5 resultados para microchannels

em Cambridge University Engineering Department Publications Database


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a new way to perform hydrodynamic chromatography (HDC) for the size separation of particles based on a unique recirculating flow pattern. Pressure-driven (PF) and electro-osmotic flows (EOF) are opposed in narrow glass microchannels that expand at both ends. The resulting bidirectional flow turns into recirculating flow because of nonuniform microchannel dimensions. This hydrodynamic effect, combined with the electrokinetic migration of the particles themselves, results in a trapping phenomenon, which we have termed flow-induced electrokinetic trapping (FIET). In this paper, we exploit recirculating flow and FIET to perform a size-based separation of samples of microparticles trapped in a short separation channel using a HDC approach. Because these particles have the same charge (same zeta potential), they exhibit the same electrophoretic mobility, but they can be separated according to size in the recirculating flow. While trapped, particles have a net drift velocity toward the low-pressure end of the channel. When, because of a change in the externally applied PF or electric field, the sign of the net drift velocity reverses, particles can escape the separation channel in the direction of EOF. Larger particles exhibit a larger net drift velocity opposing EOF, so that the smaller particles escape the separation channel first. In the example presented here, a sample plug containing 2.33 and 2.82 microm polymer particles was introduced from the inlet into a 3-mm-long separation channel and trapped. Through tuning of the electric field with respect to the applied PF, the particles could be separated, with the advantage that larger particles remained trapped. The separation of particles with less than 500 nm differences in diameter was performed with an analytical resolution comparable to that of baseline separation in chromatography. When the sample was not trapped in the separation channel but located further downstream, separations could be carried out continuously rather than in batch. Smaller particles could successfully pass through the separation channel, and particles were separated by size. One of the main advantages of exploiting FIET for HDC is that this method can be applied in quite short (a few millimeters) channel geometries. This is in great contrast to examples published to date for the separation of nanoparticles in much longer micro- and nanochannels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a perspective investigation of computational modelling of blood fluid in microchannel devices as a preparation for future research on fluid-structure interaction (FSI) in biofluid mechanics. The investigation is carried out through two aspects, respectively on physical behaviours of blood flow in microchannels and appropriate methodology for modelling. The physics of blood flow is targeted to the challenges for describing blood flow in microchannels, including rheology of blood fluid, suspension features of red blood cells (RBCs), laminar hydrodynamic influence and effect of surface roughness. The analysis shows that due to the hyperelastic property of RBC and its comparable dimension with microchannels, blood fluid shows complex behaviours of two phase flow. The trajectory and migration of RBCs require accurate description of RBC deformation and interaction with plasma. Following on a discussion of modelling approaches, i.e. Eulerian method and Lagrangian method, the main stream modelling methods for multiphase flow are reviewed and their suitability to blood flow is analysed. It is concluded that the key issue for blood flow modelling is how to describe the suspended blood cells, modelled by Lagrangian method, and couple them with the based flow, modelled by Eulerian method. The multiphase flow methods are thereby classified based on the number of points required for describing a particle, as follows: (i) single-point particle methods, (ii) mutli-point particle methods, (iii) functional particle methods, and (iv) fluid particle methods. While single-point particle methods concentrate on particle dynamic movement, multipoint and functional particle methods can take into account particle mechanics and thus offer more detailed information for individual particles. Fluid particle methods provide good compromise between two phases, but require additional information for particle mechanics. For furthermore detailed description, we suggest to investigate the possibility using two domain coupling method, in which particles and base flow are modelled by two separated solvers. It is expected that this paper could clarify relevant issues in numerical modelling of blood flow in microchannels and induce some considerations for modelling blood flow using multiphase flow methods. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the design and development cycle of a 3D biochip separator and the modelling analysis of flow behaviour in the biochip microchannel features. The focus is on identifying the difference between 2D and 3D implementations as well as developing basic forms of 3D microfluidic separators. Five variants, based around the device are proposed and analysed. These include three variations of the branch channels (circular, rectangular, disc) and two variations of the main channel (solid and concentric). Ignoring the initial transient behaviour and assuming steady state flow has been established, the efficiencies of the flow between the main and side channels for the different designs are analysed and compared with regard to relevant biomicrofluidic laws or effects (bifurcation law, Fahraeus effect, cell-free phenomenon, bending channel effect and laminar flow behaviour). The modelling results identify flow features in microchannels, a constriction and bifurcations and show detailed differences in flow fields between the various designs. The manufacturing process using injection moulding for the initial base case design is also presented and discussed. The work reported here is supported as part of the UK funded 3D-MINTEGRATION project. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluids with a controllable viscosity gained a lot of interest throughout the last years. One of the advantages of these fluids is that they allow to fabricate hydraulic components such as valves with a very simple structure. Although the properties of these fluids are very interesting for microsystems, their applicability is limited at microscale since the particles suspended in these fluids tend to obstruct microchannels. This paper investigates the applicability of electrorheologic Liquid Crystals (LCs) in microsystems. Since LC's do not contain suspended particles, they show intrinsic advantages over classic rheologic active fluids in microapplications. As a matter of fact, LC molecules are usually only a few nanometers long, and therefore, they can probably be used in systems with sub-micrometer channels or other nanoscale applications. This paper presents a novel model describing the electrorheologic behavior of these nanoscale molecules. This model is used to simulate a microvalve controlled by LC's. By comparing measurements and simulations performed on this microvalve it is possible to prove that the model developed in this paper is very accurate. In addition, these simulations and measurements revealed other remarkable properties of LC's, such as high bandwidths and high changes in flow resistance. © 2006 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluids with controllable flow properties have gained considerable interest in the past few years. Some of these fluids such as magnetorheologic fluids are now widely applied to active dampers and valves. Although these fluids show promising properties for microsystems, their applicability is limited to the microscale since particles suspended in these fluids tend to obstruct microchannels. This paper investigates the applicability of electrorheologic liquid crystals (LCs) in microsystems. Since LCs do not contain suspended particles, they show intrinsic advantages over classic rheologic fluids in micro-applications. This paper presents a novel physical model that describes the static and the dynamic behaviour of electrorheologic LCs. The developed model is validated by comparing simulations and measurements performed on a rectangular microchannel. This assessment shows that the model presented in this paper is able to simulate both static and dynamic properties accurately. Therefore, this model is useful for the understanding, simulation and optimization of devices using LCs as electrorheological fluid. In addition, measurements performed in this paper reveal remarkable properties of LCs, such as high bandwidths and high changes in flow resistance. © 2006 IOP Publishing Ltd.