22 resultados para enivornmental scan
em Cambridge University Engineering Department Publications Database
Resumo:
OVERVIEW: Kodak European Research (KER) developed a strategy for technology intelligence based on a theoretical model developed by Kerr et al. (2006). KER scouts designed and implemented a four-step approach to identify relevant technologies and research centers across Europe, Africa and the Middle East. The approach provides clear guidance for integrating web searches, scouting trips, networking and interactions with intermediaries. KER's example illustrates how companies can organize themselves to look outside corporate boundaries in search of technologies relevant for their business. The approach may be useful to those in other companies who have been asked to start a technology intelligence activity. © 2010 Industrial Research Institute, Inc.
Resumo:
A novel method for on-line topographic analysis of rough surfaces in the SEM has been investigated. It utilises a digital minicomputer configured to act as a programmable scan generator and automatic focusing unit. The computer is coupled to the microscope through digital-to-analogue converters which enable it to generate ramp waveforms allowing the beam to be scanned over a small sub-region of the field under program control. A further digital-to-analogue converter regulates the current supply to the objective lens of the microscope. The video signal is sampled by means of an analogue-to-digital converter and the resultant binary code stored in the computer's memory as an array of numbers describing relative image intensity. Computations based on the intensity gradient of the image allow the objective lens current to be found for the in-focus condition, which may be related to the working distance through a previous calibration experiment. The sensitivity of the method for detecting small height changes is theoretically of the order of 1 μm. In practice the operator specifies features of interest by means of a mobile spot cursor injected into the SEM display screen, or he may scan the specimen at sub-regions corresponding to pre-determined points on a regular grid defined by him. The operation then proceeds under program control. | A novel method for on-line topographic analysis of rough surfaces in the SEM has been investigated. It utilizes a digital minicomputer configured to act as a programmable scan generator and automatic focusing unit. A further digital-to-analog converter regulates the current supply to the objective lens of the microscope. The video signal is sampled by means of an analog-to-digital converter and the resultant binary code stored in the computer's memory as an array of numbers describing relative image intensity. The sensitivity of the method for detecting small height changes is theroretically of the order of 1 mu m.
Resumo:
A digital minicomputer has been interfaced with a scanning electron microscope, and programmed to control the excitations of the objective lens and the stigmator of the microscope. The electron beam is scanned by a digital scan generator and the digitised video signal is used for computations. To focus the microscope, a parameter related to the 'sharpness' of the image is maximised, and to set the stigmator, the directional information in the above- and below-focus images is used. | A digital minicomputer has been interfaced with a scanning electron microscope, and programmed to control the excitations of the objective lens and the stigmator of the microscope. The electron beam is scanned by a digital scan generator and the digitized video signal is used for computations. To focus the microscope, a parameter related to the 'sharpness' of the image is maximized, and to set the stigmator, the directional information in the above and below-focus images is used.
Resumo:
A novel technique for automated topographical analysis in the SEM has been investigated. It utilizes a 16-bit minicomputer arranged to act as an automatic focusing unit. The computer is coupled to the objective lens of the microscope, by means of a digital to analogue converter, and may regulate the excitation of the lens under program control. Further digital-to-analogue converters allow the computer to act as a programmable scan generator by applying ramp waveforms to the scan amplifiers, permitting the beam to be swept over a small sub-region of the field of interest. The video signal is sampled and applied to an analogue-to-digital converter; the resultant binary numbers are stored in computer memory as an array of values representing relative image intensities within a subregion. A differencing algorithm applied to the collected data allows the level of objective lens excitation to be found at which the sharpness of the image is optimized, and the excitation may be related to the working distance for that subregion through a previous calibration experiment. The sensitivity of the method for detecting small height changes is theoretically of the order of 1 μm.
Resumo:
Melt-textured YBCO samples processed with added Y2O3 and depleted uranium oxide (DU) contain nano-particles, which have been identified previously as Y2Ba4CuUOx (U-411). This phase has a cubic unit cell, which is clearly distinct from the orthorhombic Y-123 and Y-211 phases within the YBCO system. In samples with a high amount of DU addition (0.8 wt-% DU), U-2411 particles have sizes between 200 nm and several νm, so identification of the Kikuchi patterns of this phase becomes possible. Together with a parallel EDX analysis, the particles embedded in the Y-123 matrix can be identified unambiguously. In this way, a three-phase EBSD scan becomes possible, allowing also the identification of nanometre-sized particles in the sample microstructure. © 2006 IOP Publishing Ltd.
Resumo:
The industrial landscape is becoming increasingly complex and dynamic, with innovative technologies stimulating the emergence of new industries and business models. This paper presents a preliminary framework for mapping industrial emergence, based on roadmapping principles, in order to understand the nature and characteristics of such phenomena. The focus at this stage is on historical examples of industrial emergence, with the preliminary framework based on observations from 20 'quick scan' maps, one of which is used to illustrate the framework. The learning from these historical cases, combined with further industrial consultation and literature review, will be used to develop practical methods for strategy and policy application. The paper concludes by summarising key learning points and further work needed to achieve these outcomes. © 2009 PICMET.
Resumo:
Ultrasound elastography tracks tissue displacements under small levels of compression to obtain images of strain, a mechanical property useful in the detection and characterization of pathology. Due to the nature of ultrasound beamforming, only tissue displacements in the direction of beam propagation, referred to as 'axial', are measured to high quality, although an ability to measure other components of tissue displacement is desired to more fully characterize the mechanical behavior of tissue. Previous studies have used multiple one-dimensional (1D) angled axial displacements tracked from steered ultrasound beams to reconstruct improved quality trans-axial displacements within the scan plane ('lateral'). We show that two-dimensional (2D) displacement tracking is not possible with unmodified electronically-steered ultrasound data, and present a method of reshaping frames of steered ultrasound data to retain axial-lateral orthogonality, which permits 2D displacement tracking. Simulated and experimental ultrasound data are used to compare changes in image quality of lateral displacements reconstructed using 1D and 2D tracked steered axial and steered lateral data. Reconstructed lateral displacement image quality generally improves with the use of 2D displacement tracking at each steering angle, relative to axial tracking alone, particularly at high levels of compression. Due to the influence of tracking noise, unsteered lateral displacements exhibit greater accuracy than axial-based reconstructions at high levels of applied strain. © 2011 SPIE.