73 resultados para Radioactive installation
Resumo:
We briefly introduce the current status and progress in the field of radioactive ion beam physics and the study of super-heavy nuclei. Some important problems and research directions are outlined, such as the sub-barrier fusion reaction, the direct reaction at Fermi energy and high energies, the property of nuclei at drip-lines, new magic numbers and new collective motion modes for unstable nuclei and the synthesis and study of the super-heavy nuclei.
Enhanced biological effect induced by a radioactive C-9-ion beam at the depths around its Bragg peak
Resumo:
To explore the potential of double irradiation source, radioactive C-9-ion beam, in tumor therapy, a comparative study oil the surviving effect of human salivary gland cells at different penetration depths between C-9 and C-12-ion beams has been carried out. The 9C-ion C beam, especially at the distal side of the beam came out more efficient in cell killing at the depths around its Bragg peak than the 12 Bragg peak. Compared to the C-12 beam, an increase in RBE by a factor of up to 2.13 has been observed at the depths distal to the Bragg peak of the 9C beam. The 9C beam showed an enhanced biological effect at the penetration depths around its Bragg peak, corresponding to the stopping region of the incident C-9-ions and where the delayed low-energy particles were emitted. Further analysis revealed that cell lethality by the emitted particles from the stopping C-9-ions is responsible for the excessive biological effect at the penetration depths around the Bragg peak of the C-9 beam.
Resumo:
The measurement of void fraction is of importance to the oil industry and chemical industry. In this article, the principle and mathematical method of determining the void fraction of horizontal gas-liquid flow by using a single-energy gamma-ray system is described. The gamma-ray source is the radioactive isotope of Am-241 with gamma-ray energy of 59.5 keV. The time-averaged value of the void fraction in a 50.0-mm i.d. transparent horizontal pipeline is measured under various combinations of the liquid flow and gas flow. It is found that increasing the gas flow rate at a fixed liquid flow rate would increase the void fraction. Test data are compared with the predictions of the correlations and a good agreement is found. The result shows that the designed gamma-ray system can be used for measuring the void fraction in a horizontal gas-liquid two-phase flow with high accuracy.
Resumo:
Keller proposed that a building, a mechanical installation or a body wrapped bya layer of foam plastics may be an efficient means for protection from damage ofblast wave. However, the practical effect was beyond expectation. For example, agunner wearing the foam plastics-padded waistcoat was injured more seriously by theblast wave from a muzzle. Monti took the foam plastics as homogeneous two-phasemedium and analyzed it with the theory of dusty flow. The obtained results showthat the peak pressure behind the reflected shock wave from rigid wall with foamcoat exceeds obviously that without foam coat under the same condition. Gel'fand,Patz and Weaver made experimental observations by means of shock tubes and veri-
Resumo:
共光路外差干涉仪具有很高的分辨率.但因为安装、调试误差会产生非线性误差.影响系统的测量精度。着重分析了在共光路外差干涉仪中由激光光源的椭圆偏振化和沃拉斯顿棱镜的安装方位角误差同时存在的情况下,引起的频率混叠综合误差的大小及变化规律。结果发现其造成的非线性误差可达2.2nm,同时还发现两者造成的误差在某些情况下存在一定程度的相互抵消作用。讨论了提高测量系统精度的有效措施,对正确设计和调试激光外差测试系统、提高测量系统精度具有重要意义。