7 resultados para next 12 months

em Cambridge University Engineering Department Publications Database


Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Recent studies in other European countries suggest that the prevalence of congenital cryptorchidism continues to increase. This study aimed to explore the prevalence and natural history of congenital cryptorchidism in a UK centre. METHODS: Between October 2001 and July 2008, 784 male infants were born in the prospective Cambridge Baby Growth Study. 742 infants were examined by trained research nurses at birth; testicular position was assessed using standard techniques. Follow-up assessments were completed at ages 3, 12, 18 and 24 months in 615, 462, 393 and 326 infants, respectively. RESULTS: The prevalence of cryptorchidism at birth was 5.9% (95% CI 4.4% to 7.9%). Congenital cryptorchidism was associated with earlier gestational age (p<0.001), lower birth weight (p<0.001), birth length (p<0.001) and shorter penile length at birth (p<0.0001) compared with other infants, but normal size after age 3 months. The prevalence of cryptorchidism declined to 2.4% at 3 months, but unexpectedly rose again to 6.7% at 12 months as a result of new cases. The cumulative incidence of "acquired cryptorchidism" by age 24 months was 7.0% and these cases had shorter penile length during infancy than other infants (p = 0.003). CONCLUSIONS: The prevalence of congenital cryptorchidism was higher than earlier estimates in UK populations. Furthermore, this study for the first time describes acquired cryptorchidism or "ascending testis" as a common entity in male infants, which is possibly associated with reduced early postnatal androgen activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Describes progress in the last 12 months which has established bag designs and fabrication techniques, giving greater confidence in the life and cost of these components. A quarter scale bag is under construction. Extensive tank testing has also established life time bending moment and mooring load envelopes, enabling hull and mooring design to proceed. A computer simulation programme has been used to check tank model results and to establish turbine and generator operating conditions. This has allowed generation and transmission component design to proceed, and suggests a high operating efficiency can be maintained with a simple control regime. Simple solutions in minor areas such as valve design and damage stability control add to the picture of steady progress in establishing the Lancaster Flexible Bag 's feasibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Product-service systems are seen by many authors to offer potential for significant sustainability benefit. Manufacturing companies are said to be essential to such a change through their influence over product performance and over the use and end-of-life stages. Yet linking these stages such that the producer is incentivized to improve the performance of later stages is still a challenge. This paper argues for placing the producer at the centre of a new arrangement: by seeking to utilize the producer's knowledge of designing and the knowledge of volume production, through creation of platforms, while cooperating closely with other actors. The paper describes three case studies that have used such an approach to design and implement new food production systems. Based on 12 months of action research observations, 10 participating organizations from the cases were studied, and the implemented solutions assessed for environmental, economic and social performance. The results demonstrate a high level of sustainability benefit is achievable using platforms and partners to design product-service systems, while highlighting that changes to production arrangements are necessary but not sufficient to improve whole life-cycle environmental performance of product-service systems, and that producers need to cooperate closely with other actors to achieve the claimed benefits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The performance of porous blocks containing three different reactive magnesia-based cements - namely magnesia alone, magnesium oxide: Portland cement (PC) in 1:1 ratio, cured in ambient conditions, and magnesia alone, cured at elevated carbon dioxide conditions, in hydrochloric acid and magnesium sulfate solution - was investigated. Different aggressive chemical solution conditions were used, to which the samples were exposed for up to 12 months and then tested for strength and microstructure. The performance was also compared with that of standard PC-based blocks. The results showed the significant resistance to chemical attack offered by magnesia, both alone and with PC blend in the porous blocks when cured under ambient carbon dioxide conditions, and confirmed the much poorer performance of blocks made from PC alone. The blocks of solely magnesia cured in elevated carbon dioxide conditions, at 20% concentration, showed slightly lower resistance to acid attack than PC; however, the resistance to sulfate attack was much higher. © 2012 Thomas Telford Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The determination of lacunar-canalicular permeability is essential to understand the mechano-transduction mechanism of bone. Murine models are widely used to investigate skeletal growth and regulation, but the value of lacunar-canalicular permeability is still unclear. To address this question, a poroelastic analysis based on nanoindentation data was used to calculate the lacunar-canalicular permeability of wild type C57BL/6 mice of 12 months. Cross-sections of three tibiae were indented using spherical fluid cell indenter tips of two sizes. Results suggest that the value of lacunar-canalicular intrinsic permeability of B6 female murine tibia is in the order of 10 -24 m2. The distribution of the values of intrinsic permeability suggests that with larger contact sizes, nanoindentation alone is capable of capturing the multi-scale permeability of bone. Multi-scale permeability of bone measured by nanoindentation will lead to a better understanding of the role of fluid flow in mechano-transduction. © 2013 American Society of Civil Engineers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The determination of lacunar-canalicular permeability is essential for understanding local fluid flow in bone, which may indicate how bone senses changes in the mechanical environment to regulate mechano-adaptation. The estimates of lacunar-canalicular permeability found in the literature vary by up to eight orders of magnitude, and age-related permeability changes have not been measured in non-osteonal mouse bone. The objective of this study is to use a poroelastic approach based on nanoindentation data to characterize lacunar-canalicular permeability in murine bone as a function of age. Nine wild type C57BL/6 mice of different ages (2, 7 and 12 months) were used. Three tibiae from each age group were embedded in epoxy resin, cut in half and indented in the longitudinal direction in the mid-cortex using two spherical fluid indenter tips (R=238 μm and 500 μm). Results suggest that the lacunar-canalicular intrinsic permeability of mouse bone decreases from 2 to 7 months, with no significant changes from 7 to 12 months. The large indenter tip imposed larger contact sizes and sampled larger ranges of permeabilities, particularly for the old bone. This age-related difference in the distribution was not seen for indents with the smaller radius tip. We conclude that the small tip effectively measured lacunar-canalicular permeability, while larger tip indents were influenced by vascular permeability. Exploring the age-related changes in permeability of bone measured by nanoindentation will lead to a better understanding of the role of fluid flow in mechano-transduction. This understanding may help indicate alterations in bone adaptation and remodeling.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The determination of lacunar-canalicular permeability is essential for understanding local fluid flow in bone, which may indicate how bone senses changes in the mechanical environment to regulate mechano-adaptation. The estimates of lacunar-canalicular permeability found in the literature vary by up to eight orders of magnitude, and age-related permeability changes have not been measured in non-osteonal mouse bone. The objective of this study is to use a poroelastic approach based on nanoindentation data to characterize lacunar-canalicular permeability in murine bone as a function of age. Nine wild type C57BL/6 mice of different ages (2, 7 and 12 months) were used. Three tibiae from each age group were embedded in epoxy resin, cut in half and indented in the longitudinal direction in the mid-cortex using two spherical fluid indenter tips (R=238 μm and 500 μm). Results suggest that the lacunar-canalicular intrinsic permeability of mouse bone decreases from 2 to 7 months, with no significant changes from 7 to 12 months. The large indenter tip imposed larger contact sizes and sampled larger ranges of permeabilities, particularly for the old bone. This age-related difference in the distribution was not seen for indents with the smaller radius tip. We conclude that the small tip effectively measured lacunar-canalicular permeability, while larger tip indents were influenced by vascular permeability. Exploring the age-related changes in permeability of bone measured by nanoindentation will lead to a better understanding of the role of fluid flow in mechano-transduction. This understanding may help indicate alterations in bone adaptation and remodeling. © 2013 Elsevier Ltd.