200 resultados para ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY(ESI-MSn)
Resumo:
A method for the determination of impurity elements in high purity cadmium by inductively coupled plasma mass spectrometry was developed. The spectral interference arising from Cd was discussed and the magnitude of interference by the polyatomic ion of Cd was compared. The effect of the high concentration Cd on the analyte signal was studied. The results showed that Cd possessed both significant suppression effects on the light mass elements signal and enhancement effects on the heavy mass elements signal,and the effects can be corrected by the use of internal standard elements. In this paper, Y and Bi was employed for the light mass elements and the heavy mass elements,respectively. As, Be, Co, Cu, Ga, Ge, Mn, Mo, Pb, Ni, Sr, Au, Tl, Th, V and U in high purity cadmium were determined. Detection limits are 0.005-0.052 mu g L-1,and the recoveries of standard addition are 82%-108%.
Resumo:
A method was developed for the determination of total mercury in biological samples. The effects of aqueous ammonia, ethylenediamine and triethanolamine on Hg signal intensity by inductively coupled plasma mass spectrometry has been evaluated and the possible mechanisms discussed. It has been proved that the signal intensity of Hg significantly increases with adding, in the presence of small amounts of aqueous ammonia, ethylenediamine or triethanolamine. The normalized intensity (the signal intensity ratio with amine and without amine) of Hg increases as the concentration of aqueous ammonia, ethylenediamine or triethanolamine increases, but the degree of enhancement of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The normalized intensity of Hg with aqueous ammonia, ethylenediamine and triethanolamine decreases as the nebulizer flow rate increases, but decreasing degree of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The higher the RF powers the higher the normalized intensity of Hg at the same nebulizer flow rate. The addition of aqueous ammonia, ethylenediamine and triethanolamine into analytical solutions significantly improved the transport efficiency of Hg. The detection limit of Hg is improved about ten times by the addition of ethylenediamine or triethanolamine under the optimum experimental parameters. The method has been used to determine mercury in biological standard reference materials (SRM). The analytical results are very close to the certified values and the determined values for similar samples.
Resumo:
Resonance electron capture mass spectrometry, in which an additional information coordinate, the energy of electron capture, is applied, has a high sensitivity and a high specificity. It is extensively used to study the structure elucidation, the mechanism of ion formation and the detection, identification and quantification of organic substances in mixture.
Resumo:
A method for the determiantion of rare earth elements in biological sampels by inductively coupled plasma mass spectrometry was developed. Oxide ion yield of the rare earth elements (RFE) decreased with the increasing of RF power and the sampling depth, or with the decreasing of carrier gas flow rate. The spectral interference arising from (PrO)-Pr-141-O-16 on Gd-157 must be corrected. if the concentration of Ba was high enough, it was necessary to correct the spectral interference arising from (BO)-B-135-O-16 on Eu-151, and it was not necessary to correct spectral interference arising from (NdO)-Nd-143-O-16 on Tb-159 etc. in the biological samples under the selected operation parameters. In the biological sample, the major matrix elements, such as K, Na and Ca, result in the suppression of REEs signals and the suppression degree of the Ca is grezter than that of the K and Na. The mussel sample was digested by thd dry ashing, wet digestion with HNO3 + H2O2 and HNO3 + HClO4, respectively. The analytical results of REEs were consistent with each other. Detection limits for REEs are 0.001 similar to 0.013 mu g/L. Recoveries of standard addition are 91.7% similar to 125%. REEs in biological samples were determined directly without separation and preconcentration procedure.
Resumo:
A method for the analysis of mussel standard reference material by inductively coupled plasma atomic emission spectrometry( ICP-AES) and inductively coupled plasma mass spectrometry(ICP-MS) was developed. K, Na, Ca, Mg, P, Al, Fe, Zn, Mn and Sr were determined by ICP-AES and As, B, Cd, Co, Cr, Cu, Ga, Ge, Mn, Mo, Ni, Pb, Se, Sr, U and V by ICP-MS, The interference coefficients at the Mn-55, Se-78, Cu-63, Co-59, Ni-58, Ni-60, As-75, Se-77, V-51, Cr-53 and Cr-52 originating from polyatomic ion of the matrix elements (KO)-K-39-O-16, K-39(2), (ArNa)-Ar-40-Na-23, (CaO)-Ca-43-O-16, (CaO)-Ca-42-O-16, (CaO)-Ca-44-O-16, (PO2)-P-31-O-16, (ArCl)-Ar-40-Cl-35, (ArCl)-Ar-40-Cl-37, (ClO)-Cl-35-O-16, (ClO)-Cl-37-O-16 and (ArC)-Ar-40-C-12 were determined under the selected operation parameters. The major matrix elements, such as K, Na and Ca, result in the suppression of analytes signals. The apparent concentration at the significant biological element which was produced by the different digestion methods, (.) HNO3 + H2O2 (3 + 2), HNO3 + HClO4 (3 + 0.5) and HNO3 + H2SO4 (3 + 0.5),was determined. The sample digested by HNO3 + H2O2 did not give rise to interfere on the analyte, and the backgrounds of Se-77, Ga-69, Zn-67, As-75, V-51, Cr-53 and Cr-52 were increased by HNO3 + HClO4 digestion method, that affected the determination of these elements, especially the monoisotope As and V. Sample digested by HNO3 + H2SO4 increased the backgrounds at Cu-65, Zn-64 and Zn-67. Detection limits of ICP-AES are 0.001 similar to 0.75 mg/L and those of ICP-MS are 0.005 similar to 1.01 mu g/L. The relative standard derivations of ICP-AES and ICP-MS are 2.7% similar to 12.8%, 3.4% similar to 24.8%, respectively.
Resumo:
Incubated solutions containing glutathione (GSH) and alpha- or beta-cyclodextrins (CDs) were analyzed using electrospray mass spectrometry and tandem mass spectrometry, The results suggest that both CDs can catalyze oxidation of GSH to the oxidized glutathione (GSSG). The collision-induced dissociation (CID) of the 1:1 and 1:2 (CD/GSH) and 1:1 (CD/GSSG) complexes reveals the strong interactions of the CDs with the peptides tested. The 1:2 (CD/GSH) complex is considered to be the oxidation reaction intermediate, which indicates that the three-dimensional structure of the complexed two GSHs in CD complexes Is different from that of the proton-bound GSH dimer, The oxidation product, GSSG, Is also observed in the CID spectrum of the singly charged 1:1 (CD/GSH) complex, suggesting that a complex ion-complex ion reaction occurs by forming a doubly charged complex dimer, as a result of the ability of ion trap to accumulate and activate ions. The observations indicate that ion trap mass spectrometry can be used to explore cyclodextrin-catalyzed reactions and to carry out complex gaseous chemistry research. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
Due to the difference in reactivity of enantiomers with chiral reagents, it was found that in the Fast Atom Bombardment (FAB) mass spectra of enantiomer mixtures of R-alpha-phenylethylamine and S-alpha-phenylethylamine with a chiral reagent S-phosphorsaeure-(1,1'-bi-naphthyl-2,2'-diylester) (BNP acid), the relative abundance of the characteristic ion is linearly related to the composition of the mixture. We have, therefore, proposed a possible method for the determination of the optical purity of enantiomers by mass spectrometry.
Resumo:
It is found that in the fast atom bombardment (FAB) mass spectra R-alpha-phenylethylamine and S-alpha-phenylethylamine can be clearly distinguished by S-1,1'-binaphthyl-2, 2'-diylhydrogenphosphate (S-BNP), Mixture of R-alpha-phenylethylamine and S-alpha-phenylethylamine also be tested and the relative abundance of the characteristic ion of mixture is related to the composition of the mixtute. We have therefore proposed a possible method to determine the optical purity of alpha-phenylethylamine.
Resumo:
In fast atom bombardment, two fullerenols C-60(OH)(x) (x=13-15) and C-60(OH)(x) (x-24-26) gave rise to a group of ions centered at C-118 with intervals of 24 mass units in the high mass region. In contrast, no such ions appeared in the mass spectra of pure C-60, C-70 and other fullerene derivatives such as C-60(C6H5)(10), under the same conditions. It is proposed that the pinacol rearrangement of C-60(OH)(2), resulting from partial rupture of the polyhydroxy molecules, produces C-59 with two carbon atoms bearing an unpaired electron, and that dimerization of this reactive intermediate is responsible for the formation of the predominant product C-118. An intermolecular nC(2) transfer process is used to explain the symmetrical abundance distribution of these product ions in the spectra of fullerenols.
Resumo:
Biphenyl derivatives undergo extensive intraannular substituent migrations and subsequent intramolecular ipso substitutions giving rise to a fluorenyl cation and a biphenylene radical cation as common products in mass spectrometry. For biphenyls bearing an alkyl group, interannular substituent migration resulting in a substituted tropylium ion is also observed. Electron-withdrawing groups are found to be much more favourable to these reactions than the electron-donating ones.
Resumo:
Thermal decomposition processes of poly(thio-1,4-phenylene) (PPS), polythiophene (PT) and polyaniline (PAn) were investigated by direct pyrolysis EI or CI mass spectrometry (DPMS). They can provide up to heptemer pyrolynates and give some structure properties. The results indicate that the thermal degradation all undergoes in radical decomposition, PPS pyrolyzes into linear and cyclic oligmers, but PT and PAn pyrolyze only into linear oligmers.
Resumo:
The thermal decomposition of polyaniline(PAn) and poly-o-toluidine(POT) was studied by means of direct pyrolysis mass spectrometry(DM) and MS/MS, The results showed that both benzene-diamine and quinone-diimine units were produced, and the intensities of fragments corresponding to quinone-diimine units increased as the oxidation degrees increased, The mechanism of thermal decomposition of PAn and POT was given for the first time.
Resumo:
The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds (trimethyltin, dibutyltin, tributyltin, diphenyltin and triphenyltin) in seawater samples. Agilent TC-C18 column was used for the separation, the mobile phase of HPLC was CH3CN : H2O: CH3COOH=65 : 23 : 12 (phi), 0.05% TEA, and pH value was adjusted to 3.0 by diluent ammonia. The flow rate was 0.6 mL . min(-1). Five mixed organotin compounds in a mix standard solution from 100 to 0.5 mu g . L-1 were applied for the method assessment. The experimental results indicate that the correlation coefficient of calibration curves (R-2) for each organotin compound was over 0.998 and the detection limits of the five organotin compounds were lower than 3 ng . L-1. Different mixed organic solvents including dichloromethane or toluene were used for extraction of organotin and the extraction condition of organotin from seawater was optimized. The 100 mL seawater acidized by hydrochloric acid was extracted by 10 mL carbon dichloride (CH2Cl2) with 2% tropolone for 10 min twice. Extracted organic solvents were mixed And blown to one drop by nitrogen with the rate of 1.7 mL . min(-1), then 1 mL acetonitrile was added to the drop for redissolving the organotin compounds. Finally, the mixed redissolution was filtered by 0.22 mu m organic filter membrane before analysis. it was found that the only organotin compound in seawater was triphenyltin (TPHT) and the content was 53.2 ng . L-1. The recoveries test from the standard addition for diphenyltin (DPHT), dibutyltin (DBT), tributyltin (TBT) and triphenyltin (TPHT) were over 80%. However, the recovery for trimethyltin (TMT) was relatively low and the value was 50%. The reason might be attributed to the decomposition or adsorption of those compounds during the extraction procedure. Further study on this subject is in progress.
Resumo:
The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry(HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds in the shellfish samples. Agilent TC-C-18 column was selected, mobile phase of the HPLC was CH3CN:H2O: CH3COOH = 65:23:12 (V/V), 0. 05% TEA, pH = 3.0 at flow rate 0.4 mL/min. Five mixed organotin standards from 100 mu g/L to 0. 5 mu g/L was used for the method evaluation. The experimental results indicate that the linearity (R-2) for each compound was over 0.998. The shellfish samples were treated by supersonic extraction with mobile phase for 30min. Four organotin compounds including dibutyltin (DBT), tributyltin (TBT), diphenyltin (DphT) and triphenyltin (TPhT) in shellfish samples were detected with method mentioned above. It was found that the domain compounds in the samples were tributyltin (TBT) and triphenyltin (TPhT). The recoveries test from the standard addition for trimethyltin (TMT tributyltin (TBT), and triphenyltin (TPhT) were, over 80%. However, the recoveries for diphenyltin (DPhT) and dibutyltin (DBT) were relatively low, 37.3% and 75.2% respectively. The reason might be attributed to the decomposition of those compounds during the extraction procedure. The further study on this subject is under the progress.