324 resultados para STARK SPECTROSCOPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mossbauer spectroscopy has been used to investigate the thermal decomposition of the bioinorganic complex of europium and L-glutamine. The Mossbauer parameters can demonstrate that the water molecules in the complex and the chlorine anion in the hydrogen chloride molecule, dissociated from the complex below 200-degrees-C, are not linked directly to the europium atom. The thermal decomposition process of the complex is discussed and a possible coordination model for the europium L-glutamine complex is also proposed on the basis of the thermogravimetric and derivative thermogravimetric curves, and from some evidence obtained from the Mossbauer effects of some decomposition products of the complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this pare earth-HEDTA-serine (Ser) ternary system has been studied by potentiometric titration at 25 degrees C with an ionic strength of 0.15 mol.L-1 (NaCl). The excitation and fluorescence spectra of TbCl3, Tb-Ser, Tb-HEDTA and Tb-HEDTA-Ser have hem determined at room temperature. The stability constants of these ternary complexes have been obtained, It lieu been found that Tb-HEDTA-Ser ternary system exhibit characteriatic fluorescence spectrum of Tb3+ sensitized by two ligands,The results mean that the chemical hood between the control ion and the ligand in this ternary system is predominantly ionic in character,and the energy transfer from ligand to Tb8+ is performed by a kind of abort-range electron exchange action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical impedance spectroscopy (EIS) at different potentials has been used to study the oxygen reduction reaction (ORR) in 3.5% NaCl solution on glassy carbon (GC) electrode in this work. Results show that ORR consists of three two-electron reaction steps and both superoxide ion (O-2(-)) and hydrogen peroxide (H2O2), which are produced by ORR, obstruct the diffusion of oxygen to the surface of the electrode and make the EIS results change into a transmissive finite diffusion process with the real part contraction and a reflective finite diffusion process from a semi-infinite diffusion process. The values of electron transfer resistance (R-t) and diffusion resistance (R-d) were calculated from EIS. O-2(-) influenced strongly on the Rt values and induced a maximum at -0.45 V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.