31 resultados para urinary incontinence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Yunnan snub-nosed monkey (Rhinopithecus bieti) is one of the most endangered species in the world, and it is endemic to China. According to our knowledge, there was no information on reproduction for this species. The present study was designed to und

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the occupational exposure levels to polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polybrominated diphenyl ethers (PBDEs), and polychlorinated biphenyls (PCBs), indoor dust (n = 3) in workshops and hair samples from male workers (n = 64) were collected at two electrical and electronic equipment waste (E-waste) dismantling factories located in the LQ area in east China in July 11-13, 2006. Pre- and postworkshift urines (64 of each) were also collected from the workers to study oxidative damage to DNA using 8-hydroxy-2'-deoxyguanosine (8-OHdG) as a biomarker. The concentrations of PCDD/Fs, PCDD/F-WHO-TEQs, PBDEs, PCBs and PCB-WHO-TEQs were (50.0 +/- 8.1) x 10(3), 724.1 +/- 249.6, (27.5 +/- 5.8) x 10(6), (1.6 +/- 0.4) x 10(9), (26.2 +/- 3.0) x 10(3) pg/g dry weight (dw) in dust, and (2.6 +/- 0.6) x 10(3), 42.4 +/- 9.3, (870.8 +/- 205.4) x 10(3), (1.6 +/- 0.2) x 10(6), 41.5 +/- 5.5 pg/g dw in hair, respectively. The homologue and congener profiles in the samples demonstrated that high concentrations of PCDD/Fs, PBDEs, and PCBs were originated from open burning of E-waste. The 8-OHdG levels were detected at 6.40 +/- 1.64 mu mol/mol creatinine in preworkshift urines. However, the levels significantly increased to 24.55 +/- 5.96 mu mol/mol creatinine in postworkshift urines (p < 0.05). Then, it is concluded that there is a high cancer risk originated from oxidative stress indicated by the elevated 8-OHdG levels in the E-waste dismantling workers exposed to high concentrations of PCDD/Fs, PBDEs, and PCBs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

8-hydroxy-2'-deoxyguanosine (8OHdG) has been widely used as a biomarker of oxidative DNA damage in both animal models and human studies. To evaluate the effect of cigarette smoking on oxidative stress, we studied the levels of urinary 8OHdG from smokers and non-smokers and investigated the association with cigarette smoking. The urinary 8OHdG concentrations were determinated by capillary electrophoresis with end-column amprometric detection (CE-AD) after a single-step solid phase extraction (SPE), and then quantitatively expressed as a function of creatinine excretion. To increase the concentration sensitivity, a dynamic pH junction was used and the focusing effect was obvious when using 30 mM phosphate (pH 6.50) as sample matrix. The limit of detection is 4.3 nM (signal-to-noise ratio S/N = 3). The relative standard deviation (R.S.D.) was 1.1% for peak current, and 2.3% for migration time. Based on the selected CE-AD method, it was found that the mean value of urinary 8OHdG levels in the smokers significantly higher than that in non-smokers (31.4 +/- 18.9 nM versus 14.4 +/- 7.6 nM, P = 0.0004; 23.5 +/- 21.3 mug g(-1) creatinine versus 12.6 +/- 13.2 mug g(-1) creatinine, P = 0.028). (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased oxidative stress induced by hyperglycemia may contribute to the pathogenesis of diabetic complications. Urinary 8-hydroxydeoxyguanosine (8-OHdG) has been reported to serve as a sensitive biomarker of oxidative DNA damage and also of oxidative stress. This article studied oxidative DNA damage in patients with diabetic nephropathy and in healthy control subjects by urinary 8-OHdG evaluations. Contents of 8-OHdG in urine were analyzed by capillary electrophoresis with end-column amperometric detection (CE-AD) after a single-step solid-phase extraction (SPE). Levels of urinary 8-OHdG in diabetic nephropathy patients with macroalbuminuria was significant higher than in control subjects (5.72 +/- 6.89 mumol/mol creatinine versus 2.33 +/- 2.83 mumol/mol creatinine, P = 0.018). A significant difference of 24 h urinary 8-OHdG excretions exists between the patients with macroalbuminuria and the patients with nonnoalbuminuria (19.2 +/- 16.8 mug/24 h versus 8.1 +/- 1.7 mug/24 h, P = 0.015). There was a positive correlation between urinary excretion of 8-OHdG and glycosylated hemoglobin (HbA(1)c) (r = 0.287, P = 0.022). A weak correlation exists between the levels of 8-OHdG and triglyceride (r = 0.230, P = 0.074). However, the urinary 8-OHdG contents are not correlated with blood pressure and total cholesterol. The increased excretion of urinary 8-OHdG is seen as indicating an increased systemic level of oxidative DNA damage in diabetic nephropathy patients. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modified nucleosides, formed post-transcriptionally in RNA by a number of modification enzymes, are excreted in abnormal levels in the urine of patients with malignant tumors. To test their usefulness as tumor markers, and to compare them with the conventional tumor markers, a reversed-phase high-performance liquid chromatographic (RP-HPLC) method and a factor analysis method have been used to study the excretion pattern of nucleosides of breast cancer patients. A clear cut differentiation of the breast cancer group and the healthy individuals in two clusters without overlapping was obtained. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper gives a capillary electrophoretic method for the separation of 15 urinary normal and modified nucleosides from cancer patients in less than 40 min. A 500 mmx50 mu m uncoated capillary column (437.5 mm to window) was used. The effects of the voltage and the sodium dodecyl sulfate (SDS) concentration in the buffer on the separation were studied. With reproducibilities of migration times better than 1.2% (R.S.D.) and determined concentrations better than 5-25%, depending on the concentrations of nucleosides in the urine, the analytical characteristics of the method were food. Using this developed method, the concentrations of 13 normal and modified nucleosides, extracted on a phenyl boronic acid affinity chromatography column, in 25 urines from patients of 14 kinds of cancer were determined. The levels (nmol/mol creatinine) of modified nucleosides in urines from cancer patients were increased as compared with those in normal urines. (C) 1998 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nucleosides in human urine and serum have frequently been studied as a possible biomedical marker for cancer, acquired immune deficiency syndrome (AIDS) and the whole-body turnover of RNAs. Fifteen normal and modified nucleosides were determined in 69 urine and 42 serum samples using high-performance liquid chromatography (HPLC). Artificial neural networks have been used as a powerful pattern recognition tool to distinguish cancer patients from healthy persons. The recognition rate for the training set reached 100%. In the validating set, 95.8 and 92.9% of people were correctly classified into cancer patients and healthy persons when urine and serum were used as the sample for measuring the nucleosides. The results show that the artificial neural network technique is better than principal component analysis for the classification of healthy persons and cancer patients based on nucleoside data. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A feeding trial A as conducted at the farm of Qinghai Academy of Animal and Veterinary Science, Xining, China during 1996 - 1997 with three dry yak cows (initial body weight 163 - 197 kg, age 5 - 6 years) by using 3 x 3 Latin Square Design to determine the effect of levels of feed intake on digestion, nitrogen balance and purine derivative excretion in urine of yak cows. The animals were fed oat hay (nitrogen 13.5 g/kg dry matter (DM), metabolisable energy 8.3 MJ/kg DM), i.e., 0.3, 0.6 and 0.9 of voluntary intake (VI). Each intake treatment lasted for 17 days and the samples (feeds, faeces and urine) were collected during last 7 days of each period. The results indicate that digestibility of dietary DM, OM, NDF and ash declined when intake levels increased from 0.3 to 0.9 VI [DM, from 66.1% to 59.1% (P < 0.05); OM, from 68.1% to 59.9% (P < 0.05); NDF, from 62.1% to 54.3% (P < 0.05); and ash, from 33.9% to 11.8% (P < 0.05)]. Around 0.10 g N/kg W-0.75 was deficient daily in yak cows at 0.3 VI, and positive N balances were observed at 0.6 and 0.9 VI. Intake levels significantly (P < 0.05) affected total PD excretion in yak urine. The proportion of allantoin increased (P < 0.05) and uric acid decreased (P < 0.05) as intake level of feed increased. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary 8-hydroxydeoxyguanosine (80HdG) has been considered as an excellent marker of individuals at high risk of developing cancer. Until now, urinary 80HdG has largely been measured by high-performance liquid chromatography with electrochemical detection. A new method for the analysis of urinary 80HdG by high-performance capillary electrophoresis has been developed and optimized in our laboratory. A single step solid-phase extraction procedure was optimized and used for extracting 80HdG from human urine. Separations were performed in an uncoated silica capillary (50 cm x 50 tm i.d.) using a P/ACE MDQ system with UV detection. The separation of 80HdG from interfering urinary matrix components is optimized with regard to pH, applied voltage, pressure injection time and concentration of SDS in running buffer. The detection limit of this method is 0.4 mug/ml, the linear range is 0.8-500 mug/ml, the correlation coefficients levels is better than 0.999. The developed method is simple, fast and good reproducibility, furthermore, it requires a very small injection volumes and low costs of analysis, which makes it possible to provide a new noninvasive assay for an indirect measurement of oxidative DNA damage.