Resumo:
Board-level optical links are an attractive alternative to their electrical counterparts as they provide higher bandwidth and lower power consumption at high data rates. However, on-board optical technology has to be cost-effective to be commercially deployed. This study presents a chip-to-chip optical interconnect formed on an optoelectronic printed circuit board that uses a simple optical coupling scheme, cost-effective materials and is compatible with well-established manufacturing processes common to the electronics industry. Details of the link architecture, modelling studies of the link's frequency response, characterisation of optical coupling efficiencies and dynamic performance studies of this proof-of-concept chip-to-chip optical interconnect are reported. The fully assembled link exhibits a -3 dBe bandwidth of 9 GHz and -3 dBo tolerances to transverse component misalignments of ±25 and ±37 μm at the input and output waveguide interfaces, respectively. The link has a total insertion loss of 6 dBo and achieves error-free transmission at a 10 Gb/s data rate with a power margin of 11.6 dBo for a bit-error-rate of 10 -12. The proposed architecture demonstrates an integration approach for high-speed board-level chip-to-chip optical links that emphasises component simplicity and manufacturability crucial to the migration of such technology into real-world commercial systems. © 2012 The Institution of Engineering and Technology.
Resumo:
This paper explores the current state-of-the-art in performance indicators and use of probabilistic approaches used in climate change impact studies. It presents a critical review of recent publications in this field, focussing on (1) metrics for energy use for heating and cooling, emissions, overheating and high-level performance aspects, and (2) uptake of uncertainty and risk analysis. This is followed by a case study, which is used to explore some of the contextual issues around the broader uptake of climate change impact studies in practice. The work concludes that probabilistic predictions of the impact of climate change are feasible, but only based on strict and explicitly stated assumptions. © 2011 Elsevier B.V. All rights reserved.
Resumo:
As part of a study of the wear of candidate heat exchanger tube materials for use in fluidized bed combustors, two similar laboratory-scale rigs have been built and characterized. Specimens of selected alloys are carried on counter-rotating rotors immersed in a fluidized bed, and are exposed to particle impact velocities of up to approximately 3 ms-1 at temperatures up to 1000°C. The performance of this design of apparatus has been investigated in detail. The effects of several experimental variables have been studied, including angle of particle impact, specimen speed, position of the rotor within the fluidized bed, duration of exposure, bed material particle size, degradation of the bed material, degree of fluidization of the bed, and size of specimen. In many cases the results obtained with steel specimens at elevated temperatures are similar to those observed with polymeric specimens at low temperatures.
Resumo:
Diamond-like carbon (DLC) coatings were deposited on to silicon, glass and metal substrates, using an rf-plasma enhanced chemical vapour deposition (rf-PECVD) process. The resultant film properties were evaluated in respect of material and interfacial property control, based on bias voltage variation and the introduction of inert (He and Ar) and reactive (N2) diluting gases in a CH4 plasma. The analysis techniques used to assess the material properties of the films included AFM, EELS, RBS/ERDA, spectroscopic, electrical, stress, microhardness, and adhesion. These were correlated to the tribological performance of the coatings using wear measurements. The most important observation is that He dilution (>90%) promotes enhanced adhesion with respect to all substrate material studies. Coatings typically exhibit a microhardness of the order of 10-20 GPa in films 0.1
Resumo:
This paper will report studies of the placement of 2D photonic gratings on either side of the ridge in a Fabry Perot laser device in order to cause single mode emission. Using this approach, side mode suppression ratios of up to 30 dB are achieved, the emission remaining single mode even under 10 Gb/s large signal modulation. It is found that the use of the grating not only causes spectrally dependent reflection but in addition can lead to transverse mode fluctuations. The action of the grating has been studied not just in terms of its edge emission where conversion of the transverse modes is achieved, but also through measurement of the vertical emission from the structure where strong filtering action is observed.
Resumo:
Climate change is expected to have significant impact on the future thermal performance of buildings. Building simulation and sensitivity analysis can be employed to predict these impacts, guiding interventions to adapt buildings to future conditions. This article explores the use of simulation to study the impact of climate change on a theoretical office building in the UK, employing a probabilistic approach. The work studies (1) appropriate performance metrics and underlying modelling assumptions, (2) sensitivity of computational results to identify key design parameters and (3) the impact of zonal resolution. The conclusions highlight the importance of assumptions in the field of electricity conversion factors, proper management of internal heat gains, and the need to use an appropriately detailed zonal resolution. © 2010 Elsevier B.V. All rights reserved.
Resumo:
Climate change is becoming a serious issue for the construction industry, since the time scales at which climate change takes place can be expected to show a true impact on the thermal performance of buildings and HVAC systems. In predicting this future building performance by means of building simulation, the underlying assumptions regarding thermal comfort conditions and the related heating, ventilating and air conditioning (HVAC) control set points become important. This article studies the thermal performance of a reference office building with mixedmode ventilation in the UK, using static and adaptive thermal approaches, for a series of time horizons (2020, 2050 and 2080). Results demonstrate the importance of the implementation of adaptive thermal comfort models, and underpin the case for its use in climate change impact studies. Adaptive thermal comfort can also be used by building designers to make buildings more resilient towards change. © 2010 International Building Performance Simulation Association (IBPSA).
Resumo:
This article reports on the use of building performance simulation to quantify the risks that climate change poses to the thermal performance of buildings, and to their critical functions. Through a number of case studies the article demonstrates that any prediction of the probable thermal building performance on the long timeframes inherent in climate change comes with very large uncertainties. The same cases are used to illustrate that assessing the consequences of predicted change is problematic, since the functions that the building provides in themselves often are a moving target. The article concludes that quantification of the risks posed by climate change is possible, but only with many restrictions. Further research that is needed to move to more effective discussion about risk acceptance and risk abatement for specific buildings is identified. © 2012 Elsevier Ltd.
Resumo:
This paper begins with introducing the winding techniques of two superconducting double-pancake coils wound using 2G coated conductors. These winding techniques are able to guarantee a good performance for the superconducting coils. Then the coil critical currents were measured and compared with a simulation model. The results were consistent. Finally the coil AC losses were measured using an experimental circuit including a compensation coil. The simulation results are close to the experiment results. © 2010 IEEE.
Resumo:
A superconducting fault current limiter (SFCL) in series with a downstream circuit breaker could provide a viable solution to controlling fault current levels in electrical distribution networks. In order to integrate the SFCL into power grids, we need a way to conveniently predict the performance of the SFCL in a given scenario. In this paper, short circuit analysis based on the electromagnetic transient program was used to investigate the operational behavior of the SFCL installed in an electrical distribution grid. System studies show that the SFCL can not only limit the fault current to an acceptable value, but also mitigate the voltage sag. The transient recovery voltage (TRV) could be remarkably damped and improved by the presence of the SFCL after the circuit breaker is opened to clear the fault. © 2007 British Crown Copyright.