162 resultados para LD pump


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Doubled femtosecond laser pulses in-line are needed in the collinear pump-probe technique, collinear second harmonic generation frequency-resolved optical gating (SHG FROG) and the spectral phase interferometry for direct electric-field reconstruction (SPIDER), etc. Normally, it is generated by using a Michelson's structure. In this paper, we proposed a novel structure with two-layered reflective Dammann gratings and the reflective mirrors to generate doubled femtosecond laser pulses in line without transmission optical elements. Angular dispersion and spectral spatial walk-off are both compensated. In addition, this structure can also compress the positive chirped pulse, which cannot be realized with a Michelson's structure. By adopting triangular grating and blazed gratings, the efficiency of the system would in principle be increased as the Michelson's scheme. Experiments demonstrated that this method should be an alternative approach for generation of the double compressed pulses of femtosecond laser for practical applications. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We found reversible dark-center diffraction of the transmitted probe beam passing through the chromium film. which is induced by the pump femtosecond laser. The dark-center diffraction of I he transmitted probe beam appears and disappears with and without the pump beam. A view of diffractive optics with binary phase plate is put forward, which explains the reversible dark-center diffractive optical phenomenon. The pre-ablated hole on the metal film can be regarded as a uniform light filed without phase modulation, the Surrounding Circular part around the pre-ablated hole can be regarded as "phase modulated". Therefore, this diffraction optic view might be helpful for us to understand the phase change of the metal film introduced by the femtosecond laser pulse. (C) 2008 Elsevier B.V, All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As there exist some problems with the previous laser diode (LD) real-time microvibration measurement interferometers, such as low accuracy, correction before every use, etc., in this paper, we propose a new technique to realize the real-time microvibration measurement by using the LD sinusoidal phase-modulating interferometer, analyze the measurement theory and error, and simulate the measurement accuracy. This interferometer utilizes a circuit to process the interference signal in order to obtain the vibration frequency and amplitude of the detective signal, and a computer is not necessary in it. The influence of the varying light intensity and light path difference on the measurement result can be eliminated. This technique is real-time, convenient, fast, and can enhance the measurement accuracy too. Experiments show that the repeatable measurement accuracy is less than 3.37 nm, and this interferometer can be applied to real-time microvibration measurement of the MEMS. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

基于对称双侧激光二极管(LD)抽运Nd:GGG(掺钕钆镓石榴石)激光晶体板条,从热传导基本方程出发,以废热等效于内热源模型为前提,利用有限元分析软件ANSYS对Nd:GGG板条在热容工作下的瞬态温度场及应力场进行了数值模拟,分析了在不同边界条件下温度和应力随时间和空间的变化特性及其热致变形。计算结果表明:在激光发射阶段,边界非绝热使得板条在垂直光轴方向产生温度梯度,由此产生的折射率梯度和应力梯度导致距离光轴最远的板条边缘和光轴处产生约0.2μm的变形量。同时模拟了冷却阶段空气对流冷却、水循环冷却及喷雾冷却

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在用半导体激光器抽运的单包层掺Yb调Q光纤激光器中观察到了清晰稳定的自锁模脉冲序列。脉冲包络形状为调Q脉冲。每个锁模脉冲的幅值由其在调Q脉冲中的相应位置决定。经过分析,认为自相位调制是调Q光纤激光器中产生锁模的主要原因。自相位调制的存在使得光脉冲的频谱被展宽,当这种展宽和腔的模式间隔相差不多时,腔内的模式便能相互作用,直到它们之间产生一个固定的相位关系。也即形成锁模。在此基础上。去掉声光晶体,并用两个光栅作为腔镜,实现了全光纤法布里-珀罗(F-P)腔锁模光纤激光器。改变腔结构,分别采用光栅和光纤反射圈作为

Relevância:

10.00% 10.00%

Publicador:

Resumo:

从放大器速率方程出发,分析了掺镱双包层光纤放大器的放大特性。模拟计算了无信号输入时放大器上能级粒子数、泵浦功率和放大自发辐射(ASE)在放大器中的稳态分布。分析了前向和后向泵浦时,高功率高斯脉冲放大时的脉冲波形畸变、上能级粒子数的时间特性、放大器存储能量和脉冲能量演化等动态特性。讨论了掺镱双包层光纤放大器输出脉冲能量随不同输入脉冲峰值功率和泵浦功率的关系。该模型和结论对高功率脉冲放大器的设计和优化具有一定的理论指导意义。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stable single-frequency and single-polarization distributed-feedback (DFB) fiber laser was realized by giving a pressure on the phase shift region of the fiber grating. The output wavelength of the DFB fiber laser is 1053 nm. When the pump power of 980 nm laser diode is 100 and 254 mW, the output power can reach 8.3 and 37.1 mW and the polarization extinction ratio was 26 and 20 dB, respectively. After chopped by Acousto-optic modulator (0.3 Hz), the pulse peak value variance is 4.65%(peak to peak) and 1.098% (RMS) for 31 min. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

由于a轴切割Nd∶YVO4晶体的非对称性,使得激光二极管(LD)端面抽运Nd∶YVO4固体激光器不同于Nd∶YAG激光器,输出的激光经常产生非对称结果。用有限元法分析激光二极管端面抽运a轴切割Nd∶YVO4固体激光器的晶体热效应,包括温度分布、内部应力和产生的形变。分析结果表明端面抽运a轴切割Nd∶YVO4晶体产生了椭球热透镜效应。从结构方面和抽运方面提出了热透镜非对称性的平衡方法,实验验证了方法的可行性。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

从掺镱(Yb)光纤放大器的功率传输方程出发,利用有限差分法对小模场面积(SMA)和大模场面积(LMA)掺镱双包层光纤放大器的放大特性进行了分析比较。采用模场直径(MFD)6.5 μm和20 μm的双包层掺镱光纤作为放大器增益介质进行窄线宽连续信号的放大,在915 nm激光抽运下模拟计算了大、小模场面积输出功率随输入信号功率、抽运光功率和光纤长度的变化特性,特别是对于大模场面积光纤放大器,最优光纤长度的选择至关重要;讨论了模场直径不同时的最优抽运功率和光纤长度的选择,得出4 m光纤放大时的临界抽运功率为4

Relevância:

10.00% 10.00%

Publicador:

Resumo:

采用遮挡法引入相移制作了掺Yb相移光纤光栅(PS-FBG)。在制作光栅的过程中,将其作为激光器的谐振腔,通过监测激光器的输出功率来确定相移大小。当激光器的输出功率开始下降时,停止曝光,此时引入的相移为π/2。为了使光栅的特性尽快稳定下来需要对光栅进行退火,这将导致引入的相移小于π/2。为了弥补退火过程中引起的相移降低,需要对退火后的光栅进行二次曝光,以使光栅的相移恢复π/2。利用该方法制作了一只光纤光栅激光器。当抽运功率为100 mW时,获得了25 mW的输出功率,信噪比(SNR)为60 dB。在1 h内

Relevância:

10.00% 10.00%

Publicador:

Resumo:

设计并实现了一种放大纳秒激光脉冲的高稳定的激光二极管(LD)抽运Nd∶YLF再生放大器。为了获得高稳定的输出,再生放大器工作在饱和状态。此时,再生放大器输出稳定性最好,而且注入激光脉冲能量波动引起的输出激光脉冲波动被抑制。由于增益饱和效应,再生放大器输出脉冲出现时域波形失真,附加后缀脉冲能够减弱时域波形失真。放大器工作波长1053nm,工作频率1Hz。输入240pJ的3ns方波激光脉冲,输出激光脉冲能量4.2mJ,总增益大于107,不稳定度小于1%(均方根),方波扭曲1.33。为3ns方波激光脉冲引入其本身幅度0.75倍的后缀脉冲,输出激光脉冲方波扭曲由1.33降至1.17。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Incorporating the shielded method and post-processing method, a 75 mW single frequency Yb-doped DFB fiber laser was obtained with a 250 mW laser diode pump source at 978 nm. The threshold of the laser is 2 mW. The laser is single-polarization operation and the output power fluctuation is less than 0.2 mW in one hour when the pump power is 250 mW.