225 resultados para STRONTIUM COMPOUNDS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid capillary electrophoresis method for the separation of five natural pharmacologically active compounds from extracted Rhodiola, namely salidroside, tyrosol, rhodionin, gallic acid and ethyl gallate has been developed. The separation of five natural pharmacologically active compounds was carried out in a fused-silica capillary with 14 mM boric acid, 30 mM SDS and 2.5% acetonitrile, adjusted to pH 10.7 with NaOH. Applied potential was 21 kV. The temperature of the capillary was maintained at 25 degreesC by the instrument thermostating system, with the correlation coefficients of 0.9805-0.9989 for migration time, and relative standards of < 3.52% for peak areas. The established method is rapid and reproducible for the separation of five natural pharmacologically compounds from extracts of Rhodiola with satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pharmacologically active xanthone compounds isolated from Swertia przewalskii pissjauk were well separated by capillary electrophoresis (CE) within 5 min, using a running buffer of 25 mM disodium tetraborate at pH 9.0. Quantitative determination was shown to be possible because regression equations revealed a linear relationship between the peak area of each constituent and its concentration, with correlation coefficients of 0.9972-0.9994. The relative standard deviations were between 0.44%-0.73% for migration times and 2.52%-4.28% for peak areas. The dissociation constant of 1,7-O-beta-D-glucopyranosyl-8-hydroxy-3,7-dimethoxyxanthone, 1,8-dihydroxy-3, 7-dimethoxy-xanthone and 1,7-dihydroxy-3,8-dimethoxyxanthone were also measured by the CE method, giving a value of 9.04, 8.94, and 8.59, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel bonded phase for reversed-phase HPLC was synthesized in two steps. Octylamine was first reacted with beta-(3,4-epoxycyclohexyl)ethyltrimethoxysilane (beta -ECTS) and then the intermediate product was coupled onto porous silica. The prepared packing was characterized by elemental analysis, solid-state C-13 NMR and Fourier transform infrared (FT-IR). Chromatographic evaluations were carried out by using a mixture of organic compounds including acidic, basic and neutral analytes and methanol-water as binary mobile phase. The results showed that the stationary phase has excellent chromatographic properties and is resistant to hydrolysis between pH = 2 similar to 8. It can be used efficiently for the separation of basic compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The micro-pore configurations on the matrix surface were studied by SEM. The matrix of molten carbonate fuel cell (MCFC) performance was also improved by the better coordination between the reasonable radius of the micro-pores and the higher porosity of the cell matrix. The many and complicated micro-pore configurations in the cell matrix promoted the volatilization of the organic additives and the burn of polyvinyl butyral (PVB). The smooth volatilization of the organic additives and the complete burn of PVB were the significant factors for the improved MCFC performance. Oxygen diffusion controlled-burn mechanism of PVB in the cell matrix was proposed. (C) 2002 Published by Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Separation of the acidic compounds in the ion-exchange capillary electrochromatograph (IE-CEC) with strong anion-exchange packing as the stationary phase was studied. It was observed that the electroosmotic flow (EOF) in strong anion-exchange CEC moderately changed with increase of the eluent ionic strength and decrease of the eluent pH, but the acetonitrile concentration in the eluent had almost no effect on the EOF. The EOF in Strong anion-exchange CEC with eluent of low pH value was much larger than that in RP-CEC with Spherisorb-ODS as the stationary phase. The retention of acidic compounds on the strong anion-exchange packing was relatively weak due to only partial ionization of them, and both chromatographic and electrophoretic processes contributed to separation. It was observed that the retention values of acidic compounds decreased with the increase of phosphate buffer and acetonitrile concentration in the eluent as well as the decrease of the applied voltage, and even the acidic compounds could elute before the void time. These factors also made an important contribution to the separation selectivity for tested acidic compounds, which could be separated rapidly with high column efficiency of more than 220 000 plates/m under the optimized separation conditions. (C) 2000 Elsevier Science BN. All rights reserved.