5 resultados para control configuration

em Cambridge University Engineering Department Publications Database


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three-dimensional bumps have been developed and investigated, aiming at the two major objectives of shock-wave / boundary-layer interaction control, i.e. drag reduction and suppression of separation, simultaneously. An experimental investigation has been conducted for a default rounded bump in channel now at University of Cambridge and a computational study has been performed for a spanwise series of rounded bumps mounted on a transonic aerofoil at University of Stuttgart. Observed in both cases are wave drag reduction owing to A-shock structures produced by three-dimensional surface bumps and mild control effects on the boundary layer. The effects of rough surface and tall extension have been investigated as well as several geometric variations and multiple bump configurations. A double configuration of narrow rounded bumps has been found to best perform amongst the tested, considerably reducing wave drag through a well-established A-shock structure with little viscous penalty and thus achieving substantial overall drag reduction. Counter-rotating streamwise vortex pairs have been produced by some configurations as a result of local flow separation, but they have been observed to be confined in relatively narrow wake regions, expected to be beneficial in suppressing large-scale separation under off-design condition despite increase of viscous drag. On the whole a large potential of three-dimensional control with discrete rounded bumps has been demonstrated both experimentally and numerically, and experimental investigation of bumps fitted on a transonic aerofoil or wing is suggested toward practical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focuses on simplifying and easing the integration of a new machine into an existing conventional hierarchical manufacturing system. Based on a distributed manufacturing paradigm, it proposes the functions and interfaces that a new machine and an existing manufacturing system should possess so that ready and simple configuration of additional machines can be achieved. The configuration process is intended to include, not only mechanical and electrical interfaces, but also decision system interfaces (such as planning, scheduling, and shop-floor control). Preliminary laboratory experiments to compare the reconfigurability resulting from a conventional integration method and the proposed distributed method are presented and discussed. © 2007 ISAM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate whether vortex generators can be an effective form of passive flow control an experimental investigation has been conducted in a small-scale wind tunnel. With specific emphasis on supersonic inlet applications flow separation was initiated using a combined terminal shock wave and subsonic diffuser: a configuration that has been developed as a part of a program to produce a more inlet-relevant flowfield in a small-scale wind tunnel than previous studies. When flow control was initially introduced little overall flow improvement was obtained as the losses tended to be redistributed instead of removed. It became apparent that there existed a strong coupling between the center-span flow and the corner flows. As a consequence, only when flow control was applied to both the corner flows and center-span flow was a significant flow improvement obtained. When corner suction and center-span vortex generators were employed in tandem separation was much reduced and wall-pressure and stagnation pressure were notably improved. As a result, when applied appropriately, it is thought that vortex generators do have the potential to reduce the dependence on boundary-layer bleed for the purpose of separation suppression. Copyright © 2012 by Neil Titchener and Holger Babinsky. Published by the American Institute of Aeronautics and Astronautics, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Delivering acceptable low end torque and good transient response is a significant challenge for all turbocharged engines. As downsized gasoline engines and Diesel engines make up a larger and larger proportion of the light-duty engines entering the market, the issue takes on greater significance. Several schemes have been proposed to improve torque response in highly boosted engines, including the use of electrical assist turbochargers and compressed air assist. In this paper we examine these methods with respect to their effectiveness in improving transient response and their relative performance along with some of the practical considerations for real world application. Results shown in this paper are from 1-D simulations using the Ricardo WAVE software package. The simulation model is based on a production light-duty Diesel engine modified to allow the introduction of compressed air at various points in the air-path as well as direct torque application to the turbocharger shaft (such as might be available from an electrical assist turbocharger). Whilst the 1-D simulation software provides a suitable environment for investigating the various boost assistance options, the overall air path performance also depends upon the control system. The introduction of boost assistance complicates the control in two significant ways: the system may run into constraints (such as compressor surge) that are not encountered in normal operation and the assistance introduces an additional control input. Production engine controllers are usually based on gain-scheduled PID control and extensive calibration. For this study, the non-linear nature of the engine together with the multiple configurations considered and the slower than real-time execution of 1-D models makes such an approach time consuming. Moreover, an ad-hoc approach would leave some doubt as to the fairness of comparisons between the different boost-assist options. Model Predictive Control has been shown to offer a convenient approach to controlling the 1-D simulations in a close to optimal manner for a typical Diesel VGT-EGR air path configuration. We show that the same technique can be applied to all the considered assistance methods with only modest calibration effort required. Copyright © 2012 SAE International.