190 resultados para COBALT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Catalysts with spinel structure derived from Hydrotalcite-like Compounds (HTLcs) containing cobalt have been investigated in NO catalytic reduction by Co. It was found that catalysts with spinel structures derived from HTLcs had obviously higher activity than that prepared from general methods. A two-step reaction was observed during the reaction curse: NO was first reduced to N2O by Co, and with the increase of temperature, the N2O was reduced to N-2. The reactivity of the catalysts studied increased with the amount of cobalt-content in the catalyst, and decreased with the calcination temperature. The crystal defect would play an important role in the reaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Detection of DNA is a very important task for molecular biology and biomedical field. We have investigated electrochemical behavior of double-stranded DNA and single-stranded DNA adsorbed on conducting polymer modified electrode in presence of cobalt complex. The possibility of using such electrode as gene detector is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ferric trisacetylacetonate has been deposited within the zeolite MCM-41 and the product characterized by XRD and IR. In water at pH 7 it catalyzes the oxidation of phenol by H2O2, giving 58% conversion in 1 h at 50 degrees C: products are catechol (66%), hydroquinone (27%) and benzoquinone (7%). Other oxidants and solvents are much less effective. UV-VIS spectra suggest a radical substitution mechanism, and a pollution-free process for phenol hydroxylation is now possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurement of iron and manganese is very important in evaluating the quality of natural waters. We have constructed an automated Fe(II), total dissolved iron(TDI), Mn(II), and total dissolved manganese(TDM) analysis system for the quality control of underground drinking water by reverse flow injection analysis and chemiluminescence detection(rFIA-CL), The method is based on the measurement of the metal-catalyzed light emission from luminol oxidation by potassium periodate. The typical signal is a narrow peak, in which the height is proportional to light emitted and hence to the concentration of metal ions. The detection limits were 3 x 10(-6) mu g ml(-1) for Fe(II) and the linear range extents up to 1.0 x 10(-4) and 5 x 10(-6) mu g ml(-1) for Mn(II) cover a linear range to 1.0 x 10(-4) mu g ml(-1). This method was used for automated in-situ monitoring of total dissolved iron and total dissolved in underground water during water treatment. (C) 1997 Elsevier Science B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Co(salen)-Nafion modified electrode was prepared by immersing a glassy carbon electrode coated with the Nafion film into the aqueous solution with saturated Co(salen), The modified electrode showed a stable electrochemical reaction of Co(salen) at about 0 V(vs, SCE), The result of XPS indicated the valence of cobalt in Co(salen) changes from +2 before to +3 after Co(salen) enters the Nafion film, It is due to forming axis coordination of cobalt with sulfonic group in Nafion film, It was found that the mode of electron transfer in Co(salen)-Nafion modified electrode was controlled by physical diffusion and electron hopping, It was also found that the modified electrode could catalyze the reduction of O-2 to H2O2. The real catalyst may be the adduct of Co-I(salen) and O-2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of mechanical alloying on the solubility in a Ag-Gd solid solution have been investigated. The study shows that the solubility of Gd in Ag can be extended to about 5 at. % Gd by mechanical alloying from the equilibrium solubility of less than 0.95 at. % Gd. Ag85Gd15 prepared by mechanical alloying exhibits a spin-glass-type transition at similar to 5 K. A Curie-Weiss behavior at higher temperatures and x-ray patterns of the material indicate that Gd atoms are either dissolved in the Ag matrix or in the form of small clusters of diameters of a few nanometers;

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A chemically modified electrode (CME) constructed by adsorption of aquocobalamin (VB12a) onto a glassy carbon electrode surface was demonstrated to catalyze the electro-oxidation of cysteine, a sulfhydryl-containing compound. The sulfhydryl oxidation occured at 0.54-0.88 V vs. Ag/AgCl depending on pH value (3.0-10.0). The electrocatalytic behavior of cysteine is elucidated with respect to solution pH, operating potential and other variables as well as the CME preparation conditions. When used as the sensing electrode in flow injection amperometric detection, the CME permitted detection of the compound at 0.8 V. The detection limit was 1.7 pmol. The linear response range went up to 1.16 nmol. The stability of the CME was shown by RSD (4.2%) over 10 repeated injections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An assay procedure utilizing pulsed amperometric detection at a platinum-particles modified electrode has been developed for the determination of cysteine and glutathione in blood samples following preliminary separation by reversed-phase liquid chromatography. A chemically modified electrode (CME) constructed by unique electroreduction from a platinum-salt solution to produce dispersed Pt particles on a glassy carbon surface was demonstrated to catalyze the electo-oxidation of sulfhydryl-containing compounds: DL-cysteine (CYS), reduced glutathione (GSH). When used as the sensing electrode in flow-system pulsed-amperometric detection (PAD), electrode fouling could be avoided using a waveform in which the cathodic reactivation process occurred at a potential of - 1.0 V vs. Ag/AgCl to achieve a cathodic desorption of atomic sulfur. A superior detection limit for these free thiols was obtained at a Pt particle-based GC electrode compared with other methods; this novel dispersed Pt particles CME exhibited high electrocatalytic stability and activity when it was employed as an electrochemical detector in FIA and HPLC for the determination of those organo-sulfur compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reduction of hydrogen peroxide at a glassy carbon (GC) electrode modified with sigma-bonded pyrrole iron(III) octaethylporphyrin complex, (OEP)Fe(Pyr), was studied by cyclic voltammetry and a rotating disk electrode. In 0.1N NaOH solution, it is shown that such an (OEP)Fe(Pyr)/GC electrode has a significant catalytic activity towards hydrogen peroxide reduction (E(D) = -0.80 V, k = 0.066 cm s(-1)); however, the electrode stability is low. The deactivation is observed when the reaction charge (Q) is passing through the (OEP)Fe(Pyr)/GC disk electrode. A linear rotation scan method is applied to study the kinetic process by determining the disk electrochemical response (i(D)) to rotation rate (omega) at a definite disk potential (E(D)). Considering that the number of adsorbed electroreduced catalyst molecules (Red) varies according to the disk potential, a factor theta(= Gamma(Red)/(Gamma(Red) + Gamma(Ox))) is introduced to describe the electrode surface area fraction for electroreduced species. The obtained Koutecky-Levich equation is applicable whatever the potential is.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dicyanobis(1,10-phenanthroline)iron(II)-modified glassy carbon electrodes were shown to exhibit an electrocatalytic response for the oxidation of acetaminophen with a decrease of 100 mV in the potential required. It can also inhibit the oxidation of ascor

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the presence of OH- anions, electrochemical redox reactions of cobalt tetraphenylporphyrin (TPP)Co were investigated in EtCl2 solution by thin-layer cyclic voltammetry and spectroelectrochemistry. In the pressence of OH-, OH- was axially coordinated to

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Amperometric biosensors based on surface modifications of electrodes are described. Cobalt porphyrins modified on glassy carbon and carbon fiber electrodes can greatly decrease the overpotential and increase the sensitivity of detection due to EC electroc

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrocatalytic oxidation of sulfhydryl compounds was effective on a copper hexacyanoferrate (CuHCF) film glassy carbon electrode, at a significantly reduced overpotential (0.55 to 0.65 V) and for a broader pH range (2.0 to 7.0). The electrocatalysis was

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemically modified electrodes prepared by adsorbing prussian blue on a glassy carbon electrode are shown to catalyse the electro-oxidation of cysteine, N-acetylcysteine and glutathione in acidic media. The catalytic response is evaluated with respect to the potential scan rate, the solution pH, the concentration dependence, and other variables. Covering the electrode with Nafion(R) film improved the stability and reproducibility in liquid chromatography with electrochemical detection to the extent that repetitive sample injections produced relative standard deviations of less than 5% over several hours of operation. The limit of detection was 4 pmol for cysteine, 33 pmol for glutathione and 61 pmol for N-acetylcysteine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Research on Electroanalytical chemistry in China started mainly from the beginning of new China in 1949. It has already good basis and development nowadays. A review with references to the end of seventies has been published in "Reviews in Analytical Chemistry" 1) and in a book titled "Fifty years of Chinese Chemistry" edited by the Chinese Chemical Society in 1985 2). Since then more than thousand papers have been published, and it is impossible and also not necessary to describe all of them. This review only deals with the main progress of electroanalytical chemistry in China in recent years. Some new developed methodologies will be reviewed by S. Dong in the next article.