373 resultados para CASTE DETERMINATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the sensitive determination of amino acids and peptides using the tagging reagent 2-(9-carbazole)-ethyl chloroformate (CEOC) with fluorescence (FL) detection has been developed. Identification of derivatives was carried out by liquid chromotography mass spectrometry. The chromophore in the 2-(9-fluorenyl)-ethyl chloroformate (FMOC) reagent was replaced by carbazole, which resulted in a sensitive fluorescence lerivatizing agent CEOC. CEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. Studies on derivatization demonstrate excellent derivative yields over the pH range 8.8-10.0. Maximal yields close to 100% are observed with three- to fourfold molar reagent excess. Derivatives exhibit strong fluorescence and allow direct injection of the reaction mixture with no significant disturbance from the major fluorescent reagent degradation by-products, such as 2(9-carbazole)-ethanol and bis-(2-(9-carbazole)-ethyl) carbonate. In addition, the detection responses for CEOC derivatives are compared to those obtained with FMOC. The ratios AC(CEOC)/AC(FMOC) = 1.00-1.82 for fluorescence (FL) response and AC'(CEOC)/AC'(FMOC) = 1.00-1.21 for ultraviolet (UV) response are observed (here, AC and AC' are, respectively, FL and UV F response). Separation of the derivatized peptides and amino acids has been optimized on a Hypersil BDS C18 column. Excellent linear responses are observed. This method was used successfully to analyze protein hydrolysates from wool and from direct-derivatized beer. (C) 2003 Elsevier Science (USA). All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the method for the derivatization of carbohydrates with 1-phenyl-3-methyl-5-pyrazolone (PMP) was simplified. One-third of the derivatization time was saved. Five monosaccharide derivatives have been well separated by MEKC and HPLC under optimized conditions. Good reproducibility could be obtained with relative standard deviation (RSD) values of the migration times within 5.0 and 2.3%, respectively. Furthermore, the developed methods have been successfully applied to the analysis of carbohydrates in Aloe powder and food. These methods are quite useful for routine analysis of monosaccharides and oligosaccharides in real samples. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determination of arsenic species by large-volume field amplified stacking injection-capillary zone electrophoresis (LV-FASI-CZE) is reported in this paper. Whole column injection was employed. The optimum buffer pH for the separation of weak acids was discussed. It was found that the optimum buffer to analyze the stacked arsenate (As(V)), monomethylarsonate (MMA), and dimethylarsinate (DMA) was 25 mm phosphate at pH 6.5. However, the optimum buffer to analyze the concentrated arsenite (As(III)) was 20 mm phosphate - 10 mm borate at pH 9.28. The limits of detection of the method developed were 0.026 mg/L for As(III), 0.023 mg/L for As(V), 0.043 mg/L for MMA, and 0.018 mg/L for DMA. An enrichment factor of 34-100 for several arsenic species was obtained. In the end, this method was applied to determine the arsenic concentration in the environmental reference materials to show the usefulness of the method developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for the determination of N-acetylneuraminic acid (NANA) and N-glycolylneuraminic acid (NGNA) has been developed using high-performance capillary electrophoresis with UV detection at 195 nm, without pre or post-column derivatisation. The acids were separated in a 50-cm, fused-silica capillary (50 mu m i.d, 45.5-cm effective length) with Na2B4O7-Na2HPO4 buffer. The detection limit for NANA is a concentration of 9.6 x 10(-6) M or, in terms of mass: 3.879 x 10(-14) mol (39 fmol). This method is applicable to determination of NANA in normal human serum. The results were also compared with those of the colorimetrie method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0×10-6-1.0×10-1 M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3 - 5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chelates formed between the heavy metal ion Pb(II) and the reagents 8-hydroxy-5-quinolinesulphonic acid, 8-hydroxy-7-quinolinesulphonic acid and 8-hydroxy-7-iodo-5-quinolinesulphonic acid exhibit strong room temperature phosphorescence (RTP) if retained on the surface of anion exchange resin beads. Based on the on-line formation, in a flow-injection system, of such RTP lead chelates and their transient immobilization on an anion exchange resin, three flow-through optosensing systems are investigated for lead in sea water. Optimum experimental conditions and the analytical performance characteristics of the three optosensors are discussed. Relative standard deviations (RSDs) of the order of 3% are typical at 100 ng ml−1 Pb(II) and the active sensing phases can easily be regenerated by passing 500 μl of 6 M hydrochloric acid. A lead(II) detection limit of 0.1 ng ml−1 (3×background SD, for 2 ml sample injection volumes) was achieved for the optosensor based on 8-hydroxy-7-quinolinesulphonic acid. Possible interferences present in sea water, including cations and anions which could affect the sensor response, are discussed in detail. Finally, the selected RTP flow-through optical sensor has been successfully tested for the determination of lead in sea water at a few ng ml−1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A poly(vinyl chloride)(PVC)-based membrane of 15-crown-5 exhibits a good response for lead(II) ions over a wide concentration range. The response time of the sensor is 30 s and the membrane can be used for more than four months without observing any divergence. The selectivity of the sensor is comparable with those reported for other such electrodes. It was possible to determine lead in polluted waters using this electrode assembly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automated and semi-intelligent voltammetric system is described for trace metal analysis. The system consists of a voltammeter interfaced with a personal computer, a sample changer, 2 peristaltic pumps, a motor burette and a hanging mercury drop electrode. The system carries out fully automatically approximately 5 metal determinations per hour (including at least 3 repetitive scans and calibration by standard addition) at trace levels encountered in clean sea water. The computer program decides what level of standard addition to use and evaluates the data prior to switching to the next sample. Alternatively, the system can be used to carry out complexing ligand titration with copper whilst recording the labile copper concentration; in this mode up to 8 full titrations are carried out per day. Depth profiles for chromium speciation in the Mediterranean Sea and a profile for copper complexing ligand concentrations in the North Atlantic Ocean measured on board-ship with the system are presented. The chromium speciation was determined using a new method to differentiate between Cr(III) and Cr(VI) utilizing adsorption of Cr(III) on silica particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variety of short-lived, reactive chemical species (i.e. free radicals and excited state species) are known to be photochemically produced in natural waters. Some of these transients may strongly affect chemical and biological processes, and they have been implicated in the degradation of organic pollutants and natural organic compounds in aqueous environments. Previous studies demonstrated that the highly reactive hydroxyl radical (OH) is photochemically formed in seawater. However, the quantitative importance of this key species in the sea has not been previously studied because of past analytical limitations. By using a highly sensitive probe based on α-H atom abstraction from methanol, we were able to measure production rates and steady-state concentrations of photochemically produced OH radicals in coastal and open ocean seawater and freshwaters. The validity of the method was tested by intercalibrating with an independent, OH-specific reaction, hydroxylation of benzoic acid, and also by competition kinetics experiments. Our OH production rates and steady-state concentrations for freshwaters are in excellent agreement with those measured by previous investigators for similar waters. In contrast, for seawater, the values we measured are 1–3 orders of magnitude higher than previously predicted by models, indicating that there is a major unknown photochemical OH source (s) in seawater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with determining points of zero charge of natural and Na+-saturated mineral kaolinites using two methods: (1) acid-base potentiometric titration was employed to obtain the adsorption of H+ and OH- on amphoteric surfaces in solutions of varying ionic strengths in order to determinate graphically the point of zero net proton charge (PZNPC) defined equally as point of zero salt effect (PZSE); (2) mass titration curve at different electrolyte concentrations in order to estimate PZNPCs by interpolation and to compare with those determined by potentiometric titrations. The two methods involved points of zero charge approximately similar for the two kaolinites between 6.5-7.8, comparable to those reported previously and were in the range expected for these clay minerals. The comparison of potentiometric surface titration curves obtained at 25 °C and those published in the literature reveals significant discrepancies both in the shape and in the pH of PZNPCs values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

zero point of charge of freshly precipitated cu(oh)2 has been determined to lie at pH 7.7 by means of microclectrophoresis technique. Day aged hydroxide shows an acid zpc shift to pH 7.3. these experimental values approximate the equivalence points of cu+ and oh_ ,which can be estimated from the solubility diagram constructed fo gu(oh)2 and cuo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

the salt ritration metod was evaluated as a method to determine zpc in comparison with the potentiometric titration method for 26 soil with variable charge clays,i.e.,Oxisols and Ultisols from Thailand and Andisols from Japan. In addition to the determination of ST-pH0 as the zero point of charge, a calculation procedure was adopted here in order to acquire more information from the titration curve . fuithermore, for the purpose of cross-checking of zpc determined by the pt method, the st procedure was successively applied to the samples analyzed by the pt method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time, we report a sensitive and selective method to detect Cu2+ based on the electrochemiluminescence quenching of CdTe quantum dots (QDs) in aqueous solution. The mercaptosuccinic acid (MSA) protected CdTe QDs were prepared and characterized with UV, fluorescence and ECL. The anodic ECL quenching mechanism was attributed to the fact that MSA capping was removed from the surface of the CdTe QDs and preferentially bound with Cu2+. The displacement of MSA capping layer created imperfections on the CdTe QDs surface, and eventually led to the ECL quenching.