9 resultados para standard deviation

em Cambridge University Engineering Department Publications Database


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To examine the role of androgens on birth weight in genetic models of altered androgen signalling. SETTING: Cambridge Disorders of Sex Development (DSD) database and the Swedish national screening programme for congenital adrenal hyperplasia (CAH). PATIENTS: (1) 29 girls with XY karyotype and mutation positive complete androgen insensitivity syndrome (CAIS); (2) 43 girls and 30 boys with genotype confirmed CAH. MAIN OUTCOME MEASURES: Birth weight, birth weight-for-gestational-age (birth weight standard deviation score (SDS)) calculated by comparison with national references. RESULTS: Mean birth weight SDS in CAIS XY infants was higher than the reference for girls (mean, 95% CI: 0.4, 0.1 to 0.7; p=0.02) and was similar to the national reference for boys (0.1, -0.2 to 0.4). Birth weight SDS in CAH girls was similar to the national reference for girls (0.0, -0.2 to 0.2) and did not vary by severity of gene mutation. Birth weight SDS in CAH boys was also similar to the national reference for boys (0.2, -0.2 to 0.6). CONCLUSION: CAIS XY infants have a birth weight distribution similar to normal male infants and birth weight is not increased in infants with CAH. Alterations in androgen signalling have little impact on birth weight. Sex dimorphism in birth size is unrelated to prenatal androgen exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new method for measuring the coefficient of friction between nonwoven materials and the curved surface of the volar forearm has been developed and validated. The method was used to measure the coefficient of static friction for three different nonwoven materials on the normal (dry) and over-hydrated volar forearms of five female volunteers (ages 18-44). The method proved simple to run and had good repeatability: the coefficient of variation (standard deviation expressed as a percentage of the mean) for triplets of repeat measurements was usually (80 per cent of the time) less than 10 per cent. Measurements involving the geometrically simpler configuration of pulling a weighted fabric sample horizontally across a quasi-planar area of volar forearm skin proved experimentally more difficult and had poorer repeatability. However, correlations between values of coefficient of static friction derived using the two methods were good (R = 0.81 for normal (dry) skin, and 0.91 for over-hydrated skin). Measurements of the coefficient of static friction for the three nonwovens for normal (dry) and for over-hydrated skin varied in the ranges of about 0.3-0.5 and 0.9-1.3, respectively. In agreement with Amontons' law, coefficients of friction were invariant with normal pressure over the entire experimental range (0.1-8.2 kPa).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Negative feedback is common in biological processes and can increase a system's stability to internal and external perturbations. But at the molecular level, control loops always involve signalling steps with finite rates for random births and deaths of individual molecules. Here we show, by developing mathematical tools that merge control and information theory with physical chemistry, that seemingly mild constraints on these rates place severe limits on the ability to suppress molecular fluctuations. Specifically, the minimum standard deviation in abundances decreases with the quartic root of the number of signalling events, making it extremely expensive to increase accuracy. Our results are formulated in terms of experimental observables, and existing data show that cells use brute force when noise suppression is essential; for example, regulatory genes are transcribed tens of thousands of times per cell cycle. The theory challenges conventional beliefs about biochemical accuracy and presents an approach to the rigorous analysis of poorly characterized biological systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In concentrated contacts the behaviour of lubricants is much modified by the high local pressures: changes can arise both from molecular ordering within the very thin film lubricant layers present at the interface as well as from the deposition on the component surfaces of more solid-like polymeric boundary layers. These 'third bodies' separating the solid surfaces may have rheological or mechanical properties very different from those observed in the bulk. Classical elasto-hydrodynamic theory considers the entrapped lubricant to exhibit a piezo-viscous behaviour while the conventional picture of more solid boundary lubricant layers views their shear strength r as being linearly dependent on local pressure p, so that T = TO + ap where TO and a are constants. If TO is relatively small, then the coefficient of friction \i = T Ip ~ a and so Amonton's laws are recovered. However, the properties of adsorbed or deposited surface films, or indeed other third bodies such as debris layers, may be more complex than this. A preliminary study has looked quantitatively at the influence of the pressure dependence of the shear strength of any surface layer on the overall friction coefficient of a contact which is made up of an array of asperities whose height varies in a Gaussian manner. Individual contact points may be elastic or plastic. The analysis results in plots of coefficient of friction versus the service or load parameter PIH&NRa where P is the nominal pressure on the contact, HS the hardness of the deforming surface, N the asperity density, R the mean radius of curvature of the asperities, and a is the standard deviation of their height distribution. In principle, any variation oft withp can be incorporated into the model; however, in this initial study we have used data on colloidal suspensions from the group at the Ecole Centrale de Lyon as well as examining the effect of functional relationships of somewhat greater complexity than a simple linear form. Results of the analysis indicate that variations in fj. are possible as the load is varied which depend on the statistical spread of behaviour at individual asperity contacts. The value of this analysis is that it attempts to combine the behaviour of films on the molecular scale with the topography of real engineering surfaces and so give an indication of the effects at the full-size or macro-scale that can be achieved by chemical or molecular surface engineering.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to disign an airfoil of which maximum lift coefficient (CL max) is not sensitive to location of forced top boundary layer transition. Taking maximizing mean value of CL max and minimizing standard deviation as biobjective, leading edge radius, manximum thickness and its location, maximum camber and its location as deterministic design variables, location of forced top boundary layer transition as stochastic variable, XFOIL as deterministic CFD solver, non-intrusive polynomial chaos as substitute of Monte Carlo method, we completed a robust airfoil design problem. Results demonstrate performance of initial airfoil is enhanced through reducing standard deviation of CL max. Besides, we also know maximum thickness has the most dominating effect on mean value of CL max, location of maximum thickness has the most dominating effect on standard deviation of CL max, maximum camber has a little effect on both mean value and standard deviation, and maximum camber is the only element of which increase can lead increase of mean value and standard deviation at the same time. Copyright © 2009 by the American Institute of Aeronautics and Astronautics, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, we report on the realisation of a free space deposition process (FSD). For the first time the use of a moving support structure to deposit tracks of metal starting from a substrate and extending into free space is characterised. The ability to write metal shapes in free space has wide ranging applications in additive manufacturing and rapid prototyping where the tracks can be layered to build overhanging features without the use of fixed support structures (such as is used in selective laser melting (SLM) and stereo lithography (SLA)). We demonstrate and perform a preliminary characterisation of the process in which a soldering iron was used to deposit lead free solder tracks. The factors affecting the stability of tracks and the effect of operating parameters, temperature, velocity, initial track starting diameter and starting volume were measured. A series of 10 tracks at each setting were compared with a control group of tracks; the track width, taper and variation between tracks were compared. Notable results in free space track deposition were that the initial track diameter and volume affected the repeatability and quality of tracks. The standard deviation of mean track width of tracks from the constrained initial diameter group were half that of the unconstrained group. The amount of material fed to the soldering iron before commencing deposition affected the taper of tracks. At an initial volume of 7 mm3 and an initial track diameter of 0.8 mm, none of the ten tracks deposited broke or showed taper > ∼1°. The maximum deposition velocity for free space track deposition using lead-free solder was limited to 1.5 mm s-1. © 2011 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Deformations of sandy soils around geotechnical structures generally involve strains in the range small (0·01%) to medium (0·5%). In this strain range the soil exhibits non-linear stress-strain behaviour, which should be incorporated in any deformation analysis. In order to capture the possible variability in the non-linear behaviour of various sands, a database was constructed including the secant shear modulus degradation curves of 454 tests from the literature. By obtaining a unique S-shaped curve of shear modulus degradation, a modified hyperbolic relationship was fitted. The three curve-fitting parameters are: an elastic threshold strain γe, up to which the elastic shear modulus is effectively constant at G0; a reference strain γr, defined as the shear strain at which the secant modulus has reduced to 0·5G0; and a curvature parameter a, which controls the rate of modulus reduction. The two characteristic strains γe and γr were found to vary with sand type (i.e. uniformity coefficient), soil state (i.e. void ratio, relative density) and mean effective stress. The new empirical expression for shear modulus reduction G/G0 is shown to make predictions that are accurate within a factor of 1·13 for one standard deviation of random error, as determined from 3860 data points. The initial elastic shear modulus, G0, should always be measured if possible, but a new empirical relation is shown to provide estimates within a factor of 1·6 for one standard deviation of random error, as determined from 379 tests. The new expressions for non-linear deformation are easy to apply in practice, and should be useful in the analysis of geotechnical structures under static loading.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hip fracture is the leading cause of acute orthopaedic hospital admission amongst the elderly, with around a third of patients not surviving one year post-fracture. Although various preventative therapies are available, patient selection is difficult. The current state-of-the-art risk assessment tool (FRAX) ignores focal structural defects, such as cortical bone thinning, a critical component in characterizing hip fragility. Cortical thickness can be measured using CT, but this is expensive and involves a significant radiation dose. Instead, Dual-Energy X-ray Absorptiometry (DXA) is currently the preferred imaging modality for assessing hip fracture risk and is used routinely in clinical practice. Our ambition is to develop a tool to measure cortical thickness using multi-view DXA instead of CT. In this initial study, we work with digitally reconstructed radiographs (DRRs) derived from CT data as a surrogate for DXA scans: this enables us to compare directly the thickness estimates with the gold standard CT results. Our approach involves a model-based femoral shape reconstruction followed by a data-driven algorithm to extract numerous cortical thickness point estimates. In a series of experiments on the shaft and trochanteric regions of 48 proximal femurs, we validated our algorithm and established its performance limits using 20 views in the range 0°-171°: estimation errors were 0:19 ± 0:53mm (mean +/- one standard deviation). In a more clinically viable protocol using four views in the range 0°-51°, where no other bony structures obstruct the projection of the femur, measurement errors were -0:07 ± 0:79 mm. © 2013 SPIE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, we present a study on electrical and optical characteristics of n-type tin-oxide nanowires integrated based on top-down scale-up strategy. Through a combination of contact printing and plasma based back-channel passivation, we have achieved stable electrical characteristics with standard deviation in mobility and threshold voltage of 9.1% and 25%, respectively, for a large area of 1× 1 cm2 area. Through use of contact printing, high alignment of nanowires was achieved thus minimizing the number of nanowire-nanowire junctions, which serve to limit carrier transport in the channel. In addition, persistent photoconductivity has been observed, which we attribute to oxygen vacancy ionization and subsequent elimination using a gate pulse driving scheme. © 2014 IEEE.