35 resultados para Very-Low Mass

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Loose saturated sandy soils may undergo liquefaction under cyclic loading, generating positive excess pore pressures due to their contractile nature and inability to dissipate pore pressures rapidly during earthquake loading. These liquefied soils have a near-zero effective stress state, and hence have very low strength and stiffness, causing severe damage to structures founded upon them. The duration for which this near-zero effective stress state persists is a function of the rate of reconsolidation of the liquefied soil, which in turn is a function of the permeability and stiffness of the soil at this very low effective stress. Existing literature based on observation of physical model tests suggests that the consolidation coefficient C v associated with this reconsolidation of liquefied sand is significantly lower than that of the same soil at moderate stress levels. In this paper, the results of a series of novel fluidisation tests in which permeability k and coefficient of consolidation C v were independently measured will be presented. These results allow calculation of the variation of stiffness E 0 and permeability k with effective stress. It is shown that while permeability increases markedly at very low effective stresses, the simultaneous drop in stiffness measured results in a decrease in consolidation coefficient and hence an increase in the duration for which the soil remains liquefied.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An electron cyclotron wave resonant methane plasma discharge was used for the high rate deposition of hydrogenated amorphous carbon (a-C:H). Deposition rates of up to ∼400 Å/min were obtained over substrates up to 2.5 in. in diameter with a film thickness uniformity of ∼±10%. The deposited films were characterised in terms of their mass density, sp3 and hydrogen contents, C-H bonding, intrinsic stress, scratch resistance and friction properties. The deposited films possessed an average sp3 content, mass density and refractive index of ∼58%, 1.76 g/cm3 and 2.035 respectively.Mechanical characterisation indicated that the films possessed very low steady-state coefficients of friction (ca. 0.06) and a moderate shear strength of ∼141 MPa. Nano-indentation measurements also indicated a hardness and elastic modulus of ∼16.1 and 160 GPa respectively. The critical loads required to induce coating failure were also observed to increase with ion energy as a consequence of the increase in degree of ion mixing at the interface. Furthermore, coating failure under scratch test conditions was observed to take place via fracture within the silicon substrate itself, rather than either in the coating or at the film/substrate interface. © 2003 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Reliable estimates for the maximum available uplift resistance from the backfill soil are essential to prevent upheaval buckling of buried pipelines. The current design code DNV RP F110 does not offer guidance on how to predict the uplift resistance when the cover:pipe diameter (H/D) ratio is less than 2. Hence the current industry practice is to discount the shear contribution from uplift resitance for design scenarios with H/D ratios less than 1. The necessity of this extra conservatism is assessed through a series of full-scale and centrifuge tests, 21 in total, at the Schofield Centre, University of Cambridge. Backfill types include saturated loose sand, saturated dense sand and dry gravel. Data revealed that the Vertical Slip Surface Model remains applicable for design scenarios in loose sand, dense sand and gravel with H/D ratios less than 1, and that there is no evidence that the contribution from shear should be ignored at these low H/D ratios. For uplift events in gravel, the shear component seems reliable if the cover is more than 1-2 times the average particle size (D50), and more research effort is currenty being carried out to verify this conclusion. Strain analysis from the Particle Image Velocimetry (PIV) technique proves that the Vertical Slip Surface Model is a good representation of the true uplift deformation mechanism in loose sand at H/D ratios between 0.5 and 3.5. At very low H/D ratios (H/D < 0.5), the deformation mechanism is more wedge-like, but the increased contribution from soil weight is likely to be compensated by the reduced shear contributions. Hence the design equation based on the Vertical Slip Surface Model still produces good estimates for the maximum available uplift resistance. The evolution of shear strain field from PIV analysis provides useful insight into how uplift resistance is mobilized as the uplift event progresses. Copyright 2010, Offshore Technology Conference.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Using transonic blowdown windtunnel experiments, the 2D unsteady shock motion on a NACA0012 aerofoil is examined at various frequencies typical for helicopter blades in forward flight. The aerofoil is subjected to freestream velocities oscillating periodically between M = 0.66 and M = 0.77. Unsteady pressure traces and schlieren images are analyzed over a range of low reduced frequencies to provide information on shock location and strength throughout the cycle. Unsteady effects were noticeable even at very low reduced frequencies (down to O(0.01). However, through the range of frequencies investigated, and within experimental error, the unsteady shock location showed no discernible lag compared to the quasi-steady behaviour. On the other hand, significant variations were observed in shock strengths with the upstream running part of the cycle (decreasing Mach number) displaying considerably stronger shocks than during the accelerating part of the cycle. It could be shown that this variation in shock strength is primarily caused by the shock motion modifying the relative shock Mach number. As a result is was possible to use the quasi-steady results to predict the unsteady shock behaviour at the frequencies investigated here (below 0(0.1)).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Using transonic blowdown windtunnel experiments, the 2D unsteady shock motion on a NACA0012 aerofoil is examined at various frequencies typical for helicopter blades in forward flight. The aerofoil is subjected to freestream velocities oscillating periodically between M = 0.66 and M = 0.77. Unsteady pressure traces and schlieren images are analyzed over a range of low reduced frequencies to provide information on shock location and strength throughout the cycle. Unsteady effects were noticeable even at very low reduced frequencies (down to O(0.01). However, through the range of frequencies investigated, and within experimental error, the unsteady shock location showed no discernible lag compared to the quasi-steady behaviour. On the other hand, significant variations were observed in shock strengths with the upstream running part of the cycle (decreasing Mach number) displaying considerably stronger shocks than during the accelerating part of the cycle. It could be shown that this variation in shock strength is primarily caused by the shock motion modifying the relative shock Mach number. As a result is was possible to use the quasi-steady results to predict the unsteady shock behaviour at the frequencies investigated here (below 0(0.1)).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Zinc oxide (ZnO) thin films were deposited at high rates ( > 50 nm min-1) using a unique technique known as high target utilisation sputtering (HiTUS). The films obtained possess good crystallographic orientation, low surface roughness, very low stress and excellent piezoelectric properties. We have utilised the films to develop highly sensitive biosensors based on thickness longitudinal mode (TLM) thin film bulk acoustic resonators (FBARs). The FBARs have the fundamental TLM at a frequency near 1.5 GHz and quality factor Q higher than 1,000, which is one of the largest values ever reported for ZnO-based FBARs. Bovine Serum Albumin (BSA) solutions with different concentrations were placed on the top of different sets of identical FBARs and their responses to mass-loading from physically adsorbed protein coatings were investigated. These resonators demonstrated a high sensitivity and thus have a great potential as gravimetric sensors for biomedical applications. © 2011 Inderscience Enterprises Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Film bulk acoustic resonator (FBAR) devices with carbon nanotube (CNT) electrodes directly grown on a ZnO film by thermal chemical vapor deposition have been fabricated. CNT electrodes possess a very low density and high acoustic impedance, which reduces the intrinsic mass loading effect resulting from the electrodes' weight and better confines the longitudinal acoustic standing waves inside the resonator, in turn providing a resonator with a higher quality factor. The influence of the CNTs on the frequency response of the FBAR devices was studied by comparing two identical sets of devices; one set comprised FBARs fabricated with chromium/ gold bilayer electrodes, and the second set comprised FBARs fabricated with CNT electrodes. It was found that the CNTs had a significant effect on attenuating traveling waves at the surface of the FBARs' membranes because of their high elastic stiffness. Three-dimensional finite element analysis of the devices fabricated was carried out, and the numerical simulations were consistent with the experimental results obtained. © 2011 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We study the behavior of channel capacity when a one-bit quantizer is employed at the output of the discrete-time average-power-limited Gaussian channel. We focus on the low signal-to-noise ratio regime, where communication at very low spectral efficiencies takes place, as in Spread-Spectrum and Ultra-Wideband communications. It is well known that, in this regime, a symmetric one-bit quantizer reduces capacity by 2/π, which translates to a power loss of approximately two decibels. Here we show that if an asymmetric one-bit quantizer is employed, and if asymmetric signal constellations are used, then these two decibels can be recovered in full. © 2011 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes the conceptual ideas, the theoretical validation, the laboratory testing and the field trials of a recently patented fuel-air mixing device for use in high-pressure ratio, low emissions, gaseous-fueled gas turbines. By making the fuel-air mixing process insensitive to pressure fluctuations in the combustion chamber, it is possible to avoid the common problem of positive feedback between mixture strength and the unsteady combustion process. More specifically, a mixing duct has been designed such that fuel-air ratio fluctuations over a wide range of frequencies can be damped out by passive design means. By scaling the design in such a way that the range of damped frequencies covers the frequency spectrum of the acoustic modes in the combustor, the instability mechanism can be removed. After systematic development, this design philosophy was successfully applied to a 35:1 pressure ratio aeroderivative gas turbine yielding very low noise levels and very competitive NOx and CO measurements. The development of the new premixer is described from conceptual origins through analytic and CFD evaluation to laboratory testing and final field trials. Also included in this paper are comments about the practical issues of mixing, flashback resistance and autoignition.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We design, optimize and demonstrate a highly efficient carrier-depletion silicon Mach-Zehnder modulator with very low VπL of ~0.2Vcm. Design consideration, fabrication process and experimental results will be presented. © OSA 2013.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this letter, the uniform lying helix (ULH) liquid crystal texture, required for the flexoelectro-optic effect, is polymer stabilized by the addition of a small percentage of reactive mesogen to a high-tilt-angle (φ>60°) bimesogenic chiral nematic host. The electro-optic response is measured for a range of reactive mesogen concentration mixtures, and compared to the large-tilt-angle switch of the pure chiral nematic mixture. The optimum concentration of reactive mesogen, which is found to provide ample stabilization of the texture with minimal impact on the electro-optic response, is found to be approximately 3%. Our results indicate that polymer stabilization of the ULH texture using a very low concentration of reactive mesogen is a reliable way of ruggedizing flexoelectro-optic devices without interfering significantly with the electro-optics of the effect, negating the need for complicated surface alignment patterns or surface-only polymerization. The polymer stabilization is shown to reduce the temperature dependence of the flexoelectro-optic response due to "pinning" of the chiral nematic helical pitch. This is a restriction of the characteristic thermochromic behavior of the chiral nematic. Furthermore, selection of the temperature at which the sample is ultraviolet cured allows the tilt angle to be optimized for the entire chiral nematic temperature range. The response time, however, remains more sensitive to operating temperature than curing temperature. This allows the sample to be cured at low temperature and operated at high temperature, providing simultaneous optimization of these two previously antagonistic performance aspects. © 2006 American Institute of Physics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes coupled-effect simulations of smart micro gas-sensors based on standard BiCMOS technology. The smart sensor features very low power consumption, high sensitivity and potential low fabrication cost achieved through full CMOS integration. For the first time the micro heaters are made of active CMOS elements (i.e. MOSFET transistors) and embedded in a thin SOI membrane consisting of Si and SiO2 thin layers. Micro gas-sensors such as chemoresistive, microcalorimeteric and Pd/polymer gate FET sensors can be made using this technology. Full numerical analyses including 3D electro-thermo-mechanical simulations, in particular stress and deflection studies on the SOI membranes are presented. The transducer circuit design and the post-CMOS fabrication process, which includes single sided back-etching, are also reported.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We measure the effects of phonon confinement on the Raman spectra of silicon nanowires. We show how previous spectra were inconsistent with phonon confinement, but were due to intense local heating caused by the laser. This is peculiar to nanostructures, and would require orders of magnitude more power in bulk Si. By working at very low laser powers, we identify the contribution of pure confinement typical of quantum wires.