17 resultados para Fly-ash


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the glass formation theory is applied to study the formation mechanism of the low leaching glassy slag during the process of plasma waste treatment. The research shows that SiO2 acts as network former to form a 3-dimensional Si-O tetrahedral network in which heavy metals are bonded or encapsulated, so the Si-O tetrahedron protect heavy metals against leaching from the vitrified slag or acid corrosion. For given chemical compositions of waste, the formation ability of the vitrified slag can be represented by the ratio of the whole oxygen ions to the whole network former ions in glass (O/Si) which is appropriate in the range of 2~3. A plasma arc reactor is used to conduct the vitrification experiments of two kinds of fly ashes with additives in which effects of various parameters including arc power, cooling speed, treatment temperature are studied. The chemical compositions of fly ashes are analyzed by X-ray fluorescence (XRF) spectrometry. The experimental results show that both cooling speed and O/Si have important influence on the formation of the vitrified slag, which is qualitatively in accordance with the predictions of the glass formation theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The leaching of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was measured in soil and standard fly ash column eluted with pure water and linear alkylbenzene sulfonate (LAS)- water. The data obtained were used to evaluate the leachability of PCDD/Fs from waste dump like incineration residual slag and fly ash deposition. The leaching rate was shown to be increased significantly by using LAS water. The leachate contents of PCDD/Fs were above their known water solubility. Concentration of PCDD/Fs in the leachates as well as the relative leaching (calculated on the fly ash content) increased with increasing chlorinating degree and decreasing water solubility. LAS above the critical micelle concentration (CMC) probably enhances PCDD/Fs solubility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper deals with an experimental study of air staging in a 1 MW (heat input power) tangentially fired pulverized coal furnace. The influences of several variables associated with air staging on NOx reduction efficiency and unburned carbon in fly ash were investigated, and these variables included the air stoichiometric ratio of primary combustion zone (SR1), the locations of over-fire air nozzles along furnace height, and the ratio of coal concentration of the fuel-rich stream to that of the fuel-lean one (RRL) in primary air nozzle. The experimental results indicate that SR1 and RRL have optimum values for NOx reduction, and the two optimum values are 0.85 and 3:1, respectively. NO, reduction efficiency monotonically increases with the increase of OFA nozzle location along furnace height. On the optimized operating conditions of air staging, NOx reduction efficiency can attain 47%. Although air staging can effectively reduce NOx emission, the increase of unburned carbon in fly ash should be noticed. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Full-scale experiments were performed on a 300 MWe utility boiler retrofitted with air staging. In order to improve boiler thermal efficiency and to reduce NOx emission, the influencing factors including the overall excessive air ratio, the secondary air distribution pattern, the damper openings of CCOFA and SOFA, and pulverized coal fineness were investigated. Through comprehensive combustion adjustment, NOx emission decreased 182 ppm (NOx reduction efficiency was 44%), and boiler heat efficiency merely decreased 0.21%. After combustion improvement, high efficiency and low NOx emission was achieved in the utility coal-fired boiler retrofitted with air staging, and the unburned carbon in ash can maintain at a desired level where the utilization of fly-ash as byproducts was not influenced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Extraction experiments with spiking of C-13(12)-PCDD/Fs were performed with a variety of PCDD/Fs contaminated samples. The extraction recovery of PCDD/Fs was mainly influenced by PCDD/Fs concentration and the sample matrix. Generally, the first soxhlet extraction with toluene has suitable recovery. From the selected samples, only FAMS4 and 5 which are fly ashes with high concentration, the recovery of the first soxhlet extraction with 24 hr. is low, but PCDD/Fs were almost completely removed after 72 hr. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, studies were carried out on the extraction properties of Mn(II) and MnO4- in sulfuric acid medium using Cyanex 923. Effects of different variables on the extraction of Mn(II) and MnO4-, such as the concentrations of acid, the extractant, and the temperature, were investigated. Results indicated that Mn(II) was extracted weakly by Cyanex 923; however, MnO4- could be strongly extracted into the organic phase. The extraction mechanism of MnO4- was proposed, and the influence of MnO4- on the extraction of cerium was identified when KMnO4 as oxidizer added into the bastnasite sulfuric acid leaching liquor. As MnO4- was easier to be extracted into the organic phase than Ce(IV) and then lost its ability for oxidization, a new device was designed to realize sufficient oxidization of cerium from III to IV, and which has been applied to industrialization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Distributions of elements especially hazard trace elements in coals and their wastes from a coal fired power plant have been studied in detail using knowledge of Geology, Mineralogy, Geochemistry and Environmental chemistry. The key work is on the small particle sizes of fly ashes which escaped from electric precipitator and discharged into atmosphere. By means of X-ray powder diffraction (XRD) and scanning electron microscopy with energy-dispersive spectrometer (SEM-EDS), the characteristics of minerals and morphologies were studied. Different types of fly ash were formed in different stages and processes. More than 50% of small fly ashes belonged to inhalable particles (PM10). The very fine fly ashes preferred to attach on surface of bigger fly ash or conglutinate with each other and this decreased the environmental impact of tiny fly ashes. The trace elements in coal, fly ashes, slags and small particle sizes of fly ashes had been analysed by means of Neutron Activation Analysis (INAA), inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES). As particle sizes decreasing, distributions of most elements increased, but in contrary to most studies, this increasing trend was not very obviously because of the tendency of attachment of tiny fly ashes. The occurrence of 30 elements including hazard trace elements of Cd, Cr, Ni, Co, Pb, Zn, As, Se, Cu, V was studied by means of sequential chemical extract. The annual discharge of hazard trace elements of slag, fly ash, small fly ash (PM10), tiny fly ash (PM2.5) and air was calculated by mass balance. S, V, Cu, Pb, Se, Mo, Cd from power plant had potential impacts on environment. Hazard trace elements from the power plant had little effect on soil and aerosol comparing to those from other industrial sources and the effects were mostly on downwind direction. Both the high performance electric precipitator and high chimney made the hazard trace elements from power plant being transported far away but little environmental impacts.