222 resultados para aluminium compounds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel strategy for the screening and analysis of biologically active compounds in traditional Chinese medicine by molecular biochromatography is proposed. Molecular biochromatography with human serum albumin (HSA) immobilized on silica as stationary phase was used to screen and analyse the bioactive compounds in the typical Chinese medicine of Angelica sinensis (Oliv.) Diels. Ten peaks showed retention on this column, which is based on their affinity for HSA. Ferulic acid and liguistilide were identified as the principal active components, which agrees very well with the results in the literature. A quality control method was also developed based on the simultaneous determination the concentrations of ferulic acid and liguistilide in solutions of Angelica sinensis (Oliv.) Diels extracted with water and methanol. It was observed that the concentrations of ferulic acid and liguistilide in solution extracted with methanol were 2 and 53 times higher, respectively, than those with water. It was shown that molecular biochromatography is an effective way of analysing and screening biologically active compounds in traditional Chinese medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The migration mechanism of ionizable compounds in capillary electrochromatography (CEC) is more complicated than in high performance liquid chromatography (HPLC) due to the involvement of electrophoresis and the second chemical equilibrium. The separation mechanism of ionizable compounds in CEC has been studied theoretically. The electrochromatographic capacity factors of ions (k *) in CEC and in the pressurized CEC are derived by phenomenological approach. The influence of pH, voltage, pressure on k* is discussed. in addition, the k * of weak acid and weak base are derived based on acid-base equilibrium and the influence of pH on k * is studied theoretically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With using short capillary column packed with porous and non-porous ODS stationary phases, high speed separation of 6 neutral aromatic compounds within 36 s by capillary electrochromatography (CEC) has been performed. Good reproducibility of the migration times for those solutes in high speed CEC was observed with RSD less than 1%. Both the linear velocity of EOF and the current linearly increases with the applied voltage, which means that the thermal effect by Joule heating was small. However, the capacity factor of solutes was found to decrease with the increase of the applied voltage, which was caused by the fact that about several seconds needed for the increase of voltage from 0 to applied value on a commercial CE instrument made larger contributions to the migration times of the early eluted compounds than those of lately eluted ones during high speed CEC, and voltage effect would increase with the higher applied voltage used. The linear relationship between the logarithm of capacity factor and the number of carbon for homologous compounds was observed, and positive value of slope means that the hydrophobicity of solutes is one of the main contribution factors to retention in high speed CEC packed with ODS stationary phases.