417 resultados para Da xue.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Differential cross sections for the quasi-elastic scattering of C-16 at 47.5 MeV/nucleon from C-12 target are measured. Coupled-channels calculations are carried out and the optical potential parameters are obtained by fitting the experimental angular distribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在北京13 MV串列加速器上利用20—50MeV O5+离子研究Au的L壳层X射线产生截面. 实验结果表明σ(Ll)/σ(Lα) ,σ(Lβ)/σ(Lα) 和σ(Lγ)/σ(Lα)与ECPSSR理论计算结果符合比较好.在实验中由于较高的能量,在能量点存在能移现象.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u, Ar-36 delivered by CSRm were injected into CSRe. The revolution periods of the stored ions, which depend on the mass-to-charge ratios of the stored ions, were measured with a time-of-flight detector system. The results show that the mass resolution around 8 x 10(-6) for Delta m/m is achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four high-purity germanium 4-fold segmented Clover detectors have been applied in the experiment of neutron-rich nucleus N-21. The performance of those, four Clovers have been tested with radioactive sources and in-beam experiments and the main results including energy resolution, peak-to-total ratios, the variation of the hit pattern distribution in difficult crystals of one Clover detector with the energy of gamma ray, and absolute full energy peak detection efficiency curve, were presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The LPT (Lanzhou Penning Trap) is under construction and its task is to perforin direct mass measurement of fusion-evaporation residue, and if possible for heavy isotopes. Detailed simulations have been clone for a good understanding to the ion's movement and mechanics in the trap. The optimizal ion of the LPT is also performed based on the simulation. With a scale of 0.5 mm per grid used in the, simulation and many other limitations a highest mass resolution has been achieved to be 1.9 x 10(-5). An unexpected behavioin in the simulation related to magnetron motion has been found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method of loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). The amplification could be finished in 60 min under isothermal condition at 64 degrees C by employing a set of four primers targeting the cap gene of PCV2. The LAMP assay showed higher sensitivity than the conventional PCR, with a detection limit of five copies per tube of purified PCV2 genomic DNA. No cross-reactivity was observed from the samples of other related viruses including porcine circovirus type 1 (PCV1), porcine parvovirus (PPV), porcine pseudorabies virus (PRV) and porcine reproductive and respiratory syndrome virus (PRRSV). The detection rate of PCV2 LAMP for 86 clinical samples was 96.5% and appeared greater than that of the PCR method. The LAMP assay reported can provide a rapid yet simple test of PCV2 suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction. (c) 2008 Elsevier B.V. All rights reserved.