30 resultados para Suction Bucket Foundation

em Cambridge University Engineering Department Publications Database


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The seismic design for offshore foundations is based predominantly on experience onshore. This paper describes the results of dynamic centrifuge tests performed to validate the performance of a suction caisson installed in normally consolidated clay. The main objective is to evaluate the likely plastic displacement under different shaking levels. Permanent displacement results indicate that the displacements experienced are well within the allowable movement for the foundation considered, even though a strength based design approach would consider this to be a failure. Larger earthquakes are seen to produce comparatively smaller displacements. It is concluded that the when designing for seismic loading, if some displacement is permissible then a performance-based approach allowing some displacement proves significantly less conservative than a purely strength-based design. It is also concluded that dynamic response analyses should consider the strength of soil, as this can act as a fuse against large amplitude shear waves. © 2011 Taylor & Francis Group, London.