187 resultados para Mercantile circuits


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behavior of the electroactive self-assembled monolayers (SAMs) of thiol-functionalized viologen, CH3(CH2)(9)V2+(CH2)(8)SH, where V2+ is a viologen group, on the gold electrodes is examined by cyclic voltammetry and electrochemical a.c. impedance. A monolayer of viologen is immobilized on the gold electrode surface via the Au-S bond and the normal potentials corresponding to the two successive one-electron transfer processes of the viologen active centers are -310 mV and -652 mV (vs. Ag/AgCl) in 0.1 mol l(-1) phosphate buffer solution (pH 6.96) respectively. These results suggest that the viologen SAMs are stable and well-behaved monolayers. The experimental impedance data corresponding to different forms of viologen group have been fitted to equivalent electrical circuits, and the surface capacitances and resistances have been given. The heterogenous electron transfer rates of the first and the second redox processes are 7.57 s(-1) and 1.49 s(-1) respectively through a.c. impedance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1.0 moll(-1) HCl with a pulse current density of 20 mA cm(-2), and the pulse wave parameters of t(a)/t(c) = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t(r)) to the working time (t(w)) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 moll(-1) KCl was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文在分析几种常用的基于编码器测速方法的基础上,提出了一种高性能的自适应速度测量方法。该方法选择一个可变的时间周期和编码器脉冲数来测量单位时间内的编码器脉冲数,再通过简单的计算得到转速的测量值。数字信号处理器(DSP)芯片集成有正交脉冲编码电路,并且数据处理速度快,实时性强。本文中提出的方法在电机控制专用DSP芯片TMS320 LF2407A上进行了实现。实验研究表明,可以在提高低速时的测速准确度的同时,提高系统的响应时间。该方法已经在自主研发的全数字伺服驱动系统中得到了成功应用。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

简要介绍了物流的发展现状 ,详细描述了基于CAN总线的物流拣选系统的结构、供电方式和参数设定方法 ,并为系统硬件设计中的电源转换、总线驱动和地址译码等公共电路以及总线控制器、电子标签和指示灯控制器等主要设备提供了设计方案 ,为系统软件设计中的C5 1编译、通信协议、命令类型和程序控制规划等问题给出了相应的解决方法 ,还与进口同类产品的性能和价格进行了比较

Relevância:

10.00% 10.00%

Publicador:

Resumo:

针对超大规模集成电路和片上系统设计中确定异步FIFO浓度的问题,根据异步FIFO运行时的属性提出FIFO动态参数模型,该模型包括FIFO饱和度、写入端和读出端数据传输率及上溢/下溢频率。在该模型的基础之上,分析异步FIFO的深度与动态参数之间的关系,采用功能仿真方法确定片上系统中异步模块之间数据传输所需FIFO的深度。对典型实例的分析表明,采用这种方法能够在保证系统数据通信性能的前提下,获得最小的FIFO深度,优化系统资源的使用。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

随着FPGA的发展,FPGA测试技术也得到了很快地发展。因为FPGA的结构和传统专用集成电路有着本质的区别,在FPGA中不能形成可测性设计电路,但它的可编程能力决定了其测试电路可以通过编程的方法来实现。本文讨论了XilinxXC4000系列FPGA中互连资源的自动测试方法。提出了一种新的测试资源坐标定位方法,使得测试软件能够将测试配置转换成器件配置,并搭建了硬件测试平台,实现实体FPGA芯片测试。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在线性电位器的电路设计中、电路前后级的输出和输入阻抗的影响以及使用与安装不当都可能引入非线性,造成电路和控制系统的精度达不到要求。为此,针对电位器的调节输出电压、限定调节范围、负载等效阻抗、细调等几种典型电路中的传递函数与非线性响应,通过实验给出了线性和非线性输出响应曲线。阐述了实际应用中如何避免和减少非线性的影响。