106 resultados para optical fiber amplifier

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the amplification of 10-100-pJ semiconductor diode pulses to an energy of 158 μJ and peak powers >100 kW in a multistage fiber amplifier chain based on a single-mode, large-mode-area erbium-doped amplifier design. To our knowledge these results represent the highest single-mode pulse energy extracted from any doped-fiber system. © 1997 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the amplification of 10-100-pJ semiconductor diode pulses to an energy of 158 microJ and peak powers >100 kW in a multistage fiber amplifier chain based on a single-mode, large-mode-area erbium-doped amplifier design. To our knowledge these results represent the highest single-mode pulse energy extracted from any doped-fiber system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optical fiber strain sensing technique, based on Brillouin Optical Time Domain Reflectometry (BOTDR), was used to obtain the full deformation profile of a secant pile wall during construction of an adjacent basement in London. Details of the installation of sensors as well as data processing are described. By installing optical fiber down opposite sides of the pile, the distributed strain profiles obtained can be used to give both the axial and lateral movements along the pile. Measurements obtained from the BOTDR were found in good agreement with inclinometer data from the adjacent piles. The relative merits of the two different techniques are discussed. © 2007 ASCE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper describes the use of optical fiber Brillouin Optical Time Domain Reflectometry (BOTDR) to monitor the strain distribution in an existing tunnel while a twin tunnel was bored at close-proximity. The twin circular bored tunnels between Serangoon and Bartley stations on the new Circle Line Stage 3 subway in Singapore were constructed at close-proximity to avoid underpinning the foundations of adjacent buildings. The minimum clear separation of the two tunnels is 2.3m (0.4 times the tunnel diameter). The Outer Tunnel was constructed first, followed by the Inner Tunnel, with the earth-pressure balance tunnel boring machines maintained at a minimum of 100m apart. In this trial application of BOTDR, the strain distribution along the Outer Tunnel was measured, in order to monitor its deformation due to the boring of the Inner Tunnel at close-proximity. The aim of the trial application was to determine the practicality of this monitoring method for future use in 'live' tunnels. This paper compares the measurements obtained from optical fiber BOTDR with conventional methods of tunnel monitoring and describes preliminary installation and workmanship guidelines derived from lessons learnt during this trial. © 2007 ASCE.