98 resultados para Slope Mass Rating

em Cambridge University Engineering Department Publications Database


Relevância:

30.00% 30.00%

Publicador:

Resumo:

One feature of earthquake loading in regions containing sloping ground is a marked increase in accelerations at the crests of slopes. Many field cases exist where such increased accelerations were measured. The observed increase in the amount and severity of observed building damage near the edge of cliff-type topographies has been attributed to the topographic amplification. To counter this, it has been shown that anchoring the soil mass responsible for this to the rest of the stable soil mass can reduce the amount of topographic amplification. In this study, dynamic centrifuge modelling will be used to identify the region affected by topographic amplification in a model slope. The soil accelerations recorded will be compared to those measured in a comparable model treated by anchors. In addition, the tension measured in the anchors will be examined in order to better understand how the anchors are transferring the loads and mitigating these amplifications. © 2010 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel slope delay model for CMOS switch-level timing verification is presented. It differs from conventional methods in being semianalytic in character. The model assumes that all input waveforms are trapezoidal in overall shape, but that they vary in their slope. This simplification is quite reasonable and does not seriously affect precision, but it facilitates rapid solution. The model divides the stages in a switch-level circuit into two types. One corresponds to the logic gates, and the other corresponds to logic gates with pass transistors connected to their outputs. Semianalytic modeling for both cases is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single-crystal silicon resonant bulk acoustic mass sensor with a measured resolution of 125 pg cm2 is presented. The mass sensor comprises a micromachined silicon plate that is excited in the square-extensional bulk acoustic resonant mode at a frequency of 2.182 MHz, with a quality factor exceeding 106. The mass sensor has a measured mass to frequency shift sensitivity of 132 Hz cm2 μg. The resonator element is embedded in a feedback loop of an electronic amplifier to implement an oscillator with a short term frequency stability of better than 7 ppb at an operating pressure of 3.8 mTorr. © 2007 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador: