10 resultados para testing, test, verifica, validazione
em Cambridge University Engineering Department Publications Database
Resumo:
Transient test facilities offer the potential for the simultaneous study of turbine aerodynamic performance, unsteady flow phenomena and the heat transfer characteristics of a turbine stage. This paper describes the development of aerodynamic performance measurement techniques in the Oxford Rotor Facility (ORF). The solutions to the technological issues involved with transient testing presented in this paper are expected to achieve levels of precision uncertainty comparable with traditional steady flow test rigs. The theoretical background to the measurement of aerodynamic performance is presented together with a comprehensive pre-test uncertainty analysis. The instrumentation scheme for the measurement of stage mass flow rate is discussed in detail, the measurements of shaft power, total inlet enthalpy, and stage pressure ratio are also outlined. The current working section features a 62% scale, 1-1/2 stage, high-pressure shroudless transonic turbine. The required inlet flow conditions are provided by an Isentropic Light Piston Tunnel (ILPT) with a quasi-steady state run time of approximately 70ms. The testing is conducted at engine representative specific speed, pressure ratio, gas-to-wall temperature ratio, Mach number and Reynolds number.
Resumo:
Previously published expressions for the wear volume in the micro-scale abrasion test for curved specimen surfaces (K.L. Rutherford and I.M. Hutchings, Tribology Letters 2 (1996) 1-11) were based upon erroneous assumptions about the wear-scar geometry. Accurate volumes have now been computed, and the errors in the use of the original analytical equations are shown to be negligibly small (<0.5% error) for all practical cases. © J.C. Baltzer AG, Science Publishers.
Resumo:
Purpose: This paper seeks to measure in a quantitative way the degree of alignment among a set of performance measures between two organizations. Design/methodology/approach: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. The authors applied the test and present coefficients of misalignment across three sets of measures: those used by a service provider involved in the research, those used by customers contracting the services, and those documented in 11 contracts studied. Findings: Results confirmed a high degree of alignment between target and actual operational performance in the contracts. The alignment of customers' financial objectives and contracts' operational metrics was low. Calculations show poor alignment between the objectives of the provider and the contribution received from the contracts. Research limitations/implications: Some limitations of the conclusions include the small sample of contracts used in the calculations. Further research should include not only actual contracts, but also failed ones. Practical implications: It is possible that misaligned goals, represented in misaligned performance measures, lead to tensions in intra-firm relationships. If these tensions are not addressed properly the relationship could be unstable or terminated prematurely. This method of measuring alignment could detect early potential dangers in intra-firm relationships. Originality/value: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. Management researchers and business professionals may use this methodology when exploring degrees of alignment of performance measures in intra-functional and inter-firm relationships. © Emerald Group Publishing Limited.
Resumo:
Brittleness is the unintended, but inevitable consequence of producing a transparent ceramic for architectural applications such as the soda-lime glass. Its tensile strength is particularly sensitive to surface imperfections, such as that from natural weathering and malicious damage. Although a significant amount of testing of new glass has been carried out, there has been surprisingly little testing on weathered glass. Due to the variable nature of the causes of surface damage, the lack of data on weathered glass leads to a considerable degree of uncertainty in the long-term strength of exposed glass. This paper presents the results of recent tests on weathered annealed glass which has been exposed to natural weathering for more than 20 years. The tests include experimental investigations using the co-axial ring setup as well as optical and atomic force microscopy of the glass surfaces. The experimental data from these tests is subsequently used to extend existing fracture mechanics-based models to predict the strength of weathered glass. It is shown that using an automated approach based directly on finite element analysis results can give an increase in effective design strength in the order of 70 to 100% when compared to maximum stress methods. It is also shown that by combining microscopy and strength test results, it is possible to quantitatively characterise the damage on glass surfaces.
Resumo:
The lack of viable methods to map and label existing infrastructure is one of the engineering grand challenges for the 21st century. For instance, over two thirds of the effort needed to geometrically model even simple infrastructure is spent on manually converting a cloud of points to a 3D model. The result is that few facilities today have a complete record of as-built information and that as-built models are not produced for the vast majority of new construction and retrofit projects. This leads to rework and design changes that can cost up to 10% of the installed costs. Automatically detecting building components could address this challenge. However, existing methods for detecting building components are not view and scale-invariant, or have only been validated in restricted scenarios that require a priori knowledge without considering occlusions. This leads to their constrained applicability in complex civil infrastructure scenes. In this paper, we test a pose-invariant method of labeling existing infrastructure. This method simultaneously detects objects and estimates their poses. It takes advantage of a recent novel formulation for object detection and customizes it to generic civil infrastructure scenes. Our preliminary experiments demonstrate that this method achieves convincing recognition results.
Resumo:
Distributed hybrid testing is a natural extension to and builds upon the local hybrid testing technique. Taking advantage of the hybrid nature of the test, it allows a sharing of resources and expertise between researchers from different disciplines by connecting multiple geographically distributed sites for joint testing. As part of the UK-NEES project, a successful series of three-site distributed hybrid tests have been carried out between Bristol, Cambridge and Oxford Universities. The first known multi-site distributed hybrid tests in the UK, they connected via a dedicated fibre network, using custom software, the geotechnical centrifuge at Cambridge to structural components at Bristol and Oxford. These experiments were to prove the connection and useful insights were gained into the issues involved with this distributed environment. A wider aim is towards providing a flexible testing framework to facilitate multi-disciplinary experiments such as the accurate investigation of the influence of foundations on structural systems under seismic and other loading. Time scaling incompatibilities mean true seismic soil structure interaction using a centrifuge at g is not possible, though it is clear that distributed centrifuge testing can be valuable in other problems. Development is continuing to overcome the issues encountered, in order to improve future distributed tests in the UK and beyond.
Resumo:
A new simple shear testing device capable of applying multidirectional loading to soil specimens has been developed. The Texas A&M University multidirectional simple shear (TAMU-MDSS) device provides the ability to apply a large range of shear stresses and complex loading paths, such as figure-eight and circular patterns, to a cylindrical soil specimen confined by a wire-reinforced membrane. The load and torque experienced by the sample are directly measured by a multi-axis load cell installed above the specimen. Backpressure saturation of the specimen is made possible by the devicés ability to apply pressure in the chamber and backpressure to the water lines. Excess pore pressure is measured by a pressure transducer during the shearing phase of the testing. This paper describes the development of the TAMU-MDSS system and the capabilities of the device and presents test results on saturated clay soil specimens subjected to monotonic, unidirectional cyclic, and multidirectional loading. Copyright © 2013 by ASTM International.