11 resultados para metabolic cost of ventilation
em Cambridge University Engineering Department Publications Database
Resumo:
Purpose - The purpose of this paper is to develop a framework of total acquisition cost of overseas outsourcing/sourcing in manufacturing industry. This framework contains categorized cost items that may occur during the overseas outsourcing/sourcing process. The framework was tested by a case study to establish both its feasibility and usability. Design/methodology/approach - First, interviews were carried out with practitioners who have the experience of overseas outsourcing/sourcing in order to obtain inputs from industry. The framework was then built up based on combined inputs from literature and from practitioners. Finally, the framework was tested by a case study in a multinational high-tech manufacturer to establish both its feasibility and usability. Findings - A practical barrier for implementing this framework is shortage of information. The predictability of the cost items in the framework varies. How to deal with the trade off between accuracy and applicability is a problem needed to be solved in the future research. Originality/value - There are always limitations to the generalizations that can be made from just one case. However, despite these limitations, this case study is believed to have shown the general requirement of modeling the uncertainty and dealing with the dilemma between accuracy and applicability in practice. © Emerald Group Publishing Limited.
Resumo:
We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.