44 resultados para smoke filling

em Cambridge University Engineering Department Publications Database


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The present paper explores the influence of room geometry on the overturning of smoke owing to a centrally located floor fire, and examines the implications on smoke filling times. The focus is on presenting practical design guidelines based on the theoretical predictions of the model of Kaye and Hunt. An engineering platform is developed for the prediction of smoke filling times, and a rational basis is provided by way of which smoke behaviour can be specified for simple room designs. The time taken for smoke to fill a room to a given height is critically affected by the room aspect ratio and the characteristic size of the buoyancy source. At large times, taller (small aspect ratio) rooms are shown to fill with smoke at a faster rate than wide (large aspect ratio) rooms owing to large-scale overturning and engulfing of ambient air during the initial transients. Larger area sources of buoyancy also decrease significantly the smoke filling times, with important implications for fire and smoke safety design. Simplified design curves incorporating the main findings have been developed for use as a tool by practising fire-safety engineers.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter, we report E off-versus-V ce tradeoff curves for vertical superjunction insulated-gate bipolar transistors (SJ IGBTs), exhibiting unusual inverse slopes dE off/dV ce > 0 in a transition region between purely unipolar and strongly bipolar device behaviors. This effect is due to the action of p-pillar hole current when depleting the drift layer of SJ IGBTs during turnoff and the impact of current gain on the transconductance. Such SJ IGBTs surpass by a very significant margin their superjunction MOSFET counterparts in terms of power-handling capability and on-state and turnoff losses, all at the same time. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel real time smoke sensor is described, which is mounted in the exhaust manifold and detects the smoke by virtue of the natural electrical charge which is carried on the smoke. The somewhat obscure origin of the charge on the smoke is briefly considered, as well as the operation of the sensor itself. The use of the sensor as part of a feedback control shows that it can be very effective in reducing smoke puffs. Copyright © 1987 Society of Automotive Engineers, Inc.