46 resultados para reactors in series

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper an Active Voltage Control (AVC) technique is presented, for series connection of insulated-gate-bipolar-transistors (IGBT) and control of diode recovery. The AVC technique can control the switching trajectory of an IGBT according to a pre-set reference signal. In series connections, every series connected IGBT follows the reference and so that the dynamic voltage sharing is achieved. Another key advantage for AVC is that by changing the reference signal at turn-on, the diode recovery can be optimised. © 2010 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper an Active Voltage Control (AVC) technique is presented, for series connection of insulated-gate-bipolar-transistors (IGBT) and control of diode recovery. The AVC technique can control the switching trajectory of an IGBT according to a pre-set reference signal. In series connections, every series connected IGBT follows the reference and so that the dynamic voltage sharing is achieved. For the static voltage balancing, the AVC technique can clamp the highest collector-to-emitter voltage to a pre-set clamping voltage level. By selecting the value of the clamping voltage, the difference among series connected IGBTs can be controlled in an accepted range. Another key advantage for AVC is that by changing the reference signal at turn-on, the diode recovery can be optimized. © 2011 EPE Association - European Power Electr.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A superconducting fault current limiter (SFCL) in series with a downstream circuit breaker could provide a viable solution to controlling fault current levels in electrical distribution networks. In order to integrate the SFCL into power grids, we need a way to conveniently predict the performance of the SFCL in a given scenario. In this paper, short circuit analysis based on the electromagnetic transient program was used to investigate the operational behavior of the SFCL installed in an electrical distribution grid. System studies show that the SFCL can not only limit the fault current to an acceptable value, but also mitigate the voltage sag. The transient recovery voltage (TRV) could be remarkably damped and improved by the presence of the SFCL after the circuit breaker is opened to clear the fault. © 2007 British Crown Copyright.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents the use of an Active Voltage Control (AVC) technique for balancing the voltages in a series connection of Insulated Gate Bipolar Transistors (IGBTs). The AVC technique can control the switching trajectory of an IGBT according to a pre-set reference signal. In series connections, every series connected IGBT follows the reference and so that the dynamic voltage sharing is achieved. For the static voltage balancing, a temporary clamp technique is introduced. The temporary clamp technique clamps the collector-emitter voltage of all the series connected IGBTs at the ideal voltage so that the IGBTs will share the voltage evenly. © 2012 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The paper shows that generating cross sections using three-dimensional geometry and application of axial discontinuity factors are essential requirements for obtaining accurate prediction of criticality and zone average reaction rates in highly heterogeneous RBWR-type systems using computer codes based on diffusion theory approximation. The same methodology as presented here will be used to generate discontinuity factors for each axial interface between fuel assembly zones to ensure preservation of reaction rates in each zone and global multiplication factor. The use of discontinuity factors and three-dimensional cross sections may allow for a coarser energy group structure which is desirable to simplify and speed up transient calculations.