7 resultados para STABILITY RANGE

em Cambridge University Engineering Department Publications Database


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Casing grooves are known to increase the stable operating range of axial compressors. The mechanism by which this stability enhancement occurs is poorly understood. This paper develops a better understanding of the behavior of casing grooves through analysis of new data. An experimental parametric study is used to demonstrate the effect of varying the axial location of a single casing groove on the stability and efficiency of the compressor. The effect that the groove has on rotor outflow blockage, blade loading, and the near-casing flow field is then investigated using both experimental and computational methods. It is found that the interaction of the groove with the flow field is different when the groove is positioned forward or aft relative to the blade. The interaction of the groove with the flow in the tip region in both of these positions is presented in detail. Finally, the implications of these findings for the design of casing grooves of different depths are discussed. © 2011 American Society of Mechanical Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper concerns the optimisation of casing grooves and the important influence of stall inception mechanism on groove performance. Installing casing grooves is a well known technique for improving the stable operating range of a compressor, but the wide-spread use of grooves is restricted by the loss of efficiency and flow capacity. In this paper, laboratory tests are used to examine the conditions under which casing treatment can be used to greatest effect. The use of a single casing groove was investigated in a recently published companion paper. The current work extends this to multiple-groove treatments and considers their performance in relation to stall inception mechanisms. Here it is shown that the stall margin gain from multiple grooves is less than the sum of the gains if the grooves were used individually. By contrast, the loss of efficiency is additive as the number of grooves increases. It is then shown that casing grooves give the greatest stall margin improvement when used in a compressor which exhibits spike-type stall inception, while modal activity before stall can dramatically reduce the effectiveness of the grooves. This finding highlights the importance of being able to predict the stall inception mechanism which might occur in a given compressor before and after grooves are added. Some published prediction techniques are therefore examined, but found wanting. Lastly, it is shown that casing grooves can, in some cases, be used to remove rotor blades and produce a more efficient, stable and light-weight rotor. © 2010 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Casing grooves are known to increase the stable operating range of axial compressors. The mechanism by which this stability enhancement occurs is poorly understood. This paper develops a better understanding of the behaviour of grooves through analysis of new data. An experimental parametric study is used to demonstrate the effect of varying the axial location of a single casing groove on the stability and efficiency of the compressor. The effect that the groove has on rotor outflow blockage, blade loading and the near-casing flow field is then studied using both experimental and computational methods. It is found that the interaction of the groove with the flow field is different when the groove is positioned forward or aft relative to the blade. The interaction of the groove with the flow in the tip region in both of these positions is presented in detail. Finally, the implications of these findings for the design of casing grooves of different depths are discussed. Copyright © 2009 Rolls-Royce plc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using variational methods, we establish conditions for the nonlinear stability of adhesive states between an elastica and a rigid halfspace. The treatment produces coupled criteria for adhesion and buckling instabilities by exploiting classical techniques from Legendre and Jacobi. Three examples that arise in a broad range of engineered systems, from microelectronics to biologically inspired fiber array adhesion, are used to illuminate the stability criteria. The first example illustrates buckling instabilities in adhered rods, while the second shows the instability of a peeling process and the third illustrates the stability of a shear-induced adhesion. The latter examples can also be used to explain how microfiber array adhesives can be activated by shearing and deactivated by peeling. The nonlinear stability criteria developed in this paper are also compared to other treatments. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The operating range of an axial compressor is often restricted by a safety imposed stall margin. One possible way of regaining operating range is with the application of casing treatment. Of particular interest here is the type of casing treatment which extracts air from a high pressure location in the compressor and re-injects it through discrete loops into the rotor tip region. Existing re-circulation systems have the disadvantage of reducing compressor efficiency at design conditions because worked flow is unnecessarily re-circulated at these operating conditions. Re-circulation is really only needed near stall. This paper proposes a self-regulating casing treatment in which the re-circulated flow is minimized at compressor design conditions and maximized near stall. The self-regulating capability is achieved by taking advantage of changes which occur in the tip clearance velocity and pressure fields as the compressor is throttled toward stall. In the proof-of-concept work reported here, flow is extracted from the high pressure region over the rotor tips and re-injected just upstream of the same blade row. Parametric studies are reported in which the flow extraction and re-injection ports are optimized for location, shape and orientation. The optimized design is shown to compare favorably with a circumferential groove tested in the same compressor. The relationship between stall inception type and casing treatment effectiveness is also investigated. The self-regulating aspect of the new design works well: stall margin improvements from 2.2 to 6.0% are achieved for just 0.25% total air re-circulated near stall and half that near design conditions. The self-regulating capability is achieved by the selective location and orientation of the extraction hole; a simple model is discussed which predicts the optimum axial location. Copyright © 2011 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the thermal evolution of end-of-range (EOR) defects in germanium and their impact on junction thermal stability. After solid-phase epitaxial regrowth of a preamorphized germanium layer, EOR defects exhibiting dislocation loop-like contrast behavior are present. These defects disappear during thermal annealing at 400 °C, while boron electrical deactivation occurs. After the whole defect population vanishes, boron reactivation is observed. These results indicate that germanium self-interstitials, released by EOR defects, are the cause of B deactivation. Unlike in Si, the whole deactivation/reactivation cycle in Ge is found to take place while the maximum active B concentration exceeds its solubility limit. © 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents for the first time the performance of a silicon-on-insulator (SOI) p-n thermodiode, which can operate in an extremely wide temperature range of 200°C to 700°C while maintaining its linearity. The thermodiode is embedded in a thin dielectric membrane underneath a tungsten microheater, which allows the diode characterization at very high temperature (> 800°C). The effect of the junction area (Aj) on the thermodiode linearity, sensitivity and self-heating is experimentally and theoretically investigated. Results on the long-term diode stability at high temperature are also reported. © 2013 IEEE.