271 resultados para Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The stability of diester-diterpenoid alkaloids (DDA) from plants of the genus Aconitum L. has been studied in different solvents and pH buffers. The HPLC/ESIMS method for analysing the concentration of DDA was established and DDA's decomposition products were elucidated by HPLC/ESI-MS/MSn. In different solvents, e.g. dichloromethane, ether, methanol and distilled water, the decomposition pathways of DDA are quite different and their difference in stabilities depends on the difference of their structures, in which substituents at the N atom and substituents at C-3 are different. The pyrolytic products of DDA, such as deacetoxy aconitine-type alkaloids, have been observed in the above solvents, whereas 8-methoxy-14-benzoyl aconitine-type alkaloids have been obtained only in methanol.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two Meinhard microconcentric nebulizers, model AR30-07-FM02 and AR 30-07-FM005, were employed as a self-installed micro-sampling system for inductively coupled plasma-mass spectrometry (ICP-MS). The FM02 nebulizer at 22 muL/min of solution uptake rate gave the relative standard deviations of 7.6%, 3.0%, 2.7%, 1.8% for determinations (n = 10) of 20 mug/L Be, Co, In and Bi, respectively, and the detection limits (3s) of 0.14, 0.10, 0.02 and 0.01 mug/L for Be, Co In and Bi, respectively. The mass intensity of In-115 obtained by this micro-sampling system was 60% of that by conventional pneumatic nebulizer system at 1.3 mL/min. The analytical results for La, Ce, Pr and Nd in 20 muL Wistar rat amniotic fluid obtained by the present micro-sampling system were precisely in good agreement with those obtained using conventional pneumatic nebulization system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method for the determination of Au, Pt and Pd in geological samples is described. Au, Pt and Pd can be separated and concentrated quantitatively by C-410 anion-exchange resin in the condition of 1.5 mol/L HCl with the adsorption rates of 91.2%, 100.0% and 95.7% respectively. No interference exists from coexisting elements except for Ge(IV), Cr(VI),Ti(IV) in inductively coupled plasma-mass spectrometry. The detection limits are 0.27 mug/L, 0.40 mug/L and 0.19 mug/L for Au, Pt and Pd respectively. The results of these elements in standard geological materials are in agreement with certified values with precision of 19.2% RSD for Au (n = 8), 28.1% RSD for Pt (n=8), and 15.6% RSD for Pd (n=8).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Using Nd: YAG laser (532 nm) pumped mixed-dye laser. we obtained the output of this dye enhanced at the wavelength interval equivalent to that given by the copper vapor laser pumped dye laser. This measure favored is with the measurement of single-color three-photon resonant ionization spectrum of atomic uranium in the range of 562-586 nm,which is otherwise not efficiently covered by Nd: YAG laser pumped dye laser with any single dye. Thus 140 U I energy levels were obtained and the peaks of interest 575.814 nm and 575.836 rim were well resolved and their relative intensity determined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Three known flavonoids, quercetin, quercitrin (quercetin-3-0-rhamnoside) and rutin (quercetin-3-0-rutinoside), have been identified for the first time in the leaves of Acanthopanax senticosus Harms by using electrospray tandem mass spectrometry techniques (ESI-MSn). The flavonoid hyperin (quercetin-3-0-beta-galactoside), already known to be present, was also investigated. The diagnostic fragment ions of the aglycone quercetin were obtained in the ESI-MSn experiments, and a fragmentation mechanism proposed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The essential oil in purple magnolia leaves was extracted by steam distillation approaches. The oil obtained was dried with anhydrous magnesium sulfate. According to the analysis of gas chromatography/mass spectrometry, more than 40 peaks were separated and 32 compounds were identified. The identified constituents represent 95% of the peak area of the essential oil. The main compounds were germacrene-D, santolina triene, caryophyllene, 1,3,7-octatriene, 3,7-dimethyl, and camphene, etc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The multicolour three-photon resonant ionization spectra of U-238 were measured by using the pulsed dye lasers system synchronously pumped by a frequency doubled Nd:YAG-laser 532 nm output(operated at 10 Hz),a device for atomic beam of U, time-of-flight mass spectrometer and boxcar integrator. The dye laser pulses have a 6 ns duration. Beams from the dye lasers, which have the same polarization direction and are focused by lenses, entered an interaction chamber through opposite windows on a common axis and spatialy overlapped the U atomic beam. The optical pulse from dye laser DL2 was delayed to arrive at the interaction region 8 ns after the pulse from dye laser DL1; in the same way,the pulse from DL3 was delayed 8 ns after from DL2. The atomic beam device was made from stainless steel. We generated the U vapor by heating solid U in a graphite crucible by e-type electron -field on first excited states were studied in uranium atom. The question how to determine single-colour, two-colour and three-colour three-photon resonant ionization peak in the three-colour three-photon resonant ionization spectra diagram were solved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent important applications of inductively coupled plasma mass spectrometry in biological samples analysis are reviewed. The sample preparation, sample introduction techniques, interference correction and typical applications are introduced in detail with 154 references.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method for the determination of impurity elements in high purity cadmium by inductively coupled plasma mass spectrometry was developed. The spectral interference arising from Cd was discussed and the magnitude of interference by the polyatomic ion of Cd was compared. The effect of the high concentration Cd on the analyte signal was studied. The results showed that Cd possessed both significant suppression effects on the light mass elements signal and enhancement effects on the heavy mass elements signal,and the effects can be corrected by the use of internal standard elements. In this paper, Y and Bi was employed for the light mass elements and the heavy mass elements,respectively. As, Be, Co, Cu, Ga, Ge, Mn, Mo, Pb, Ni, Sr, Au, Tl, Th, V and U in high purity cadmium were determined. Detection limits are 0.005-0.052 mu g L-1,and the recoveries of standard addition are 82%-108%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Resonance electron capture mass spectrometry, in which an additional information coordinate, the energy of electron capture, is applied, has a high sensitivity and a high specificity. It is extensively used to study the structure elucidation, the mechanism of ion formation and the detection, identification and quantification of organic substances in mixture.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Three triterpenoid saponins in crude extracts from Acanthopanax senticosus Harms have been investigated by use of multi-stage mass spectrometry (MSn) combined with electrospray ionization (ESI), MSn spectra were applied to direct structure elucidation of these saponins in crude plant extracts, in positive and negative ion mode. The characteristic fragmentations of triterpenoid saponins are discussed. The method provides a means of rapid initial screening of crude plant extracts. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method for the quantatitive determination of pethidine in human urine by liquid secondary ion and tandem mass spectrometry is presented. Quantification was carried out by using ketamine as internal standard. It was found that the collision-induced dissociation (CID) spectrum of the [M + H](+) ion of pethidine exhibited a prominent daughter ion at mit 220 and ketamine also yielded the same daughter ion at nit 220, For ((quadrupole)) quantitative analysis, the first quadrupole mass filter was set to transmit mit 220 and a narrow-range magnet scan yielded a spectrum of parents, including mit 238 and 248, corresponding to ketamine and pethidine, respectively. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Studies of low-energy collision-induced dissociation and isotopic labeling on ionized tetrahydroimidazole-substituted methylene P-diketones by tandem mass spectrometry showed that their unimolecular fragmentations may involve the reactions of intermediate ion/neutral complexes and multistep rearrangements. The corresponding mechanisms were proved by semiemipirical calculations of PM3 and AM1 methods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Gas-phase ion-molecule reactions of buckminsterfullerene (C-60) with the ion systems generated from the self-chemical ionization of alkyl methyl ethers (CH3OR, R = n-C2H5, n-C3H7, n-C4H9) were studied in the ion source of a mass spectrometer. The adduct cation [C60C2H5O](+) and protonated molecule [C60H](+) were observed as the major products. The former adduct ion was produced by the reactions of C-60 with the methoxymethyl ion [CH3OCH2](+), and the latter resulted from the proton transfer reactions from protonated alkyl methyl ethers to C-60 It is suggested that the [3+2] cycloadduct to a 6-6 bond of C-60 (a C-C bond common to two annulated six-membered rings) is the most favorable structure among the probable isomers of [C60C2H5O](+). (C) 1998 John Wiley & Sons, Ltd.