131 resultados para Matrix Transform Method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

采用一种非接触的光学方法傅立叶变换莫尔法(Fourier transform method),结合数字图像处理技术,对微幅振荡的水表面波的振幅进行测量.它是对全场中每一个像素点进行测量,比接触测量法具有更高的灵敏度.它为微幅水表面波振幅的测量提供了一种手段.通过将计算机生成的周期性光栅图像经投影机直接投影到被测物体的参考平面,经CCD摄像头、图像板捕捉存储形成数字化的光栅图像,利用傅立叶变换莫尔法处理光栅图像,从而获得包含有水表面波的振幅的相位信息,再经适当的几何变换获得振幅信息.我们在垂直振荡装置上进行了不同激励频率和不同振幅的表面波的振幅测量.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To improve the accuracy of measured gain spectra, which is usually limited by the resolution of the optical spectrum analyzer (OSA), a deconvolution process based on the measured spectrum of a narrow linewidth semiconductor laser is applied in the Fourier transform method. The numerical simulation shows that practical gain spectra can be resumed by the Fourier transform method with the deconvolution process. Taking the OSA resolution to be 0.06, 0.1, and 0.2 nm, the gain-reflectivity product spectra with the difference of about 2% are obtained for a 1550-nm semiconductor laser with the cavity length of 720 pm. The spectra obtained by the Fourier transform method without the deconvolution process and the Hakki-Paoli method are presented and compared. The simulation also shows that the Fourier transform method has less sensitivity to noise than the Hakki-Paoli method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The application of digital holographic interferometry on the quantitative measurement of the domain inversion in a RuO2: LiNbO3 crystal wafer is presented. The recorded holograms are reconstructed by the angular spectrum method. From the reconstructed phase distribution we can clearly observe the boundary between the inverted and un-inverted domain regions. Comparisons with the results reconstructed by use of the Fresnel transform method are given. Factors that influence the measurement include the spectrum filter size and the spectrum movement are discussed. The spectrum filter size has an effect on the measurement of the details. Although the spectrum movement affects every single reconstructed image, it has no influence on the final measurement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, we propose a deterministic column-based matrix decomposition method. Conventional column-based matrix decomposition (CX) computes the columns by randomly sampling columns of the data matrix. Instead, the newly proposed method (termed as CX_D) selects columns in a deterministic manner, which well approximates singular value decomposition. The experimental results well demonstrate the power and the advantages of the proposed method upon three real-world data sets.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

采用一种非接触的光学方法——傅立叶变换莫尔法(Fourier transform method),结合数字图像处理技术,对微幅振荡的水表面波的振幅进行测量。它是对全场中每一个像素点进行测量,比接触测量法具有更高的灵敏度。它为微幅水表面波振幅的测量提供了一种手段。通过将计算机生成的周期性光栅图像经投影机直接投影到被测物体的参考平面,经CCD摄像头、图像板捕捉存储形成数字化的光栅图像,利用傅立叶变换莫尔法处理光栅图像,从而获得包含有水表面波的振幅的相位信息,再经适当的几何变换获得振幅信息。我们在生趣振荡装置上进行了不同激励频率和不同振幅的表面波的振幅测量。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A biosensor based on imaging ellipsometry (BIE) has been developed and validated in 169 patients for detecting five markers of hepatitis B virus (HBV) infection. The methodology has been established to pave the way for clinical diagnosis, including ligand screening, determination of the sensitivity, set-up of cut-off values (CoVs) and comparison with other clinical methods. A matrix assay method was established for ligand screening. The CoVs of HBV markers were derived with the help of receiver operating characteristic curves. Enzyme-linked immunosorbent assay (ELISA) was the reference method. Ligands with high bioactivity were selected and sensitivities of 1 ng/mL and 1 IU/mL for hepatitis B surface antigen (HBsAg) and surface antibody (anti-HBs) were obtained respectively. The CoVs of HBsAg, anti-HBs, hepatitis B e antigen, hepatitis B e antibody and core antibody were as follows: 15%, 18%, 15%, 20% and 15%, respectively, which were the percentages over the values of corresponding ligand controls. BIE can simultaneously detect up to five markers within 1 h with results in acceptable agreement with ELISA, and thus shows a potential for diagnosing hepatitis B with high throughput.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

利用两束超连续光干涉得到的信号,测量了透镜焦点附近飞秒激光脉冲的古依(Gouy)相移。根据得到的光谱干涉信号,利用傅里叶变换得到相对相位值。激光光束在聚焦透镜后的束腰半径可以由成像方法测得。根据测量得到的激光光束束腰半径,用非线性拟合的方法得到了古依相移曲线,拟合曲线与实验结果符合得非常好。给出了古依相位在焦点前后1 mm区域内的移动量。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We quantitatively study the domain inversion in a RuO2:LiNbO3 crystal wafer by the digital holographic interferometry. The crystal wafer is placed into one arm of a Mach-Zehnder-type interferometer to record a series of holograms. Making use of the angular spectrum backward propagation algorithm, we reconstruct the optical wave field in the crystal plane. The extracted phase difference from the reconstructed optical wave field is a well linear function of the applied external voltage. We deduce that the linear electro-optic coefficient of the detected RuO2:LiNbO3 crystal sample is 9.1x10(-12) m/V. An unexpected phase contrast at the antiparallel domain wall is observed and the influence of the applied external voltage on it is studied in detail. Also the built-in internal field is quantitatively measured as 0.72 kV/mm. (c) 2006 American Institute of Physics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Talbot effect of a grating with different kinds of flaws is analyzed with the finite-difference time-domain (FDTD) method. The FDTD method can show the exact near-field distribution of different flaws in a high-density grating, which is impossible to obtain with the conventional Fourier transform method. The numerical results indicate that if a grating is perfect, its Talbot imaging should also be perfect; if the grating is distorted, its Talbot imaging will also be distorted. Furthermore, we evaluate high-density gratings by detecting the near-field distribution with the scanning near-field optical microscopy technique. Experimental results are also given. (c) 2005 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Talbot effect of a grating with different flaws is analyzed with the finite-difference time-domain (FDTD) method. The FDTD method can show the exact near-field distribution of different flaws in a high-density grating, which is impossible to obtain with the conventional Fourier transform method. The numerical results indicate that if a grating is perfect, its Talbot imaging should also be perfect; if the grating is distorted, its Talbot imaging would also be distorted. Furthermore, we can evaluate high density gratings by detecting the near-field distribution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

为减少噪声对相位恢复过程的影响,快速得到正确的解包裹相位,提出了一种改进的相位解包裹方法——加权离散余弦变换解包裹算法。该方法把离散余弦变换和标识相位数据好坏的质量权值结合起来,兼有速度快和可靠度高的优势。为验证此算法,对模拟和实验得到的包裹相位图添加随机噪声和散粒噪声,同时采用加权与非加权离散余弦变换算法进行处理,所得到的解包裹结果与未加噪声的解包裹相位值进行比较,结果表明,通过加权离散余弦变换算法恢复的相位图比非加权离散余弦变换算法所恢复的相位图更接近于理想值,而且两种算法的运行速度基本相同,这证明提

Relevância:

80.00% 80.00%

Publicador:

Resumo:

报道了基于双面反射镜的N×N光开关器件。介绍了使用双面反射镜的2×2, 4×4光开关的集成光路设计和工作原理; 采用Benes网络, 以2×2和4×4光开关为基本单元的N×N光开关器件的整体结构, 并根据“一笔画”原理, 分析了4×4, 8×8和16×16光开关矩阵的可重排无阻塞特性和光开关矩阵的光路选择算法。最后, 基于2×2, 4×4光开关技术制备了16×16光开关矩阵。测试表明, 该器件具有良好的插入损耗、回波损耗、串扰和开关时间等性能, 从而验证了设计思想和工艺的可行性。在基于双面反射镜的光开关矩

Relevância:

80.00% 80.00%

Publicador:

Resumo:

在正弦相位调制(SPM)干涉仪中,若调制频率或者采样频率发生变化将使干涉信号出现频谱泄漏,减小了谐波分量的幅值,在测量结果中引入了误差。对频谱泄漏的产生及其对测量精度的影响进行了理论分析,获得了频谱泄漏引入测量误差的计算方法。实验测得频率漂移量在-0.3~0.3 Hz内,得到的频谱泄漏引入的误差为0.3~7.9 nm,当超出这个范围时,频谱泄漏误差将迅速增长。实验结果与模拟分析结果一致。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

报道了一种新型双板条离轴混合腔激光器。这种激光器结构通过改变传统的冷却方式和采用特殊的谐振腔设计,将使从第一块介质板条高温一侧出射的激光对称地进入另一块板条的低温一侧,从而可对由于温度分布不均匀造成的波面畸变进行一定程度的自校正,减少热效应的影响,可望提高激光器的输出功率和光束质量。利用快速傅里叶变换(FFT)对这种激光器的近场、远场以及相位等模场特性进行了数值计算。分析了波面畸变对输出光束质量的影响,并与常规双板条激光器进行了比较,结果表明这种新型双板条离轴混合腔激光器可以实现一定程度的波面畸变自补偿,

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel dual-slab laser with off-axis one-sided hybrid resonator is presented. The mode properties of the hybrid resonator are calculated using a fast Fourier transform method (FFT). The influence of wavefront distoration on the output beam quality is considered. Results indicate that the novel dual-slab laser is better than the normal dual-slab laser with off-axis one-sided hybrid resonator.