13 resultados para low density lipoprotein receptor related protein

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report weaknesses in two algebraic constructions of low-density parity-check codes based on expander graphs. The Margulis construction gives a code with near-codewords, which cause problems for the sum-product decoder; The Ramanujan-Margulis construction gives a code with low-weight codewords, which produce an error-floor. © 2004 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate how sensitive Gallager's codes are, when decoded by the sum-product algorithm, to the assumed noise level. We have found a remarkably simple function that fits the empirical results as a function of the actual noise level at both high and low noise levels. © 2004 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate how sensitive Gallager's codes are, when decoded by the sum-product algorithm, to the assumed noise level. We have found a remarkably simple function that fits the empirical results as a function of the actual noise level at both high and low noise levels. ©2003 Published by Elsevier Science B. V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report weaknesses in two algebraic constructions of low-density parity-check codes based on expander graphs. The Margulis construction gives a code with near-codewords, which cause problems for the sum-product decoder; The Ramanujan-Margulis construction gives a code with low-weight codewords, which produce an error-floor. ©2003 Published by Elsevier Science B. V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A highly sensitive nonenzymatic amperometric glucose sensor was fabricated by using Ni nanoparticles homogeneously dispersed within and on the top of a vertically aligned CNT forest (CNT/Ni nanocomposite sensor), which was directly grown on a Si/SiO2 substrate. The surface morphology and elemental analysis were characterized using scanning electron microscopy and energy dispersive spectroscopy, respectively. Cyclic voltammetry and chronoamperometry were used to evaluate the catalytic activities of CNT/Ni electrode. The CNT/Ni nanocomposite sensor exhibited a great enhancement of anodic peak current after adding 5 mM glucose in alkaline solution. The sensor can also be applied to the quantification of glucose content with a linear range covering from 5 μM to 7 mM, a high sensitivity of 1433 μA mM-1 cm-2, and a low detection limit of 2 μM. The CNT/Ni nanocomposite sensor exhibits good reproducibility and long-term stability, moreover, it was also relatively insensitive to commonly interfering species, such as uric acid, ascorbic acid, acetaminophen, sucrose and d-fructose. © 2013 Elsevier B.V.