404 resultados para voltammetric determination


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A poly(vinyl chloride)(PVC)-based membrane of 15-crown-5 exhibits a good response for lead(II) ions over a wide concentration range. The response time of the sensor is 30 s and the membrane can be used for more than four months without observing any divergence. The selectivity of the sensor is comparable with those reported for other such electrodes. It was possible to determine lead in polluted waters using this electrode assembly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geochemical processes in estuarine and coastal waters often occur on temporally and spatially small scales, resulting in variability of metal speciation and dissolved concentrations. Thus, surveys, which are aimed to improve our understanding of metal behaviour in such systems, benefit from high-resolution, interactive sampling campaigns. The present paper discusses a high-resolution approach to coastal monitoring, with the application of an automated voltammetric metal analyser for on-line measurements of dissolved trace metals in the Gulf of Cadiz, south-west Spain. This coastal sea receives metal-rich inputs from a metalliferous mining area, mainly via the Huelva estuary. On-line measurements of dissolved Cu, Zn, Ni and Co were carried out on-board ship during an eight-day sampling campaign in the study area in June 1997. A pumping system operated continuously underway and provided sampled water from a depth of ca. 4 m. Total dissolved metal concentrations measured on-line in the Gulf of Cadiz ranged between <5 nM Cu (<3 nM Ni) ca. 50 km off-shore and 60–90 nM Cu (5–13 nM Ni) in the vicinity of the Huelva estuary. The survey revealed steep gradients and strong tidal variability in the dissolved metal plume extending from the Huelva estuary into the Gulf of Cadiz. Further on-line measurements were carried out with the automatic metal monitor from the bank of the Odiel estuary over a full tidal cycle, at dissolved metal concentrations in the μM range. The application confirmed the suitability of the automated metal monitor for coastal sampling, and demonstrated its adaptability to a wide range of environmental conditions in the dynamic waters of estuaries and coastal seas. The near-real time acquisition of dissolved metal concentrations at high resolution enabled an interactive sampling campaign and therefore the close investigation of tidal variability in the development of the Huelva estuary metal plume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variety of short-lived, reactive chemical species (i.e. free radicals and excited state species) are known to be photochemically produced in natural waters. Some of these transients may strongly affect chemical and biological processes, and they have been implicated in the degradation of organic pollutants and natural organic compounds in aqueous environments. Previous studies demonstrated that the highly reactive hydroxyl radical (OH) is photochemically formed in seawater. However, the quantitative importance of this key species in the sea has not been previously studied because of past analytical limitations. By using a highly sensitive probe based on α-H atom abstraction from methanol, we were able to measure production rates and steady-state concentrations of photochemically produced OH radicals in coastal and open ocean seawater and freshwaters. The validity of the method was tested by intercalibrating with an independent, OH-specific reaction, hydroxylation of benzoic acid, and also by competition kinetics experiments. Our OH production rates and steady-state concentrations for freshwaters are in excellent agreement with those measured by previous investigators for similar waters. In contrast, for seawater, the values we measured are 1–3 orders of magnitude higher than previously predicted by models, indicating that there is a major unknown photochemical OH source (s) in seawater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with determining points of zero charge of natural and Na+-saturated mineral kaolinites using two methods: (1) acid-base potentiometric titration was employed to obtain the adsorption of H+ and OH- on amphoteric surfaces in solutions of varying ionic strengths in order to determinate graphically the point of zero net proton charge (PZNPC) defined equally as point of zero salt effect (PZSE); (2) mass titration curve at different electrolyte concentrations in order to estimate PZNPCs by interpolation and to compare with those determined by potentiometric titrations. The two methods involved points of zero charge approximately similar for the two kaolinites between 6.5-7.8, comparable to those reported previously and were in the range expected for these clay minerals. The comparison of potentiometric surface titration curves obtained at 25 °C and those published in the literature reveals significant discrepancies both in the shape and in the pH of PZNPCs values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

zero point of charge of freshly precipitated cu(oh)2 has been determined to lie at pH 7.7 by means of microclectrophoresis technique. Day aged hydroxide shows an acid zpc shift to pH 7.3. these experimental values approximate the equivalence points of cu+ and oh_ ,which can be estimated from the solubility diagram constructed fo gu(oh)2 and cuo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

the salt ritration metod was evaluated as a method to determine zpc in comparison with the potentiometric titration method for 26 soil with variable charge clays,i.e.,Oxisols and Ultisols from Thailand and Andisols from Japan. In addition to the determination of ST-pH0 as the zero point of charge, a calculation procedure was adopted here in order to acquire more information from the titration curve . fuithermore, for the purpose of cross-checking of zpc determined by the pt method, the st procedure was successively applied to the samples analyzed by the pt method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time, we report a sensitive and selective method to detect Cu2+ based on the electrochemiluminescence quenching of CdTe quantum dots (QDs) in aqueous solution. The mercaptosuccinic acid (MSA) protected CdTe QDs were prepared and characterized with UV, fluorescence and ECL. The anodic ECL quenching mechanism was attributed to the fact that MSA capping was removed from the surface of the CdTe QDs and preferentially bound with Cu2+. The displacement of MSA capping layer created imperfections on the CdTe QDs surface, and eventually led to the ECL quenching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new kind of bismuth film modified electrode to sensitively detect trace metal ions based on incorporating highly conductive ionic liquids 1-butyl-3-methyl-imidazolium hexafluorophosphate (BMIMPF6) in solid matrices at glassy carbon (GC) was investigated. Poly(sodium 4-styrenesulfonate) (PSS), silica, and Nafion were selected as the solid matrices. The electrochemical properties of the mixed films modified GC were evaluated. The electron transfer rate of Fe(CN)(6)(4-)/Fe(CN)(6)(3-) can be effectively improved at the PSS-BMIMPF6 modified GC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we investigated the analytical performances of the bismuth-modified zeolite doped carbon paste electrode (BiF-ZDCPE) for trace Cd and Pb analysis. The characteristics of bismuth-modified electrodes were improved greatly via addition of synthetic zeolite into carbon paste. To obtain high reproducibility and sensitivity, optimum experimental conditions for bismuth deposition Were Studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we attempt to construct a simple and sensitive detection method for both phenolic compounds and hydrogen peroxide, with the successful combination of the unique property of quantum dots and the specificity of enzymatic reactions. In the presence Of H2O2 and horseradish peroxidase, phenolic compounds can quench quantum dots' photoluminescence efficiently, and the extent of quenching is severalfold to more than 100-fold increase. Quinone intermediates produced from the enzymatic catalyzed oxidation of phenolic compounds were believed to play the main role in the photoluminescence quenching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we attempt to develop a sensitive detection method for glucose with the combination of the unique optical property of quantum dots and the specificity of enzymatic reactions. With glucose and hydroquinone as substrates, benzoquinone that intensively quenches the photoluminescence of quantum dots can be produced via the catalysis of bienzyme (glucose oxidase and horseradish peroxidase) system. A relatively low detection limit of 1.0 x 10(-8) mol/L can be achieved. Two linear ranges from 1.0 x 10(-6) to 1.5 x 10(-4) M and from 1.5 x 10(-4) to 1.0 x 10(-3) M were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we described a simple and rapid method, capillary electrophoresis with electrochemiluminescence (CE-ECL) detection using tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)), to simultaneously detect pethidine and methadone. Analytes were injected to separation capillary of 67.5 cm length (25 mu m i.d., 360 mu m o.d.) by electrokinetic injection for 10 s at 10 kV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-walled carbon nanohorn (SWCNH) paste electrode was used for amperometric determination of concentrated hydrogen peroxide, and was compared with other carbon electrodes. The calibration plots are linear from 0.5 to 100 mM at activated SWCNH paste electrode and edge plane graphite (EPG) electrode. In contrast, the calibration plots are linear only at concentrations lower than 45 mM at graphite paste electrode, multi-walled carbon nanotube paste electrode, and glassy carbon electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the fabrication of an efficient amperometric hydrogen peroxide sensor with favorable properties is presented. Prussian blue (PB) was catalytically synthesized by Pt nanoparticles (Pt-nano) from ferric ferricyanide aqueous solution to form PB@Pt-nano hybrid, and it was confirmed by transmission electron microscope (TEM) and optical spectra. The electrochemical behavior of PB@Pt-nano was highly improved through its integration with poly(diallyldimethylammonium chloride) modified carbon nanotubes (PCNTs).