24 resultados para Systems evaluation

em Cambridge University Engineering Department Publications Database


Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a systematic, practical approach to developing risk prediction systems, suitable for use with large databases of medical information. An important part of this approach is a novel feature selection algorithm which uses the area under the receiver operating characteristic (ROC) curve to measure the expected discriminative power of different sets of predictor variables. We describe this algorithm and use it to select variables to predict risk of a specific adverse pregnancy outcome: failure to progress in labour. Neural network, logistic regression and hierarchical Bayesian risk prediction models are constructed, all of which achieve close to the limit of performance attainable on this prediction task. We show that better prediction performance requires more discriminative clinical information rather than improved modelling techniques. It is also shown that better diagnostic criteria in clinical records would greatly assist the development of systems to predict risk in pregnancy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes a framework for evaluation of spoken dialogue systems. Typically, evaluation of dialogue systems is performed in a controlled test environment with carefully selected and instructed users. However, this approach is very demanding. An alternative is to recruit a large group of users who evaluate the dialogue systems in a remote setting under virtually no supervision. Crowdsourcing technology, for example Amazon Mechanical Turk (AMT), provides an efficient way of recruiting subjects. This paper describes an evaluation framework for spoken dialogue systems using AMT users and compares the obtained results with a recent trial in which the systems were tested by locally recruited users. The results suggest that the use of crowdsourcing technology is feasible and it can provide reliable results. Copyright © 2011 ISCA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present the development of a drug-loaded triple-layer platform consisting of thin film biodegradable polymers, in a properly designed form for the desired gradual degradation. Poly(dl-lactide-co-glycolide) (PLGA (65:35), PLGA (75:25)) and polycaprolactone (PCL) were grown by spin coating technique, to synthesize the platforms with the order PCL/PLGA (75:25)/PLGA (65:35) that determine their degradation rates. The outer PLGA (65:35) layer was loaded with dipyridamole, an antiplatelet drug. Spectroscopic ellipsometry (SE) in the Vis-far UV range was used to determine the nanostructure, as well as the content of the incorporated drug in the as-grown platforms. In situ and real-time SE measurements were carried out using a liquid cell for the dynamic evaluation of the fibrinogen and albumin protein adsorption processes. Atomic force microscopy studies justified the SE results concerning the nanopores formation in the polymeric platforms, and the dominant adsorption mechanisms of the proteins, which were defined by the drug incorporation in the platforms. © 2013 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper experimentally demonstrates that, for two representative indoor distributed antenna system (DAS) scenarios, existing radio-over-fiber (RoF) DAS installations can enhance the capacity advantages of broadband 3 × 3 multiple-input-multiple-output (MIMO) radio services without requiring additional fibers or multiplexing schemes. This is true for both single-and multiple-user cases with a single base station and multiple base stations. First, a theoretical example is used to illustrate that there is a negligible improvement in signal-to-noise ratio (SNR) when using a MIMO DAS with all N spatial streams replicated at N RAUs, compared with a MIMO DAS with only one of the N streams replicated at each RAU for N ≤ 4. It is then experimentally confirmed that a 3 × 3 MIMO DAS offers improved capacity and throughput compared with a 3 × 3 MIMO collocated antenna system (CAS) for the single-user case in two typical indoor DAS scenarios, i.e., one with significant line-of-sight (LOS) propagation and the other with entirely non-line-of-sight (NLOS) propagation. The improvement in capacity is 3.2% and 4.1%, respectively. Then, experimental channel measurements confirm that there is a negligible capacity increase in the 3 × 3 configuration with three spatial streams per antenna unit over the 3 × 3 configuration with a single spatial stream per antenna unit. The former layout is observed to provide an increase of ∼1% in the median channel capacity in both the single-and multiple-user scenarios. With 20 users and three base stations, a MIMO DAS using the latter layout offers median aggregate capacities of 259 and 233 bit/s/Hz for the LOS and NLOS scenarios, respectively. It is concluded that DAS installations can further enhance the capacity offered to multiple users by multiple 3 × 3 MIMO-enabled base stations. Further, designing future DAS systems to support broadband 3 × 3 MIMO systems may not require significant upgrades to existing installations for small numbers of spatial streams. © 2013 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador: