186 resultados para TOOTH EXTRACTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary 8-hydroxydeoxyguanosine (80HdG) has been considered as an excellent marker of individuals at high risk of developing cancer. Until now, urinary 80HdG has largely been measured by high-performance liquid chromatography with electrochemical detection. A new method for the analysis of urinary 80HdG by high-performance capillary electrophoresis has been developed and optimized in our laboratory. A single step solid-phase extraction procedure was optimized and used for extracting 80HdG from human urine. Separations were performed in an uncoated silica capillary (50 cm x 50 tm i.d.) using a P/ACE MDQ system with UV detection. The separation of 80HdG from interfering urinary matrix components is optimized with regard to pH, applied voltage, pressure injection time and concentration of SDS in running buffer. The detection limit of this method is 0.4 mug/ml, the linear range is 0.8-500 mug/ml, the correlation coefficients levels is better than 0.999. The developed method is simple, fast and good reproducibility, furthermore, it requires a very small injection volumes and low costs of analysis, which makes it possible to provide a new noninvasive assay for an indirect measurement of oxidative DNA damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 muL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized. (C) 2004 American Society for Mass Spectrometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organophosphorus pesticides (OPPs) in vegetables were determined by stir bar sorptive extraction (SBSE) and capillary gas chromatography with thermionic specific detection (TSD). Hydroxy-terminated polydimethylsioxane (PDMS) prepared by sol-gel method was used as extraction phase. The effects of extraction temperature, salting out, extraction time on extraction efficiency were studied. The detection limits of OPPs in water were <= 1.2 ng/l. This method was also applied to the analysis of OPPs in vegetable samples and matrix effect was studied. Linear ranges of OPPs in vegetable samples were 0.05-50 ng/g with detection limits <= 0. 15 ng/g and the repeatability of the method was less than 20% relative standard deviation. (c) 2005 Elsevier B.V. All rights reserved.