观察。发现延长前驱物在低温下的干燥时间会导致晶粒尺寸增大,而采用在晶化温度前后分别进行保温的方法可在较低的温度获得纯相的YAG粉体。对比了焙烧温度和保温时间对产物粒度的影响,结果表明:在保证粉体晶化完全的前提下,升高焙烧温度比延长保温时间对晶粒尺寸有更显著的影响。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A comprehensive study on the thermal stability and spectroscopic properties of Er3+/Yb3+-codoped Al(PO3)(3)-based fluorophosphate glasses is reported of the 1.5μ m fibre amplifiers in this paper. From optical absorption spectra, the Judd-Ofelt parameters of Er3+ in the glasses and several important optical properties, such as the radiative transition probability, the branching ratio and the spontaneous emission probability, have been calculated by using Judd-Ofelt theory. The fluorophosphate glass exhibits broadband near-infrared emission at 1.53μ m with a full width at half-maximum over 63nm, and a large calculated stimulated-emission cross-section of 6.85 x 10(-21)cm(2).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The thermal stability and structure of RF-RF2-AIF(3)-Al(PO3)(3) fluorophosphate glasses were investigated. Analyses of infrared absorbance spectra and Raman spectra reveal that with increasing number of alkali and alkaline earth fluoride components, the sum of P-O-P bond and O-P-O bond increases and glass network is strengthened. Consequently, the inhibition to nucleation and crystallization processes is improved, which is proved by the increment of thermal stability factors AT and S determined by differential scanning calorimetry. In addition, it was found that LiF has poor ability to form glass in univalent alkali fluorides and MgF2 has comparative strong ability to form glass in bivalent alkaline earth fluorides. (c) 2006 Published by Elsevier B.V.