171 resultados para PLASMA-MASS SPECTROMETRY
Resumo:
The extract of Adinandra nitida leaves, named as Shiyacha in China, was studied by high performance liquid chromatography (HPLC)-ultraviolet detection-electrospray ionisation (ESI) tandem mass spectrometry (MS). Under the optimized condition, the analysis could be finished in 45 min on a Hypersil C18 column combined with negative ion detection using information-dependent acquisition (IDA) mode of a Q TRAP (TM) instrument. Six flavonoids were identified as epicatechin, rhoifolin, apigenin, quercitrin, camellianin A, and camellianin B among which rhoifolin was for the first time found in Shiyacha. And the fragment pathways of these flavonoids were elucidated. Furthermore, with epicatechin, rhoifolin, and apigenin as markers, the quality control method for Shiyacha and its relevant product was firstly established. Calibration linearity was good (R-2 > 0.9992) over a three to four orders of magnitude concentration range with an S/N = 3 detection limit of 2.5 ng. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 muL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized. (C) 2004 American Society for Mass Spectrometry.
Resumo:
Direct-injection electrospray ionization mass spectrometry in combination with information-dependent data acquisition (IDA), using a triple-quadrupole/linear ion trap combination, allows high-throughput qualitative analysis of complex phospholipid species from child whole blood. In the IDA experiments, scans to detect specific head groups (precursor ion or neutral loss scans) were used as survey scans to detect phospholipid classes. An enhanced resolution scan was then used to confirm the mass assignments, and the enhanced product ion scan was implemented as a dependent scan to determine the composition of each phospholipid class. These survey and dependent scans were performed sequentially and repeated for the entire duration of analysis, thus providing the maximum information from a single injection. In this way, 50 different phospholipids belonging to the phosphatidylethanolamine, phosphatidylserine, phosphatidylinositol, phosphatidylcholine and sphingomyelin classes were identified in child whole blood. Copyright (C) 2005 John Wiley & Sons, Ltd.
Resumo:
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GUMS)and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC x GC/TOFMS), respectively. In the GUMS analysis, serially coupled columns were used. By comparing the GUMS results with GC x GC/TOFMS result,,, many more components in the essential oil could be found within the two-dimensional separation space of GC x GC. The quantitative determination of components in the essential oil was performed by GC x GC with flame ionization detection (FID), using a method of multiple internal standards calibration, (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A quantitative analysis of the individual compounds in tobacco essential oils is performed by comprehensive two-dimensional gas chromatography (GC x GC) combined with flame ionization detector (FID). A time-of-flight mass spectrometer (TOF/MS) was coupled to GC x GC for the identification of the resolved peaks. The response of a flame ionization detector to different compound classes was calibrated using multiple internal standards. In total, 172 compounds were identified with good match and 61 compounds with high probability value were reliably quantified. For comparative purposes, the essential oil sample was also quantified by one-dimensional gas chromatography-mass spectrometry (GC/MS) with multiple internal standards method. The results showed that there was close agreement between the two analysis methods when the peak purity and match quality in one-dimensional GC/MS are high enough. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for environmental analysis has been mainly focused on qualitative analysis of high-mass molecules, such as toxins, humic acid, and microorganisms. Herein,we describe a novel MALDI-TOF-MS method with a matrix of oxidized carbon nanotubes for analysis of low-mass compounds in environmental samples. A number of chemicals in the environment were qualitatively analyzed by the present method, and it was found that most of them, especially the highly polar chemicals, were measurable with high sensitivity. With the intrinsic ability to measure high-mass chemicals, this method can compensate for the current shortage of methods for environmental analysis for the measurement of highly polar or high-mass chemicals. For sample analysis, arsenic speciation in Chinese traditional medicines was qualified and diphenylolpropane in water samples was quantified. With the relatively high tolerance of the method to interfering molecules, a simple pretreatment or even no pretreatment could be employed before MS detection. Furthermore, this method can be employed in a high-throughput format.
Resumo:
An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with detection of UV absorbance and atmospheric pressure chemical ionization mass spectrometer (APCI/MS), respectively, and also analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes. Totally more than 188 components in P. corylifolia extract were detected with this integrated approach, and 12 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS. The obtained analytical results not only demonstrated the powerful resolution of integration IEC fractionation with reversed-phase liquid chromatography (RPLC)-APCI/MS and MALDI-TOF/MS for analysis of compounds in a complex sample, but also exhibited the superiority of APCI/MS and MALDI-TOF/MS for identification of low-mass compounds, such as for study of traditional Chinese medicines (TCMs) and metabolome. (c) 2005 Published by Elsevier B.V.
Resumo:
A hyphenated method for the isolation and identification of components in a traditional Chinese medicine of Honeysuckle was developed. Ion-exchange chromatography (IEC) was chosen for the fractionation of Honeysuckle extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further analyzed by reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer (RPLC-APCI/MS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes, respectively. It can be noted totally more than 117 components were detected by UV detector, APCI/MS and MALDI-TOF/MS in Honeysuckle extract except the, 145 components identified by MALDI-TOF/MS alone with this integrated approach, and 7 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS, respectively. The obtained analytical results not only indicated the approach of integration IEC fractionation with RPLC-APCI/MS and MALDI-TOF/MS is capable of analyzing complex samples, but also exhibited the potential power of the mass spectrometer in detection of low-mass compounds, such as traditional Chinese medicines (TCMs) and complex biological samples. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
High-performance liquid chromatography-tandem mass spectrometry has been used to identify isoflavone aglycones and glycosides in kudzu root. Fourteen isoflavones were detected. Among these, six were identified by comparison with authentic standards. Tentative identifications of the other isoflavones are based on UV spectra, mass spectra of protonated and deprotonated molecules, and MS-MS data. Several are reported for the first time in kudzu root. The bioactivity and bioavailability of isoflavone aglycones are usually greater than those of their glycosides. To improve the bioavailability of kudzu root isoflavones, crude beta-glycosidases prepared from microbes were used to hydrolyze the isoflavone glycosides. Several MS modes are combined not only to identify the isoflavones in kudzu root, but also to describe the biotransformation of kudzu root isoflavone glycosides. It is also proved that crude beta-glycosidases have high selectivity toward the O-glycosides of isoflavones.
Resumo:
A V:YAG single crystal was grown by the temperature gradient technique (TGT) with graphite-heating elements. The as-grown crystal has different colorations of light green and yellow brown in different parts. Distribution of vanadium in three samples with different colorations was determined by inductively coupled plasma-mass spectrometry. From the absorption spectrum of the yellow-brown part with peaks at 370, 820 and 1320nm, we can deduce that the reducing atmosphere of carbon diffused from the heating elements can increase the concentration of tetrahedral V3+ ions and induce F color centers. All three samples exhibited light-green color after annealing in vacuum or H-2 atmospheres. In the vacuum annealing process, the V3+ ions in tetrahedral positions were enhanced through two methods: one method is the exchanging of octahedral V3+ and tetrahedral Al3+ ions in neighboring sites under thermal excitation, the other is that F color centers were thoroughly eliminated and the escaped free electrons could be captured by V ions with higher valance states to further improve the concentration of tetrahedral V3+ ions. Besides the two mechanisms, the H-2 annealing process greatly improved the V-tetra(3+) ions through the reduction effect of H-2. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Snakehead fish (Ophiocephalus argus cantor), silver carp (Hypophthalmichthys molitrtix), crucian carp (Carassius carassius), and common carp (Cyprinus carpio) are four common freshwater fish species in China. In this study, the level of methylmercury (MeHg), total mercury (T-Hg), and total selenium (T-Se) in muscle samples of these four fish species from Ya-Er Lake, China, were analyzed using atomic fluorescence spectrometry coupled with high-performance liquid chromatography, and inductively coupled plasma mass spectrometry. The concentrations of MeHg in all the fish species were significantly correlated with those of T-Hg. Higher T-Hg and MeHg concentrations had accumulated in the snakehead fish, which is a strongly predatory fish, than in the other three species. The concentration ratios of MeHg and T-Hg in the muscles of these four fish species were almost equal. Conversely, there was negative correlation between the concentrations of T-Hg and T-Se, which implies that there is a competition between these two elements with respect to bioaccumulation. It is noteworthy that of all the muscle samples tested, the level of T-Hg exceeded the maximum allowable limit in fish [0.4 mg kg(-1) (w/w) recommended by the World Health Organization] in 38.46% of those of the silver carp, 18.18% of those of the crucian carp, and 100% of those of snakehead fish. These results show that the consumption of contaminated fish is a potential threat to human health and that necessary preventive measures to safeguard public health should be emphasized.
Resumo:
本论文分为两部分:1. 综述部分(第一章和第二章),评述了悬浮进样方式在电感耦合等离子体发射光谱法(ICP-OES)中的研究与应用;电感耦合等离子体质谱(ICP-MS)中碰撞/反应池技术研究的新进展。2. 实验部分(第三章至第九章),内容包括针对不同性质的样品悬浮液选择适当的稳定剂和悬浮雾化ICP-OES的校准方法研究;以混合碰撞/反应气体解决难度较大的高纯氧化钕中稀土杂质测定的干扰问题;以及浊点萃取-石墨炉原子吸收法测定环境样品中痕量镉、氢化物发生-原子荧光光谱法测定铅基合金中砷和植物样品中锗等实用性强的分析方法研究。 ICP的传统进样方式是将样品转化成水溶液形式,以溶液方式进样。然而大多数样品是以固态形式存在,许多样品相当难溶或难熔。采用直接固体进样方法对这些样品进行分析,是分析工作者追求的目标之一。悬浮液进样是一种固体直接进样方法,除了具有其它固体进样技术的优点外,其最大优点是可以像溶液雾化一样用标准水溶液校准。本研究针对实际分析工作中遇到的具体样品,对悬浮进样ICP-OES技术进行了比较深入的研究,成功解决了样品处理繁琐和样品难以处理等困难。对特殊地质样品和激光晶体材料(Nd:YAG)的悬浮进样分析进行了探索。主要工作为:①建立分析地质样品中主量和微量元素的方法,标准水溶液可以成功地用于校准。优点是可以同时对地质样品中的Si和其它元素进行分析,避免了传统分析时需分别处理样品的麻烦。②探索了分析铌钽矿中铌和钽的应用。由于铌和钽具有强抗化学腐蚀性,所以溶液进样分析时样品处理过程复杂。结果表明,以标准水溶液校准时,只要样品研磨时间延长至5 h,即可获得悬浮进样的满意的回收率。③研究了分析掺钕钇铝石榴石(Nd:YAG)中钕掺杂量的可行性。研究表明,加入适量聚丙烯酸作分散剂并调节pH为6,可以得到稳定悬浮液;以通用标准加入法(GSAM)校准可以得到满意的结果。 我国的稀土资源占世界的80%以上,高纯稀土氧化物是高科技领域中的重要材料。碰撞/反应池技术是目前四极杆ICP-MS消除干扰的先进技术,可以选择性地减少某些基体干扰,使背景和检测限得到显著的改进。本实验选择氧化钕(有7个同位素)作为研究对象,采用碰撞/反应池技术重点解决四极杆ICP-MS方法对高纯Nd2O3中稀土杂质进行测定时,基体Nd对Tb、Dy和Ho严重的氧化物或氢氧化物干扰难题。研究结果如下:①在四极杆高分辨率模式下,可以消除Nd对Pr的相邻峰的拖尾干扰;②采用碰撞/反应池技术,设计了10% O2-10% Ar-80% He混合气体作为碰撞/反应气,将Tb、Dy和Ho分别转化为相应的氧化物离子进行测定,成功地消除了基体Nd对Ho的干扰;Nd对Tb和Dy造成干扰的表观浓度显著降低。本方法可直接测定纯度为6N的高纯Nd2O3中的Ho;对纯度为6N的高纯Nd2O3中的Tb和Dy进行扣除,可以分析纯度达5N的高纯Nd2O3中的Tb和Dy。与文献报道的其它消除基体Nd干扰的方法相比较,此方法能够对纯度更高的Nd2O3进行直接分析,且操作简便。此方法也可进一步拓宽,有望解决其它轻稀土氧化物对中重稀土检测的质谱干扰问题。 论文的7~9章的工作包括:浊点萃取-GFAAS测定环境样品中痕量镉、HG-AFS分析铅基合金中砷和植物样品中锗的研究。针对实际分析工作中的具体困难,以上工作分别解决了分析元素含量低、测定干扰严重及样品处理的问题,建立了实用性强、准确度高的分析方法,具有实际应用价值。
Resumo:
Nonviral vectors are safer than viral systems for gene therapy applications. However, the limited efficacy always prevents their being widely used in clinical practice. Aside from searching new gene nonviral vectors, many researchers focus on finding out new substances to improve the transfection efficiency of existent vectors. In this work, we found a transfection enhancer, nocodazole (NCZ), for dimethyldioctadecylammonium (DODAB, a cationic lipid) bilayer coated gold nanoparticles (AuNPs) mediated gene delivery. It was found that NCZ produces 3-fold transfection enhancement to HEK 293T cells assessed by flow cytometry (FCM). The result was further confirmed by luciferase assay, in which NCZ induced more than 5 times improvement in transfection efficiency after 48 h of transfection. The results from the inductively coupled plasma mass spectrometry (ICP-MS) and FCM showed that NCZ did not affect the internalization of DODAB-AuNPs/DNA complexes. The trafficking of the complexes by transmission electron microscopy (TEM) indicated that the interrupted transportation of the complexes to the lysosomes contributed greatly to the transfection enhancement.
Resumo:
A method was developed for the determination of trace and ultratrace amounts of REE. Cd. In. Tl. Th. Nb, Ta. Zr and Hf in soils and sediments. With NaOH-Na2O2 as the flux. Ti(OH)(4)-Fe(OH)(3) co-precipitation as the preconcentration technique and inductively coupled plasma mass spectrometry (ICP-MS) for measurement, the whole procedure was concise and suitable for batch analysis of multi-element solutions. An investigation was carried out of the Ti(OH)(4)-Fe(OH)(3) co-precipitation system, and the results obtained showed that the natural situation of Ti tightly coexisting with Nb. Ta, Zr and Hf in geological samples plays a very important role in the complete co-precipitation of the four elements. The accuracy of this procedure was established using six Chinese soil and sediment certified reference materials (GSS and GSD). and the relative errors between the found and certified values were mostly below 10%.