211 resultados para Semi-analytical
Resumo:
The analytical solution of a multidimensional Langevin equation at the overdamping limit is obtained and the probability of particles passing over a two-dimensional saddle point is discussed. These results may break a path for studying further the fusion in superheavy elements synthesis.
Resumo:
目前加速速度范围在0.01c—0.3c的粒子的超导腔主要使用四分之一波长腔型。用于不同加速器上的频率范围在50—240MHz的四分之一波长腔在建造或者预研中。这种腔型的一个不足是其横向电磁成分会造成束流偏转效应,从而导致发射度的增长和束流的溢漏,在强流重离子加速器中这种效应尤为严重。对中国科学院近代物理研究所超导直线加速器中的频率为80.5和161MHz的四分之一波长腔的偏转效应进行了分析,计算结果表明,在四分之一腔体的设计时需要考虑到束流偏转的修正,这通常需要在漂移管端面上削适当大小的倾角来实现。
Resumo:
In this paper, the capabilities of laser-induced break down spectroscopy (LIBS) for rapid analysis to multi-component plant are illustrated using a 1064 nm laser focused onto the surface of folium lycii. Based on homogeneous plasma assumption, nine of essential micronutrients in folium lycii are identified. Using Saha equation and Boltzmann plot method electron density and plasma temperature are obtained, and the irrelative concentration (Ca, Mg, Al, Si, Ti, Na, K, Li, and Sr) are obtained employing a semi-quantitative method.
Resumo:
The dynamic flow profiles and separation performances in conically shaped preparative liquid chromatographic columns (inlet i.d. larger than outlet i.d.) with three different angles (7, 10 and 15degrees) were studied and compared with cylindrical column of the same length and internal volume. The shapes of dynamic flow profiles were studied by on-column visualization method. The transparent chromatographic columns made of polymethyl methacrylate (PMMA), packed with C-18 bonded silica, were immerged into a cubic pool filled with glycerol to eliminate the cylindrical and conical lens effect. The flow profiles of colored iodine solution in the columns were observed clearly using cyclohexane as mobile phase since the refractive indices of C-18, column wall and the mobile phase are very close. In the conical column of 15degrees (20-7 mm i.d.) the mobile phase in the central region migrated slower than in wall region as it moved toward the column outlet, while in the conical column of 7degrees (17-11 mm i.d.) the mobile phase in the central region migrated faster than in wall region just like in cylindrical column. We found that a plug-like flow profile was generated in the conical column of 10degrees (18-9 mm i.d.) during the whole migration process. A carmine and brilliant blue mixture was used as a probe to test the separation ability of the columns. The resolutions of the two compounds on the conical column of 7, 10, 15degrees and on the cylindrical column were 0.6, 1.57, 1.29 and 0.8, respectively. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The dynamic flow profiles and column efficiencies in conically shaped semi-preparative liquid chromatographic columns (inlet ID larger than outlet ID) with two different conical angles (7degrees and 15degrees) were studied. The dynamic flow profiles were studied by an on-column visualization method. Conical columns were compared with cylindrical column of the same length and internal volume. The results showed that the flow profile of a sample band in the conical column of 7degrees (50 mm x 17 mm --> 11 mm ID) was parabolic in shape. The sample band migrated slower in the wall region than in the central region, as in the cylindrical column (50 mm x 14 mm ID). However, the sample band in the conical column of 15degrees (50 mm x 20 mm --> 7 mm ID) migrated slower in the central region than in the wall region, resulting in a reverse parabolic flow profile, in contrast to that in cylindrical column. This indicated that a flat flow profile might be realized in a conical column with a conical angle between 7degrees and 15degrees. The conical column of 15degrees had the highest column efficiency among the three columns under the same conditions. Compared with the cylindrical column packed with identical packing material, the conical column of 15degrees had 22%-45% higher column efficiency and 11%-27% higher peak height.
Resumo:
set of energies at different internuclear distances for the ground electronic state and two excited electronic states of NaH molecule have been calculated using valence internally contracted multireference configuration interaction(MRCI) including Davidson correction and three basis sets. Then, a potential energy curve (PEC) for each state was determined by extrapolating MRCI energies to the complete basis sets limit. Based on the PECs, accurate vibrational energy levels and rotational constants were determined. The computational PECs are were fitted to analytical potential energy functions using the Murrell-Sorbie potential function. Then, accurate spectroscopic parameters were calculated. Compared with experimental results, values obtained with the basis set extrapolation yield a potential energy curve that gives accurate vibrational energy levels, rotational constants and spectroscopic parameters for the NaH molecule. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The equilibrium properties and potential energy curves of the ground electronic state of CaF have been calculated using the Brueckner Doubles calculation with a triples contribution added [BD(T)] and the gradient-corrected density functional theory with three-parameter exact exchange mixing (B3LY-P) method, with 6-311 + G*,6-311 + G(2df,2pd) and 6-311 + G(3df,3pd) basis sets. All the computational PECs are fitted to analytical potential energy functions using Murrell-Sorbie, Huxley and Tang-Toennies potentials. Based on this, the spectroscopic parameters are calculated, and then compared with some other theoretical and experimental data. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
A comprehensive, critical and up-to-date review of analytical methods developed during the last decade for metals present in sea water is presented. Separate sections are devoted to singular and multimetal determinations. Furthermore, a critical comparison of relative merits or demerits of a particular procedure is made in terms of sensitivity, selectivity and precision. Various aspects of analysis of sea water samples for metals are summarized, and the future trends are discussed.
Resumo:
“Dissolved” (< 0.4 μm filtered) and “total dissolvable” (unfiltered) trace element samples were collected using “clean” sampling techniques from four vertical profiles in the eastern Atlantic Ocean on the first IOC Trace Metals Baseline expedition. The analytical results obtained by 9 participating laboratories for Mn, Fe, Co, Ni, Cu, Zn, Cd, Pb, and Se on samples from station 4 in the northeast Atlantic have been evaluated with respect to accuracy and precision (intercomparability). The data variability among the reporting laboratories was expressed as 2 × SD for a given element and depth, and was comparable to the 95% confidence interval reported for the NASS seawater reference standards (representing analytical variability only). The discrepancies between reporting laboratories appear to be due to inaccuracies in standardization (analytical calibration), blank correction, and/or extraction efficiency corrections.Several of the sampling bottles used at this station were not adequately pre-cleaned (anomalous Pb results). The sample filtration process did not appear to have been a source of contamination for either dissolved or particulate trace elements. The trace metal profiles agree in general with previously reported profiles from the Atlantic Ocean. We conclude that the sampling and analytical methods we have employed for this effort, while still in need of improvement, are sufficient for obtaining accurate concentration data on most trace metals in the major water masses of the oceans, and to enable some evaluation of the biogeochemical cycling of the metals.
Resumo:
This review presents the latest advances in the application of microwave energy to analytical chemistry. The fundamental principles of microwave field interaction with the matter are presented and their significance for the chemist is discussed, followed by the basic principles of microwave equipment construction and operation. Examples of the techniques that utilized microwave energy for digestion, extraction, chemical reaction, preconcentration, and desorption of the analytical sample are presented. A separate section describes the examples of usage of microwave technology in catalysis, environmental, and nuclear chemistry and engineering.
Resumo:
Gaseous and particulate semi volatile carbonyls have been measured in urban air using an annular denuder sampling system. Three dicarbonyls, five aliphatic aldehydes and two hydroxy carbonyls were observed. Concentrations of other biogenic and anthropogenic volatile organic compounds (VOCs), SO2, CO, NO2 and particle concentration were also measured. Estimated gas-aerosol equilibrium constants for the carbonyls showed an inverse correlation with the concentrations of anthropogenic pollutants such as benzene, isopentane and SO2. This suggests that the increase in the fraction of non-polar anthropogenic particles in the atmosphere could change the average property of the ambient aerosols and drive the gas particle equilibrium of the carbonyls to the gas phase. This trend is uncommon in remote forest air. In this study, we examined the factors controlling the equilibrium in the polluted atmosphere and show that there is a difference in gas-aerosol partition between polluted and clean air.
Resumo:
This paper presents results of 2 years (from January 2005 to December 2006) of measurement of N2O fluxes from the native and grazed Leymus chinensis (LC) steppes in Inner Mongolia, China using the static opaque chamber method. The measurement was at a frequency of twice per month in the growing season and once per month in the non-growing season. In addition, the possible effect of water-heat factors on N2O fluxes was statistically analyzed. The results indicated that there were distinct seasonal patterns in N2O fluxes with large fluxes in spring, summer, and autumn but negative fluxes in winter. The annual net emission of N2O ranging from 0.24 to 0.30 kg N2O-N ha(-1) and from 0.06 to 0.26 kg N2O-N ha(-1) from the native and grazed LC steppe, respectively. Grazing activities suppressed N2O production. In the growing season, soil moisture was the primary driving factor of N2O fluxes. The high seasonal variation of N2O fluxes was regulated by the distribution of effective rainfall, rather than precipitation intensity. Air temperature or soil temperature at 0, 5, and 10 cm depth was the most restricting factor of N2O fluxes in the non-growing season.