14 resultados para phase measurement

em Cambridge University Engineering Department Publications Database


Relevância:

40.00% 40.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The optical efficiency of GaN-based multiple quantum well (MQW) and light emitting diode (LED) structures grown on Si(111) substrates by metal-organic vapor phase epitaxy was measured and compared with equivalent structures on sapphire. The crystalline quality of the LED structures was comprehensively characterized using x-ray diffraction, atomic force microscopy, and plan-view transmission electron microscopy. A room temperature photoluminescence (PL) internal quantum efficiency (IQE) as high as 58% has been achieved in an InGaN/GaN MQW on Si, emitting at 460 nm. This is the highest reported PL-IQE of a c-plane GaN-based MQW on Si, and the radiative efficiency of this sample compares well with similar structures grown on sapphire. Processed LED devices on Si also show good electroluminescence (EL) performance, including a forward bias voltage of ∼3.5 V at 20 mA and a light output power of 1 mW at 45 mA from a 500 ×500 μm2 planar device without the use of any additional techniques to enhance the output coupling. The extraction efficiency of the LED devices was calculated, and the EL-IQE was then estimated to have a maximum value of 33% at a current density of 4 A cm-2, dropping to 30% at a current density of 40 A cm-2 for a planar LED device on Si emitting at 455 nm. The EL-IQE was clearly observed to increase as the structural quality of the material increased for devices on both sapphire and Si substrates. © 2011 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the first measurement of two-photon absorption (TPA) and self-phase modulation in an InGaAsP/InP multi-quantum-well waveguide. The TPA coefficient, β2, was found to be 60±10 cm/GW at 1.55 μm. Despite operating at 200 nm from the band edge, self-phase modulation as high as 8±2 rad was observed for 30-ps optical pulses at 3.8-W peak input power. A theoretical calculation indicates that this enhanced phase modulation is primarily due to bandfilling in the quantum wells and the free-carrier plasma effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nano-phase (5-20 nm) particles of YBa2(Cu0.5M 0.6)O6 [where M = Nb, Ta, Mo, W, Zr and Hf] have been introduced successfully into RE-Ba-Cu-O single grain superconductors. A study to enlarge the size of a single grain containing these particles has been carried out involving measurement of the growth rate as a function of YBa 2(Cu0.5M0.6)O6 phase concentration and degree of un-dercooling. The influence of the change in YBa2 (Cu0.8M0.5)O6 concentration on microstructural features is also investigated and the superconducting properties of these large grain superconductors are presented. © 2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A tribometer, based on a pin-on-disc machine, uses a PZT drive to produce small sinusoidal fluctuations of sliding speed. The frequency and amplitude of these fluctuations can be controlled, and the dynamic response measured. Preliminary test results show that the dynamic friction variation is influenced by the contact materials, normal force, oscillation frequency and steady sliding speed. The variation of friction force amplitude and phase with frequency gives clues about the underlying state variables determining the friction. Modelling studies illustrate the expected behaviour for idealized friction laws governed by, for example, sliding speed, contact temperature, and "rate-state" laws. © 2008 SAE International.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement of cantilever parameters is an essential part of performing a calibrated measurement with an atomic force microscope (AFM). The thermal motion method is a widely used technique for calibrating the spring constant of an AFM cantilever, which can be applied to non-rectangular cantilevers. Given the trend towards high frequency scanning, calibration of non-rectangular cantilevers is of increasing importance. This paper presents two results relevant to cantilever calibration via the thermal motion method. We demonstrate the possibility of using the AFM's phase signal to acquire the thermal motion. This avoids the challenges associated with connecting the raw photodiode signal to a separate spectrum analyser. We also describe how numerical calculations may be used to calculate the parameters needed in a thermal motion calibration of a non-rectangular cantilever. Only accurate knowledge of the relative size of the in-plane dimensions of the cantilever is needed in this computation. We use this pair of results in the calibration of a variety of rectangular and non-rectangular cantilevers. We observe an average difference between the Sader and thermal motion values of cantilever stiffness of 10%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A tribometer, based on a pin-on-disc machine, uses a PZT drive to produce small sinusoidal fluctuations of sliding speed. The frequency and amplitude of these fluctuations can be controlled, and the dynamic response measured. Preliminary test results show that the dynamic friction variation is influenced by the contact materials, normal force, oscillation frequency and steady sliding speed. The variation of friction force amplitude and phase with frequency gives clues about the underlying state variables determining the friction. Modelling studies illustrate the expected behaviour for idealized friction laws governed by, for example, sliding speed, contact temperature, and "rate-state" laws. © 2008 SAE International.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Performance measurement and management (PMM) is a management and research paradox. On one hand, it provides management with many critical, useful, and needed functions. Yet, there is evidence that it can adversely affect performance. This paper attempts to resolve this paradox by focusing on the issue of "fit". That is, in today's dynamic and turbulent environment, changes in either the business environment or the business strategy can lead to the need for new or revised measures and metrics. Yet, if these measures and metrics are either not revised or incorrectly revised, then we can encounter situations where what the firm wants to achieve (as communicated by its strategy) and what the firm measures and rewards are not synchronised with each other (i.e., there is a lack of "fit"). This situation can adversely affect the ability of the firm to compete. The issue of fit is explored using a three phase Delphi approach. Initially intended to resolve this first paradox, the Delphi study identified another paradox - one in which the researchers found that in a dynamic environment, firms do revise their strategies, yet, often the PMM system is not changed. To resolve this second paradox, the paper proposes a new framework - one that shows that under certain conditions, the observed metrics "lag" is not only explainable but also desirable. The findings suggest a need to recast the accepted relationship between strategy and PMM system and the output included the Performance Alignment Matrix that had utility for managers. © 2013 .