25 resultados para office building

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Climate change is becoming a serious issue for the construction industry, since the time scales at which climate change takes place can be expected to show a true impact on the thermal performance of buildings and HVAC systems. In predicting this future building performance by means of building simulation, the underlying assumptions regarding thermal comfort conditions and the related heating, ventilating and air conditioning (HVAC) control set points become important. This article studies the thermal performance of a reference office building with mixedmode ventilation in the UK, using static and adaptive thermal approaches, for a series of time horizons (2020, 2050 and 2080). Results demonstrate the importance of the implementation of adaptive thermal comfort models, and underpin the case for its use in climate change impact studies. Adaptive thermal comfort can also be used by building designers to make buildings more resilient towards change. © 2010 International Building Performance Simulation Association (IBPSA).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Climate change is expected to have significant impact on the future thermal performance of buildings. Building simulation and sensitivity analysis can be employed to predict these impacts, guiding interventions to adapt buildings to future conditions. This article explores the use of simulation to study the impact of climate change on a theoretical office building in the UK, employing a probabilistic approach. The work studies (1) appropriate performance metrics and underlying modelling assumptions, (2) sensitivity of computational results to identify key design parameters and (3) the impact of zonal resolution. The conclusions highlight the importance of assumptions in the field of electricity conversion factors, proper management of internal heat gains, and the need to use an appropriately detailed zonal resolution. © 2010 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents the development of a new building physics and energy supply systems simulation platform. It has been adapted from both existing commercial models and empirical works, but designed to provide expedient exhaustive simulation of all salient types of energy- and carbon-reducing retrofit options. These options may include any combination of behavioural measures, building fabric and equipment upgrades, improved HVAC control strategies, or novel low-carbon energy supply technologies. We provide a methodological description of the proposed model, followed by two illustrative case studies of the tool when used to investigate retrofit options of a mixed-use office building and primary school in the UK. It is not the intention of this paper, nor would it be feasible, to provide a complete engineering decomposition of the proposed model, describing all calculation processes in detail. Instead, this paper concentrates on presenting the particular engineering aspects of the model which steer away from conventional practise. © 2011 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The philosophical aspects of applying the principles of biomimicry are explored in a case study of structural design. Integrating structural engineering with services engineering can be regarded, to some extent, as taking principles from biological systems and applying them to large-scale conceptual design. The end-product discussed herein a so-called load-bearing duct, a functional naturally ventilated multi-storey office building that takes the applied loading efficiently both structurally and cost-effectively giving it the potential to be sustainable throughout its design life.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The transient natural ventilation of an enclosure through vents whose areas vary linearly with time is modelled theoretically. Both displacement and mixing flows are examined and analytical solutions developed. Predictions are presented for the ventilation of a typical office building and compared to existing constant vent area model predictions based on openings of the same average area. The predictions suggest that if the average vent areas are equal in the timedependent and constant area models, the overall time required to ventilate the enclosure is not affected. However, the rate at which heat is removed from the enclosure depends on the initial opening areas and the expansion rates/durations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple mathematical model of stack ventilation flows in multi-compartment buildings is developed with a view to providing an intuitive understanding of the physical processes governing the movement of air and heat through naturally ventilated buildings. Rules of thumb for preliminary design can be ascertained from a qualitative examination of the governing equations of flow, which elucidate the relationships between 'core' variables - flow rates, air temperatures, heat inputs and building geometry. The model is applied to an example three-storey office building with an inlet plenum and atrium. An examination of the governing equations of flow is used to predict the behaviour of steady flows and to provide a number of preliminary design suggestions. It is shown that control of ventilation flows must be shared between all ventilation openings within the building in order to minimise the disparity in flow rates between storeys, and ensure adequate fresh air supply rates for all occupants. © 2013 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article investigates how to use UK probabilistic climate-change projections (UKCP09) in rigorous building energy analysis. Two office buildings (deep plan and shallow plan) are used as case studies to demonstrate the application of UKCP09. Three different methods for reducing the computational demands are explored: statistical reduction (Finkelstein-Schafer [F-S] statistics), simplification using degree-day theory and the use of metamodels. The first method, which is based on an established technique, can be used as reference because it provides the most accurate information. However, it is necessary to automatically choose weather files based on F-S statistic by using computer programming language because thousands of weather files created from UKCP09 weather generator need to be processed. A combination of the second (degree-day theory) and third method (metamodels) requires only a relatively small number of simulation runs, but still provides valuable information to further implement the uncertainty and sensitivity analyses. The article also demonstrates how grid computing can be used to speed up the calculation for many independent EnergyPlus models by harnessing the processing power of idle desktop computers. © 2011 International Building Performance Simulation Association (IBPSA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In winter, natural ventilation can be achieved either through mixing ventilation or upward displacement ventilation (P.F. Linden, The fluid mechanics of natural ventilation, Annual Review of Fluid Mechanics 31 (1999) pp. 201-238). We show there is a significant energy saving possible by using mixing ventilation, in the case that the internal heat gains are significant, and illustrate these savings using an idealized model, which predicts that with internal heat gains of order 0.1 kW per person, mixing ventilation uses of a fraction of order 0.2-0.4 of the heat load of displacement ventilation assuming a well-insulated building. We then describe a strategy for such mixing natural ventilation in an atrium style building in which the rooms surrounding the atrium are able to vent directly to the exterior and also through the atrium to the exterior. The results are motivated by the desire to reduce the energy burden in large public buildings such as hospitals, schools or office buildings centred on atria. We illustrate a strategy for the natural mixing ventilation in order that the rooms surrounding the atrium receive both pre-heated but also sufficiently fresh air, while the central atrium zone remains warm. We test the principles with some laboratory experiments in which a model air chamber is ventilated using both mixing and displacement ventilation, and compare the energy loads in each case. We conclude with a discussion of the potential applications of the approach within the context of open plan atria type office buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new liquid crystal device structure has been developed using a vertically grown Multi-Wall Carbon NanoTube (MWCNT) as a 3D electrode structure, which allows complicated phase only hologram to be displayed using conventional liquid crystal materials. The nanotubes act as an individual electrode sites that generate an electric field profile, dictating the refractive index profile with the liquid crystal cell. Changing the electric field applied makes it possible to tune the properties to modulate the light in an ideal kinoform. A perfect 3D image can be generated by a computer generated hologram by using the diffraction of the light from the hologram pixels to create an optical wave front that appears to come from 3D object. A multilevel phase modulating device based on nematic LC's is also under progress, which will be used with the LC/CNT devices on an LCOS backplane to project a full 3D image from the kinoform.