203 resultados para Phosphate sensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enzymatic degradation of poly(epsilon-caprolactone) (PCL) films in phosphate buffer solution containing lipases has been studied by DSC, WAXD and SEM. Three lipases, pseudomonas lipase (PS), porcine pancreatic lipase (PP), and candida cylindracea lipase (AY), were used. The results showed that the degradation of PCL films in phosphate buffer solution containing PP or AY was very slow: no weight loss could be found within 1 week. However, PCL film could degrade rapidly and completely within 4 days in phosphate buffer solution containing PS lipase. (C) 1997 Elsevier Science Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ytterbium(III) and praseodymium(III) complexes of 2-carboxyethylgermanium sesquioxide (Ge-132) can hydrolyze the phosphodiester linkage of 3',5'-cyclic adenosine monophosphate (cAMP) and 3',5'-cyclic deoxyadenosine monophosphate (dcAMP). Both cAMP and dcAMP are hydrolyzed with high selectivity, yielding predominantly 3'-monophosphates. The selectivity and activity for hydrolyzing cAMP and dcAMP by lanthanide metal(III) complexes and lanthanide metal ions are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cleavage of 3',5'-cAMP, 3',5'-cGMP and 3',5'-dcAMP by lanthanides has been investigated by HPLC and H-1 NMR. Rapid cleavage of cAMP, cGMP and dcAMP by Ce(III) under air at pH 8 and 37 degrees C has been observed. Regioselective cleavage of P-O(5') bond in cAMP, cGMP and dc;aMP tu give the corresponding 3'-AMP, 3'-GMP and 3'-dAMP by lanthanide chlorides has been achieved, and 3'-AMP and 3'-GMP are cleaved to adenosine(A) and guanosine(CT) more slowly, respectively, The notable difference in reactivity between Ce(III) and the other lanthanide ions under air has also been studied. The cleavage is enhanced with the increase in the molar fraction of Ce(IV). The fast cleavage of cAMP by Ce(III) under air at pH 8 is ascribed to the resultant Ce(IV) in the reaction mixture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new phosphate, KMgY(PO4)(2), isostructural with xenotime, was firstly reported in detail. It crystallizes in tetragonal system with space group I4(1)/amd (No. 141). The cell parameters were obtained from X-ray powder diffraction data with a=0.6886, c=0.6025 nm, 2=2. The proposed structure of KMgY(PO4)(2) was further confirmed by its vibrational spectra, IR and Raman spectra, which were also compared with those of iso-structural YPO4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new compound KMgLa(PO4)(2), isotypic with monoclinic LaPO4, is reported. Its cell parameters have been determined from X-ray powder diffraction data. Crystallization occurs in the monoclinic space group P2(1)/n (No. 14) with a = 6.839(3) Angstrom, b = 7.066(1) Angstrom, c = 6.523(3) Angstrom, beta = 103.42(4)degrees, and Z = 2. It was found that the KMgLa(PO4)(2) phase was isostructural with monoclinic LaPO4. The difference between them was that half of the La atoms in LaPO4 were couplingly substituted with the same amount of Mg and K atoms. This isomorphous substitution was confirmed by IR and Eu3+-doped excitation and emission spectra and by elemental analysis of single crystals. The spectroscopic data were compared with those of LaPO4:Eu3+. (C) 1995 Academic Press, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A layer of palladium particles was electrodeposited on a glassy carbon electrode. The dispersed Pd particles resulted in a large decrease in overvoltage for the electrochemical oxidation of H2O2 down to +0.4 V vs. Ag/AgCl, based on which a new kind of cholesterol sensor was fabricated. Cholesterol oxidase was immobilized on the Pd-dispersed electrode by cross-linking with glutaraldehyde and a layer of poly(o-phenylenediamine) (PPD) film was electropolymerized on the enzyme layer. The sensor shows a linear response in the concentration range 0.05-4.50 mmol l-1 with a rapid response of less than 20 s. The polymer film can prevent interference from uric acid and ascorbic acid and also increases the thermal stability of the sensor. The sensor can be used for 200 assays without an obvious decrease in activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A glassy carbon electrode (GCE) modified with palladium provides excellent electrocatalytic oxidation of hydrogen peroxide. When the electrolyte contains palladium chloride and glucose oxidase, the GCE can be modified by electrochemical codeposition at a given potential. The resulting modified surface was coated with a thin film of Nation to form a glucose sensor. Such a glucose sensor was successfully used in the flow-injection analysis of glucose with high stability and anti-poisoning ability. It gave a detection limit of 1 X 10(-7) M injected glucose, with a linear concentration range of 0.001-8 mM. There is no obvious interference from substances such as ascorbate and saccharides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new type of solid-state galvanic cell for detecting a small amount of hydrogen in air at room temperature is proposed. The sensor cell is a potentiometric cell using Ce0.95Ca0.05F2.95 as solid-state electrolyte. The cell exhibits good sensing properties to hydrogen in air at room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A glucose oxidase (GOD) electrode with ferrocene (Fc) used as an electron transfer mediator has been described. Using Nafion, Fc was modified on a glassy carbon (GC) electrode surface, and glucose oxidase was then immobilized on the Fc-Nafion film, forming a GOD-Fc-Nafion enzyme electrode. The preparation method was quite simple and rapid. The enzyme electrode showed a reversible reaction of the redox couple (Fc+/Fc), used in a biosensor system, displayed a sensitive catalytic current response (response time was less than 20 s) on variation of the glucose concentration, with a wide linear range up to 16 mM and with good repeatability. The enzyme electrode showed almost no deterioration over the course of three weeks. There was little or no interference from electro-active anions, such as ascorbic acid, to the determination of glucose based on Nafion film and lower oxidizing potentials of the enzyme electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modification of conducting polymer polypyrrole(PPy) on glassy carbon(GC)by electrcchemical technique, and the study on doping effect of Br anion and electrochemical behavior of PPy film electrode were reported.A new kind of Br~- ion selective electrode has been prepared successfully.The mechanism of the electrode potential response is based on the doping effect of anion in the conducting polymer.Effect of polymerization conditions on the potential response characteristic is investigated in dtail.The PPy...