15 resultados para Vertical displacement measurement
em Cambridge University Engineering Department Publications Database
Resumo:
With recent developments in carbon-based electronics, it is imperative to understand the interplay between the morphology and electronic structure in graphene and graphite. We demonstrate controlled and repeatable vertical displacement of the top graphene layer from the substrate mediated by the scanning tunneling microscopy (STM) tip-sample interaction, manifested at the atomic level as well as over superlattices spanning several tens of nanometers. Besides the full-displacement, we observed the first half-displacement of the surface graphene layer, confirming that a reduced coupling rather than a change in lateral layer stacking is responsible for the triangular/honeycomb atomic lattice transition phenomenon, clearing the controversy surrounding it. Furthermore, an atomic scale mechanical stress at a grain boundary in graphite, resulting in the localization of states near the Fermi energy, is revealed through voltage-dependent imaging. A method of producing graphene nanoribbons based on the manipulation capabilities of the STM is also implemented.
Resumo:
PiP software is a powerful computational tool for calculating vibration from underground railways and for assessing the performance of vibration countermeasures. The software has a user-friendly interface and it uses the state-of-the-art techniques to perform quick calculations for the problem. The software employs a model of a slab track coupled to a circular tunnel embedded in the ground. The software calculates the Power Spectral Density (PSD) of the vertical displacement at any selected point in the soil. Excitation is assumed to be due to an infinitely-long train moving on a slab-track supported at the tunnel bed. The PSD is calculated for a roughness excitation of a unit value (i.e. "white noise"). The software also calculates the Insertion Gain (IG) which is the ratio between the PSD displacement after and before changing parameters of the track, tunnel or soil. Version 4 of the software accounts for important developments of the numerical model. The tunnel wall is modelled as a thick shell (using the elastic continuum theory) rather than a thin shell. More importantly, the numerical model accounts now for a tunnel embedded in a half space rather than a full space as done in the previous versions. The software can now be used to calculate vibration due to a number of typical PSD roughnesses for rails in good, average and bad conditions.
Resumo:
We present an in-depth study of the myriad atomically resolved patterns observed on graphite using the scanning tunnelling microscope (STM) over the past three decades. Through the use of highly resolved atomic resolution images, we demonstrate how the interactions between the different graphene layers comprising graphite affect the local surface atomic charge density and its resulting symmetry orientation, with particular emphasis on interactions that are thermodynamically unstable. Moreover, the interlayer graphene coupling is controlled experimentally by varying the tip-surface interaction, leading to associated changes in the atomic patterns. The images are corroborated by first-principles calculations, further validating our claim that surface graphene displacement, coming both from lateral and vertical displacement of the top graphene layer, forms the basis of the rich variety of atomic patterns observed in STM experiments on graphite.
Resumo:
The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.
Resumo:
We investigate the steady state natural ventilation of a room heated at the base and consisting of two vents at different levels. We explore how the air flow rate and internal temperature relative to the exterior vary as a function of the vent areas, position of the vents and heat load in order to establish appropriate ventilation strategies for a room. When the room is heated by a distributed source, the room becomes well mixed and the steady state ventilation rate depends on the heating rate, the area of the vents and the distance between the lower and upper level vents. However, when the room is heated by a localised source the room becomes stratified. If the effective ventilation area is sufficiently large, then the interface separating the two layers lies above the inlet vent and the lower layer is comprised of ambient fluid. In this case the upper layer is warmer than in the well mixed case and the ventilation rate is smaller. However, if the effective area for ventilation is sufficiently small, then the interface separating the two layers lies below the inlet vent and the lower layer is comprised of warm fluid which originates as the cold incoming fluid mixes during descent from the vent through the upper layer. In this case both the ventilation rate and the upper layer temperature are the same as in the case of a distributed heat load. As the vertical separation between lower and upper level vents decreases, then the temperature difference between the layers falls to zero and the room becomes approximately well mixed. These findings suggest how the appropriate ventilation strategy for a room can be varied depending on the exterior temperature, with mixing ventilation more suitable for winter conditions and displacement ventilation for warmer external temperatures.
Resumo:
Saturated sands particularly at low relative density commonly exhibit rises in excess pore pressure when subjected to earthquake loading. The excess pore pressure can approach a maximum value, limited by the initial vertical effective stress. After the completion of earthquake shaking, these excess pore pressures dissipate according to the consolidation equation, which can be solved to produce a Fourier series solution. It will be shown by manipulation of this Fourier series that excess pore pressure traces provide a method for back-calculation of coefficient of consolidation Cv. This method is validated against dissipation curves generated using known values of C v and seen to be more accurate in the middle of the layer. The method is then applied to data recorded in centrifuge tests to evaluate Cv throughout the reconsolidation process following liquefaction conditions. C v is seen to fit better as a function of excess pore pressure ratio than effective stress for the stress levels considered. For the soil investigated, Cv is about three times smaller at excess pore pressure ratio of 0.9 compared to excess pore pressure ratio of 0. Copyright © 1996-2011 ASTM.
Resumo:
Gas turbine engine performance requires effective and reliable internal cooling over the duty cycle of the engine. Life predictions for rotating components subject to the main gas path temperatures are vital. This demands increased precision in the specification of the internal air system flows which provide turbine stator well cooling and sealing. This in turn requires detailed knowledge of the flow rates through rim seals and interstage labyrinth seals. Knowledge of seal movement and clearances at operating temperatures is of great importance when prescribing these flows. A test facility has been developed at the University of Sussex, incorporating a two stage turbine rated at 400 kW with an individual stage pressure ratio of 1.7:1. The mechanical design of the test facility allows internal cooling geometry to be rapidly re-configured, while cooling flow rates of between 0.71 CW, ENT and 1.46 C W, ENT, may be set to allow ingress or egress dominated cavity flows. The main annulus and cavity conditions correspond to in cavity rotational Reynolds numbers of 1.71×106< Reφ <1.93×106. Displacement sensors have been used to establish hot running seal clearances over a range of stator well flow conditions, allowing realistic flow rates to be calculated. Additionally, gas seeding techniques have been developed, where stator well and main annulus flow interactions are evaluated by measuring changes in gas concentration. Experiments have been performed which allow rim seal and re-ingestion flows to be quantified. It will be shown that this work develops the measurement of stator well cooling flows and provides data suitable for the validation of improved thermo-mechanical and CFD codes, beneficial to the engine design process. Copyright © 2011 by Rolls-Royce plc.