In this paper, a novel approach to Petri net modeling of programmable logic controller (PLC) programs is presented. The modeling approach is a simple extension of elementary net systems, and a graphical design tool that supports the use of this modeling approach is provided. A key characteristic of the model is that the binary sensory inputs and binary actuation outputs of the PLC are explicitly represented. This leads to the following two improvements: outputs are unambiguous, and interaction patterns are more clearly represented in the graphical form. The use of this modeling approach produces programs that are simple, lightweight, and portable. The approach is demonstrated by applying it to the development of a control module for a MonTech Positioning Station. © 2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon nanotube (CNT) based nano electromechanical system (NEMS) were developed to apply to the logic and the memory circuit. The electrical 'on-off' behavior induced by the mechanical movements of CNTs can promise low power consumption in circuit with very low level leakage current. Additionally, the unique vertical structure of nanotubes allows high integration density for devices. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive nonenzymatic amperometric glucose sensor was fabricated by using Ni nanoparticles homogeneously dispersed within and on the top of a vertically aligned CNT forest (CNT/Ni nanocomposite sensor), which was directly grown on a Si/SiO2 substrate. The surface morphology and elemental analysis were characterized using scanning electron microscopy and energy dispersive spectroscopy, respectively. Cyclic voltammetry and chronoamperometry were used to evaluate the catalytic activities of CNT/Ni electrode. The CNT/Ni nanocomposite sensor exhibited a great enhancement of anodic peak current after adding 5 mM glucose in alkaline solution. The sensor can also be applied to the quantification of glucose content with a linear range covering from 5 μM to 7 mM, a high sensitivity of 1433 μA mM-1 cm-2, and a low detection limit of 2 μM. The CNT/Ni nanocomposite sensor exhibits good reproducibility and long-term stability, moreover, it was also relatively insensitive to commonly interfering species, such as uric acid, ascorbic acid, acetaminophen, sucrose and d-fructose. © 2013 Elsevier B.V.