169 resultados para Ce^3


Relevância:

30.00% 30.00%

Publicador:

Resumo:

(YSZ)ZrO_2-Y_2O_3(88:12):CeO_2(0.01,0.3,0.5wt%),Fe:O:0.03wt%+CeO_20.01wt%,CoO(0.1,0.3wt%)250310nm,,YSZYSZ400600nm,YSZ,(Y_((zr),V_n)Fe~(3+)ESR,YSZ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel labeling reagent 1-(2-naphthyl)-3-methyl-5-pyrazolone (NMP) coupled with capillary electrophoresis (CE) with DAD detection for the determination of carbohydrates has been developed. The chromophore in the 1-phenyl-3-methyl-5-pyrazolone (PMP) reagent is replaced by naphthyl functional group, which results in a reagent with very high molar absorptivity (epsilon(251nm) = 5.58 x 10(4) L mol(-1) cm(-1)). This pen-nits NMP-labeled carbohydrates to be detected with UV absorbance in standard 50-mu m-i.d. fused silica capillaries by zone electrophoresis. in this mode, nanomolar concentrations of detection limits are obtained. The method for the derivatization. of carbohydrates with NMP is simplified. The derivatization reaction is rapid and mild in the presence of ammonia catalyst without further transfer steps. Nine monosaccharide derivatives such as mannose, galacturonic acid, glucuronic acid, rhamnose, glucose, galactose, xylose, arabinose and fucose can successfully be detected in CE mode. Good reproducibility can be obtained with relative standard deviation (R.S.D.) values of the migration times and peak area, respectively, from 0.44 to 0.48 and from 3.2 to 4.8. Furthermore, the developed method has been successfully applied to the analysis of carbohydrates in the hydrolyzed rape bee pollen samples. (C) 2008 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pre-column derivatization method for sensitive determination of oligopeptides, using the tagging reagent 2-(9-carbazole)ethyl chloroformate (CEOC-Cl) followed by capillary electrophoresis (CE) with diode-array detection, has been developed. Maximum yield close to 100% were observed when a three to fourfold molar excess of reagent was used at pH 9.0-10.0. Excess reagent was extracted with n-hexane-ethyl acetate 9:1-10:1 (v/v); this enabled direct analysis using CE with no significant disturbance from the major fluorescent reagent degradation by-products. The effects on the results of buffer pH and of SDS and organic modifier concentrations were examined. Good baseline resolution in the separation of five CEOC-peptides was achieved with a 48.5-cm total length (effective length 40 cm) 50-mu m inner diameter capillary column.